The effect of injectable biocompatible elastomer (PDMS) on the strength of the proximal fixation of endovascular aneurysm repair grafts: An in vitro study 

Slides:



Advertisements
Similar presentations
Aneurysm sac pressure monitoring: Does the direction of pressure measurement matter in fibrinous thrombus?  Jan-Willem Hinnen, MD, Daniel J. Rixen, PhD,
Advertisements

Assessment of three-dimensional stent-graft dynamics by using fluoroscopic roentgenographic stereophotogrammetric analysis  Olivier H.J. Koning, MD, Bart.
Late open conversion after endovascular abdominal aortic aneurysm repair  George Kouvelos, MD, PhD, Andreas Koutsoumpelis, MD, MSc, Andreas Lazaris, MD,
Stent-graft repair of traumatic thoracic aortic disruptions
Periscope graft to extend distal landing zone in ruptured thoracoabdominal aneurysms with short distal necks  Zoran Rancic, MD, PhD, Thomas Pfammatter,
Abdominal compartment syndrome associated with endovascular and open repair of ruptured abdominal aortic aneurysms  Chen Rubenstein, MD, Gabriel Bietz,
Effect of type II endoleaks and antiplatelet therapy on abdominal aortic aneurysm shrinkage after endovascular repair  Atsushi Aoki, MD, Takanori Suezawa,
Aortoduodenal fistula 5 years after endovascular abdominal aortic aneurysm repair with the Ancure stent graft  Blaine J. Ruby, MD, Thomas H. Cogbill,
Aortic neck enlargement after endovascular aneurysm repair using balloon-expandable versus self-expanding endografts  Janis Savlovskis, MD, Dainis Krievins,
Direct insertion of Amplatzer plugs to control lumbar arteries during open repair of type II endoleaks  Kimberly Evans, MD, Anne C. Kim, MD, William C.
Peyman Benharash, MD, Jason T. Lee, MD, Oscar J
Results of endovascular repair of infrarenal aortic aneurysms using the Endurant stent graft  Herman J.A. Zandvoort, MD, PhD, Frederico Bastos Gonçalves,
Novel technique for endovascular salvage of a folded aortic endograft
Olivier H. J. Koning, MD, Jan-Willem Hinnen, MD, Jary M
Endovascular repair of abdominal aortic aneurysm in octogenarians: An analysis based on EUROSTAR data  Conrad Lange, MD, Lina J. Leurs, MSc, Jaap Buth,
Role of type II endoleak in sac regression after endovascular repair of infrarenal abdominal aortic aneurysms  Jared Kray, DO, Spencer Kirk, DO, Jan Franko,
Late conversion of aortic stent grafts
David Nabi, MD, Erin H. Murphy, MD, Jimmy Pak, MD, Christopher K
Bruce A. Perler, MD, MBA  Journal of Vascular Surgery 
ITalian Excluder Registry and results of Gore Excluder endograft for the treatment of elective infrarenal abdominal aortic aneurysms  Carlo Pratesi, MD,
Endovascular Aneurysm Repair in the Treatment of Abdominal Aortic Invasion by Metastatic Small Cell Lung Cancer in the Duodenum  Adam H. Korayem, MD,
Physician modification of Gore C3 excluder endograft for treatment of abdominal aortic aneurysms anatomically unsuitable for conventional endovascular.
Kevin J. Bruen, MD, Robert J. Feezor, MD, Michael J
Endovascular abdominal aortic aneurysm repair complicated by spondylodiscitis and iliaco-enteral fistula  Heleen D. de Koning, MSc, Steven M.M. van Sterkenburg,
Techniques in occluding the aorta during endovascular repair of ruptured abdominal aortic aneurysms  Mark Edward O’Donnell, DSEM, MRCS, Stephen A. Badger,
Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing  Dittmar Böckler, MD, PhD, Andrew Holden, MBChB, Matt Thompson,
Sara Rahmani, MSc, Inderraj S
Ricardo Yoshida, MD, Ralf R
Endovascular repair of thoracic stent-graft bulging rupture in a patient with multiple thoracic aneurysms due to Takayasu disease  Guido Regina, MD, Alessandro.
Niyant V. Patel, MD, Graham W. Long, MD, Zulfiqar F
Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: The EUROSTAR experience  Corine van Marrewijk, MSc, Jacob Buth, MD,
Type II endoleak prevention with coil embolization during endovascular aneurysm repair in high-risk patients  Dominique Fabre, MD, Elie Fadel, PhD, Philippe.
Treatment of a type IIIb endoleak in a Talent endograft using telescoping cuffs and two parallel upside-down excluder contralateral legs  Michel M.P.J.
Endovascular repair of an iliac artery aneurysm in a patient with Ehlers-Danlos syndrome type IV  Britt H. Tonnessen, MD, W. Charles Sternbergh, MD, Krishna.
Aortic Customize: A new alternative endovascular approach to aortic aneurysm repair using injectable biocompatible elastomer. An in vitro study  Willem-Maarten.
Explant analysis of AneuRx stent grafts: relationship between structural findings and clinical outcome  Christopher K Zarins, MD, Frank R Arko, MD, Tami.
Thomas S. Monahan, MD, Timothy A. M. Chuter, MD, Linda M
Early endovascular grafts at Montefiore Hospital and their effect on vascular surgery  Frank J. Veith, MD, Jacob Cynamon, MD, Claudio J. Schonholz, MD,
Juan Carlos Parodi, MD  Journal of Vascular Surgery 
Paraplegia prevention branches: A new adjunct for preventing or treating spinal cord injury after endovascular repair of thoracoabdominal aneurysms  Christos.
Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture  Bart E. Muhs, MD,
The effect of endograft relining on sac expansion after endovascular aneurysm repair with the original-permeability Gore Excluder abdominal aortic aneurysm.
Abdulhameed Aziz, MD, Christine O. Menias, MD, Luis A
Philippe Piquet, MD, Philippe Amabile, MD, Gilles Rollet, MD 
Mid- and long-term device migration after endovascular abdominal aortic aneurysm repair: A comparison of AneuRx and Zenith endografts  Britt H. Tonnessen,
First experience using intraoperative contrast-enhanced ultrasound during endovascular aneurysm repair for infrarenal aortic aneurysms  Reinhard Kopp,
Juan Carlos Jimenez, MD, Wesley S. Moore, MD, William J
Successful endovascular repair of a ruptured abdominal aortic aneurysm in a patient with unfavorable anatomy  Benjamin R. Grey, MB. ChB, MRCS, John S.
The upside down Gore Excluder contralateral leg without extracorporeal predeployment for aortic or iliac aneurysm exclusion  Tim J. van der Steenhoven,
Evaluation of the Endurant stent graft under instructions for use vs off-label conditions for endovascular aortic aneurysm repair  Giovanni Torsello,
Chung-Dann Kan, MD, Hsin-Ling Lee, MD, Yu-Jen Yang, MD, PhD 
Endoleakage after stent-graft treatment of abdominal aneurysm: Implications on pressure and imaging—an in vitro study  G.W.H. Schurink, MD, N.J. M. Aarts,
Regarding “Endovascular repair of ruptured abdominal aortic aneurysms”
Sideways displacement of the endograft within the aneurysm sac is associated with late adverse events after endovascular aneurysm repair  Evert J. Waasdorp,
Prospective follow-up of sexual function after elective repair of abdominal aortic aneurysms using open and endovascular techniques  Monica Pettersson,
Mark A. Farber, MD, Robert R. Mendes, MD  Journal of Vascular Surgery 
Totally laparoscopic explantation of migrated stent graft after endovascular aneurysm repair: A report of two cases  Judith C. Lin, MD, Ralf Kolvenbach,
Aortic neck enlargement after endovascular aneurysm repair using balloon-expandable versus self-expanding endografts  Janis Savlovskis, MD, Dainis Krievins,
Secondary interventions following endovascular abdominal aortic aneurysm repair using current endografts. A EUROSTAR report  Roel Hobo, MSc, Jacob Buth,
Relationship between access side used to deliver the main body of bifurcated prostheses for endovascular aneurysm repair and speed of cannulation of the.
Outcome after celiac artery coverage during endovascular thoracic aortic aneurysm repair: Preliminary results  Sarat K. Vaddineni, MD, Steve M. Taylor,
Type B aortic dissection after endovascular abdominal aortic aneurysm repair causing endograft collapse and severe malperfusion  Vikram Iyer, MD, Mark.
Ioannis Prionidis, MD, Tom F. Browne  Journal of Vascular Surgery 
Ronald M. Fairman, MD, Lorraine Nolte, PhD, Scott A
Endovascular repair of stent graft collapse by stent-protected angioplasty using a femoral-brachial guidewire  Drosos Kotelis, MD, Ruben Lopez-Benitez,
John L. Anderson, Donald J. Adam, MD, Michael Berce, David E. Hartley 
Repair of juxtarenal para-anastomotic aortic aneurysms after previous open repair with fenestrated and branched endovascular stent grafts  Donald J. Adam,
Incidence and treatment results of Endurant endograft occlusion
Effect of type II endoleaks and antiplatelet therapy on abdominal aortic aneurysm shrinkage after endovascular repair  Atsushi Aoki, MD, Takanori Suezawa,
Influence of anesthesia type on outcome after endovascular aortic aneurysm repair: An analysis based on EUROSTAR data  Volker Ruppert, MD, Lina J. Leurs,
Presentation transcript:

The effect of injectable biocompatible elastomer (PDMS) on the strength of the proximal fixation of endovascular aneurysm repair grafts: An in vitro study  Willem-Maarten P.F. Bosman, MD, Tim J. van der Steenhoven, MD, Daniel R. Suárez, MSc, Edward R. Valstar, MSc, PhD, Alexander C. de Vries, MD, PhD, Hans L.F. Brom, MD, PhD, Michael J. Jacobs, MD, PhD, Jaap F. Hamming, MD, PhD  Journal of Vascular Surgery  Volume 52, Issue 1, Pages 152-158 (July 2010) DOI: 10.1016/j.jvs.2010.01.026 Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig. 1 Aortic Customize, the treatment concept. Left side depicts the stand-alone therapy (A-F), while the right side depicts the therapy as adjuvance to current EVAR-therapy (G-L). Guide wires are inserted to the aneurysm (B), over which endovascular balloons are inserted to exclude the aneurysm sac from the circulation (C). A fill catheter was inserted next to the balloon, through which the liquid elastomer is injected (D). The elastomer fills every cavity in the aneurysm sac and obliterates lumbar arteries, thereby preventing potential endoleaks (E). When the elastomer has cured (<5 minutes), the endovascular balloon is deflated, leaving the aneurysm excluded with a new lumen (F). As adjuvant therapy (G-I), the process is very similar, whereby the cavities between the graft in an aneurysm sac are filled with the elastomer (J, K), fixating the graft in an elastomer mould of the sac. Journal of Vascular Surgery 2010 52, 152-158DOI: (10.1016/j.jvs.2010.01.026) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig. 2 Schematic drawing of experimental set-up: (A) Sample of bovine artery (45 mm long). (B) Distal fixation plug on which the bovine artery is attached. (C) Artificial aneurysm made of latex (neck 19 mm; widest part 40 mm), which is sutured to the bovine artery (D) A stent-graft inserted in the bovine neck of the aneurysm. (E) Rigid rod with anchor through the endograft, connecting it to the tensile testing machine. (F) Plugs for fixation of the set-up on tensile testing machine. Journal of Vascular Surgery 2010 52, 152-158DOI: (10.1016/j.jvs.2010.01.026) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig. 3 The endoprotheses used in this study: (A) Gore Excluder, (B) Vascutek Anaconda, and (C) Medtronic Endurant. Journal of Vascular Surgery 2010 52, 152-158DOI: (10.1016/j.jvs.2010.01.026) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig. 4 The dislodgement forces (DF) for the different kinds of stent grafts. The bars show mean dislodgement force (n = 5) for the seal length, while the error bars depict the standard deviation (SD). The empty bars show the force needed to dislodge the graft when the aneurysm sac was empty; the striped bars show the forces needed after filling the sac with elastomer. The graph at the right shows that all grafts benefit from the elastomer augmentation. Journal of Vascular Surgery 2010 52, 152-158DOI: (10.1016/j.jvs.2010.01.026) Copyright © 2010 Society for Vascular Surgery Terms and Conditions

Fig. 5 Overview of the setup, the specimens, the grafts, and the elastomer. Inset A shows the setup with a bovine artery with the sutured latex aneurysm. In the artery, a Gore Excluder is placed, which is fixated by elastomer sac-filling. On the top of inset A, the rigid hook is visible on which the graft is attached. The elastomer filling has taken on the exact form of the latex aneurysm with the graft in place (B, E). When the endograft is removed from the elastomer mould, it becomes clear that the elastomer had filled every cavity between graft and sac, leaving casts of the struts of the graft (C). The sharp, rigid hooks for proximal fixation of the Anaconda left distinctive damage to aortic wall, when applying high extraction forces (D). Journal of Vascular Surgery 2010 52, 152-158DOI: (10.1016/j.jvs.2010.01.026) Copyright © 2010 Society for Vascular Surgery Terms and Conditions