COST EFFECTIVE MAINTENACE

Slides:



Advertisements
Similar presentations
Surface Engineered Coatings in Pressure Vessels
Advertisements

The second generation of IGCC Power Plants. Problems and solutions.
VORTEX FINDERS (DIP TUBES, IMMERSION TUBES)
Maintenance Shows of America April 2010 Tampa Florida Presented By: Byron Nichols Representing: The American Society of Power Engineers.
Recovery Boiler Modeling
Power Plant Engineering
Heat Recovery Solutions From Fintube Technologies, Inc Date: October, 2008 © United States Steel Corporation.
Objective of equipment maintenance Objective of equipment maintenance Maintenance frequency Maintenance frequency Inspection and Testing Inspection.
Evaluation of Ceramic Coatings for Protection of Piping in High-Temperature, High-Pressure Black Liquor Gasifiers Jim Keiser, James Hemrick, Edgar Lara-Curzio,
Improving power efficiency—why not now?
Anion Performance Chemicals. Scale What is it? How is it costing you money? The Solution - Anion DScale Applications Key Features Major Customers.
A passive investment towards improved control over energy costs.
Dave Stropky, VP Research Process Simulations Ltd East Mall, Vancouver, BC, Canada Industrial Process Modeling.
High Temperature Alloys for Power Plant Applications
Severe Service Metal Seated Ball Valves
Design Steps : Furnace Of A Steam Generator P M V Subbarao Professor Mechanical Engineering Department Selection of Geometric Parameters….
Previous MACT Sub Categories EPA has recognized differences in other industry rules by using sub-categorization: – Differences in processes – Differences.
Summer Co-op Experience: OPG Aditi Garg. Darlington Nuclear G.S Located in Bowmanville, ON.
Dave Stropky, VP Research Process Simulations Ltd East Mall, Vancouver, BC, Canada Industrial Process Modeling.
Heat Exchangers with Cross Flow past Cylinders P M V Subbarao Professor Mechanical Engineering Department I I T Delhi Another Common Industrial Application!!!
AUZIE QUIC SLIP PTY LTD AQS METAL PRO – 001 INTERIOR AND EXTERIOR.
Boiler Tubes.
B OILER Presented by: Muhammad Azffar Mohamad Hanif bin Yusof Nor Aminah bt. Mohd Khalil
Introduction to Heat Exchangers
CORROSION:- TYPES EFFECTS & PREVENTION PRESENTED BY: GAUTAM AHUJA
JC Equipments Pvt. Ltd Heat Exchanger Manufacturers Off Ph : , Tele Fax :
Chapter 12 Characteristics of Ceramic Materials. Objectives Divisions of ceramic – clay and glass. Ceramic stock including synthetic materials such as.
Water Chemistry in Steam Generators: Opportunities for Investigation IAPWS Workshop – Canadian National Committee 11 May 2009.
InsulCorr INSULCORRTM is a high build single component multi polymer acrylic resin matrix coating Incorporates insulating, blocking and reflective agents.
STUDY OF BOILER’S ACCESSORIES
Mechanical Design Of Process Equipment.
MATERIAL CHALLENGES FOR ADVANCED STEAM PLANTS Dr. M. Shekhar Kumar Materials Technology Division Central Power Research Institute Bangalore.
AIM :- TO STUDY ABOUT STEAM POWER PLANT
Yokogawa Indonesia < Document Number> Copyright © 2004, Yokogawa Indonesia PT.YOKOGAWA INDONESIA ENVIRONMENT DIAGNOSTIC ( PART.1.) by Service & Business.
T TNO Environment, Energy and Process Innovation Jaap Koppejan Reducing corrosion and ash deposition in Dutch WtE plants ACERC conference, Feb, Salt.
STEAM POWER PLANTS.
P M V Subbarao Professor Mechanical Engineering Department
Separators Types of Dust Separator Cyclone Separator working & types Critical Parameters Advantages Disadvantages Applications maintenance.
Coal quality issues and options Dr Andrew Minchener OBE General Manager IEA Clean Coal Centre January 2015.
주소 : 경기 성남시 분당구 수내동 트라팰리스 331 호 TEL: FAX: Clean Environment Specialists.
Some University Economizer City Plan: Introduction; Steam generator components; Economizer; Advantages of economizer; Boiler economizer; Сonstruction.
REFINARY & PETROCHEMICAL
MUFFLE FURNACE.
Garland’s Rust-Go System
Gautam Fibre Glass (India) Pvt Ltd
V VENTURI SEPARATORS STEAM.
Methane Cracking CMAT Energy Solutions
Objective 6.02 part 2: Recognize components of construction
Corrosion Control.
BOILER in Pharmaceutical Industry Mr. N. G. Shinde
STEAM CAPACITY UPGRADING FOR BAGASSE FIRED BOILERS
Applied Thermal Engineering
Maniks high efficiency Desuperheater for efficient heat transfer
Maniks Desuperheater a High Performance Energy Saving Product
Desuperheater Best Heat Transfer Device Used In Various Industries
A Train of Closed Feed Water Heaters
PRODUCTS (POWER PLANT)
Furnace Heat Transfer & Steam Generation
Atmospheric Corrosion
BOILER CORROSION 11.1 DEFINITION
PERFORMANCE ANALYSIS OF COMBUSTION SYSTEMS
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
Furnaces (also called Fired Heaters)
Discover Chemical and Materials inspect prerequisites with Market Reports on China
Condensate Recovery Equipment
Boiler Room LOG Sheets: Interpreting the Records
Anatomy & Organs of Power Plant Steam Generators
© 2019 Global Market Insights, Inc. USA. All Rights Reserved Refractories Market Trends Research and Projections for
Heat Transfer analysis of Supercritical SG
Feed Water Treatment for Steam Power plant
Presentation transcript:

COST EFFECTIVE MAINTENACE Edward Lloyd President, CEO Fireside Coatings Corporation Bexxon Global Pte Ltd

Fireside Coating Products Industrial Ceramic Coatings Applications: Boilers, Fired heaters, high temperature process equipment Fireside Coatings Ceramics: Reduce corrosion Fight Erosion Slagging Scaling Thermal efficiency.

INDUSTRIES Power generation Steel manufacturing Pulp and paper Petro-chemical

CERAMIC COATING DEVELOPMENT Development based on over 40 years actual experience applying industrial boilers maintenance coatings Fireside Coatings have deep understanding of the equipment and also the operating conditions that affect equipment performance and reliability.

FIRESIDE CERAMIC CHARACTERISTICS Non toxic Non flammable/water soluble Thermal shock resistant Corrosion/erosion resistant Thermal management coatings Non slagging features

APPLICATION REQUIREMENTS Conventional or Airless spray equipment Applied in thin subsequent coats 50 to 75 microns

APPLICATION Recommended thickness 150-300 microns Coating cures during normal boiler start up

BOILER APPLICATIONS PC Utility boilers CFB boilers BFB boilers Process boilers

PC UTILITY- Maintenance Problems Waterwall slagging and corrosion Superheater and reheater fouling and corrosion Economizer erosion/corrosion Lower slope erosion Nose arch erosion/corrosion

XP61 BOILER & FURNACE COATING Erosion and corrosion resistant Dense, pin hole free surface Stops the diffusion of carbon, oxygen, sulfur into the metal tubing Prevents Coal ash corrosion.

BOILER + FURNACE COATINGS Formula for specific applications XP61-S (reduces slagging and fouling)

XP61-S PC BOILER APPLICATIONS Reheats after XP61-S application

PC BOILER APPLICATIONS Water walls coated with XP61 to provide corrosion protection

TYPICAL CFB/BFB ISSUES Waterwall erosion (refractory interface, cyclone inlet, corners and membrane) Back pass slagging/corrosion Roof and division wall erosion In bed tube erosion

FIRESIDE XP61 BOILER/FURNACE COATING Formulated as XP61-E for erosion resistance

CFB ECONOMIZER TUBES Tube bend erosion = XP61-E

CFB APPLICATION XP61 - Water wall erosion/corrosion

PROCESS BOILERS Waterwall tube erosion/corrosion Superheater fouling and corrosion Economizer erosion Nose arch and roof erosion/corrosion

PULP AND PAPER RECOVERY BOILERS XP61 - Superheater pendants, corrosion, salt cake

RECOVERY BOILERS XP61 - Water wall corrosion

RECOVERY BOILERS Wall studs

PETRO-CHEMICAL REFINERY Fired heaters

OTHER APPLICATIONS XP-61 - Package boiler fire box

REFINERY REF-78 Ceramic fiber insulation Fire Brick /Fiber

APPLICATIONS Fireside TS-511 sealing of stress cracks

APPLICATIONS XP-61 - Steel plant BOF hood

Optēcoat™ is a two color sprayed ceramic coating to protect boiler tubing Also acting as a visual inspection aid. After a long period of operation the two color Optēcoat™ will allow operators and inspectors to visually see any areas of severe erosion or corrosion.

Optēcoat duel color system EROSION/CORROSION

Optēcoat: steam drum tubes EROSION/CORROSION

Optēcoat: after one year run in CFB boiler

Optēcoat one year run in CFB at refractory interface

Fireside Coating customers worldwide use our ceramic coatings to improve performance and extend the life of equipment firesidecoatings.com www.firesidecoatings.com www.bexxonglobal.com info@bexxonglobal.com