Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysis  Takao Ohki, MD, Gary S.

Slides:



Advertisements
Similar presentations
Periprosthetic leak and rupture after endovascular repair of abdominal aortic aneurysm: The significance of device design for long-term results  Kirsten.
Advertisements

Natural history, duplex characteristics, and histopathologic correlation of arterial injuries in a canine model  Thomas F. Panetta, MD, Clifford M. Sales,
Catheter-less angiography for endovascular aortic aneurysm repair: A new application of carbon dioxide as a contrast agent  Enrique Criado, MD, Loay Kabbani,
Giuseppe Lanzino, MD, Alejandro A. Rabinstein, MD, Robert D. Brown, MD 
Arterial rupture without balloon rupture during percutaneous transluminal angioplasty  Timothy P. Murphy, M.D., John J. Cronan, M.D., Landy P. Paolella,
Human transluminally placed endovascular stented grafts: Preliminary histopathologic analysis of healing grafts in aortoiliac and femoral artery occlusive.
Endovascular aortounifemoral grafts and femorofemoral bypass for bilateral limb- threatening ischemia  Takao Ohki, MD, Michael L. Marin, MD, Frank J. Veith,
Sumaira Macdonald, MRCP, FRCR, Graham S. Venables, DM, FRCP, Trevor J
Endovascular grafts for noninfected aortoiliac anastomotic aneurysms
Technique for obtaining proximal intraluminal control when arteries are inaccessible or unclampable because of disease or calcification  Frank J. Veith,
Endovascular techniques for arch vessel reconstruction
Novel sutureless telescoping anastomosis revascularization technique of supra-aortic vessels to simplify combined open endovascular procedures in the.
Intravascular ultrasonography allows accurate assessment of abdominal aortic aneurysm: An in vitro validation study  Jeroen A. van Essen, MD, Aad van.
Impact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysms  Michael L. Marin, MD, Richard E. Parsons,
Catheter-based neurosalvage for acute embolic complication during carotid intervention  Mao-Shin Lin, MD, Ying-Hsien Chen, MD, Chi-Chao Chao, MD, Cheng-Hsin.
Initial results of wireless pressure sensing for endovascular aneurysm repair: The APEX Trial—Acute Pressure Measurement to Confirm Aneurysm Sac EXclusion 
Clinical significance of embolic events in patients undergoing endovascular femoropopliteal interventions with or without embolic protection devices 
Michael L. Marin, MD, Frank J. Veith, MD, Thomas F
Endoleak after endovascular graft repair of experimental aortic aneurysms: Does coil embolization with angiographic “seal” lower intraaneurysmal pressure? 
True lumen re-entry devices facilitate subintimal angioplasty and stenting of total chronic occlusions: Initial report  Donald L. Jacobs, MD, Raghunandan.
Ryan A. Helmick, MD, Charles L. Mesh, MD  Journal of Vascular Surgery 
Shane S. Parmer, MD, Jeffrey P. Carpenter, MD 
Recanalization of flush iliac occlusions with the assistance of a contralateral iliac occlusive balloon  Carlos F. Bechara, MD, MS, Neal R. Barshes, MD,
Scott S. Berman, MD, MHA, FACS, Shonda L. Banegas, DO 
M. R. Sapoval, MD, B. Beyssen, MD, J. Y. Pagny, MD, E
Rafik El-Sabrout, MD, FRCS(G), Denton A. Cooley, MD 
Techniques in occluding the aorta during endovascular repair of ruptured abdominal aortic aneurysms  Mark Edward O’Donnell, DSEM, MRCS, Stephen A. Badger,
Sridevi R. Pitta, MBBS, Gregory W
Aortoscopy: A guidance system for endoluminal aortic surgery
Ex vivo human carotid artery bifurcation stenting: Correlation of lesion characteristics with embolic potential  Takao Ohki, MD, Michael L. Marin, MD,
Periprosthetic leak and rupture after endovascular repair of abdominal aortic aneurysm: The significance of device design for long-term results  Kirsten.
Handmade trileaflet valved stent graft for pulmonary valve implantation  Ting-Wei Lin, MD, MSc, Jieh-Neng Wang, MD, Chung-Dann Kan, MD, PhD, Yu-Jen Yang,
Reese A. Wain, MD, Ross T. Lyon, MD, Frank J. Veith, MD, George L
Clifford M. Sales, MD, Michael L. Marin, MD, Frank J
Endovascular management of ureteroarterial fistula
Juan Carlos Parodi, MD  Journal of Vascular Surgery 
A late complication of internal carotid artery stenting
Objective tinnitus resulting from internal carotid artery stenosis
Richard E. Parsons, MD, Michael L. Marin, MD, Frank J
Duplex–assisted internal carotid artery balloon angioplasty and stent placement: A novel approach to minimize or eliminate the use of contrast material 
Aortic dissection: Percutaneous management of ischemic complications with endovascular stents and balloon fenestration  Suzanne M. Slonim, MD, Ulf Nyman,
Heparin versus bivalirudin for carotid artery stenting using proximal endovascular clamping for neuroprotection: Results from a prospective randomized.
Noritake Akaba, M. D. , Hisashi Ujiie, M. D. , Kazumasa Umezawa, M. D
Harry Spoelstra, MD, Filip Casselman, MD, Olivier Lesceu, MD 
Assessment of carotid artery stenosis by ultrasonography, conventional angiography, and magnetic resonance angiography: Correlation with ex vivo measurement.
Alternative techniques for management of distal anastomoses of aortofemoral and iliofemoral endovascular grafts  Reese A. Wain, MD, Ross T. Lyon, MD,
Efficacy of a proximal occlusion catheter with reversal of flow in the prevention of embolic events during carotid artery stenting: An experimental analysis 
Spontaneous carotid dissection: Duplex scanning in diagnosis and management  Todd F. Early, MD, Roger T. Gregory, MD, Jock R. Wheeler, MD, Stanley O. Snyder,
Embolic risk of the different stages of carotid bifurcation balloon angioplasty: An experimental study  Marc Coggia, MD, Olivier Goëau-Brissonnière, MD,
Repositioning of partially dislodged Greenfield filters from the right atrium by use of a tip deflection wire  Robert B. Patterson, MD, Richard J. Fowl,
Carotid artery closure for endarterectomy does not influence results of angioplasty- stenting for restenosis  Robert W. Hobson, MD, Brajesh K. Lal, MD,
A new approach to carotid angioplasty and stenting with transcervical occlusion and protective shunting: why it may be a better carotid artery intervention 
Endoleaks after endovascular graft treatment of aortic aneurysms: Classification, risk factors, and outcome  Reese A. Wain, MD, Michael L. Marin, MD,
Safer shunt insertion during carotid endarterectomy
Renal failure after embolization of a prosthetic mitral valve disc and review of systemic disc embolization  Thomas H. Schwarcz, M.D., Laurence H. Coffin,
Balloon expandable stents facilitate right renal artery reconstruction during complex open aortic aneurysm repair  Rajendra Patel, MD, Mark F. Conrad,
An experimental study of a new sutureless intraluminal graft with an elastic ring that can attach itself to the vessel wall  Masaru Matsumae, MD, Hatsuzo.
Seizures following subclavian-carotid bypass
Shane S. Parmer, MD, Jeffrey P. Carpenter, MD 
Endovascular repair of abdominal aortic aneurysms in patients with congenital renal vascular anomalies  David B. Kaplan, MD, Christopher C. Kwon, MD,
Transluminal placement of a prosthetic graft-stent device for treatment of subclavian artery aneurysm  James May, MS, FRACS, FACS, Geoffrey White, FRACS,
The effects of endothelial injury on smooth muscle cell proliferation
Long-term experience with transvenous catheter pulmonary embolectomy
G. Pieter Gerritsen, MD, Elma J. Gussenhoven, MD, Salem H. K
Chronic intraaneurysmal pressure measurement: An experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion  Luis.
Carotid body tumor: Atypical angiogram of a functional tumor
Successful cerebral protection during removal of large right atrial thrombus with AngioVac in a patient with patent foramen ovale and recent embolic stroke 
Transfemoral endovascular aortic graft placement
Endovascular repair of two abdominal aortic aneurysms
Richard L. McCann, MD, R.Randal Bollinger, MD, Glenn E. Newman, MD 
Presentation transcript:

Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysis  Takao Ohki, MD, Gary S. Roubin, MD, Frank J. Veith, MD, Sriram S. Iyer, MD, Eamon Brady, PhD  Journal of Vascular Surgery  Volume 30, Issue 6, Pages 1034-1044 (December 1999) DOI: 10.1016/S0741-5214(99)70041-8 Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 1 A, Human carotid plaque specimen. Specimens were removed as plaque casts of carotid bifurcation and were kept circumferentially intact. i, Internal carotid artery; e, external carotid artery; c, common carotid artery; s, superior thyroid artery. B, Expanded polytetrafluoroethylene (ePTFE) wrapped specimen. Distal half of ePTFE graft is cut longitudinally, and plaque is inserted into graft. Redundant ePTFE material covering internal carotid plaque portion is trimmed and sutured (s) . With permission from Ohki T, Marin ML, Lyon RT, Berdejo GL, Ohki M, Soundararajan K, et al. Human ex vivo carotid artery bifurcation stenting: correlation of lesion characteristics with embolic potential. J Vasc Surg 1998;27:463-71. Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 2 Schematic drawing of ex vivo apparatus and bath. Expanded polytetrafluoroethylene covered plaque (CP) is connected to custom-made sheath. This plaque-sheath complex is connected to main port of bath. Saline solution bag raised to 130 cm above the bath is connected to flush channel of main port to maintain continuous flow through lumen of specimen (arrows) . Sheath with three-way valve at proximal end is inserted into center channel of main port, which allows insertion of various endovascular imaging and interventional devices. Effluent is drained through a filter to collect embolic particles generated during endovascular procedure. Orifice of external carotid artery (ECA) is ligated to maintain closed circuit. Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 3 A, Preinterventional ex vivo angiogram. High-grade stenosis is seen in internal carotid artery. External carotid artery (e) is ligated. r, Radiopaque ruler. B, Initial filter guidewire passage through stenosis was accomplished without difficulty, owing to low profile and smooth transition between tip wire and delivery catheter. f, Nitinol-supported filter encased in delivery catheter before deployment. C, Fluoroscopic image after filter guidewire deployment. Nitinol-supported filter (f) is fully deployed in distal internal carotid artery. D, Predilatation of lesion is performed with a coronary balloon under filter protection. E, Wallstent is also deployed under filter protection. F, Completion angiogram shows successful recanalization of internal carotid artery. Flow through filter is preserved. a, Air emboli captured in filter. Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 4 Drawing of MedNova NeuroShield (Horsham, W Sussex, United Kingdom). Filter guidewire is initially encased in low-profile delivery catheter (d) . After delivery catheter retrieval, filter (f) is completely deployed. w, 0.014-in shapeable guidewire; b, bullet providing smooth transition between wire and delivery catheter. Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 5 MedNova NeuroShield (Horsham, W Sussex, United Kingdom). Filtration element has large entry ports at proximal end and multiple perfusion ports (p) at distal end. Filtration element contains pre-shaped nitinol (n) expansion system that assists in filter deployment and in visualization under fluoroscopy. e, Embolic particles. Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 6 Microscopic view of embolic particles released during initial filter guidewire passage. Three small particles consisting of atherosclerotic debris were recovered (filter size, 130 μm; original magnification, × 40). Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 7 A, Close-up view of inside of filter guidewire after carotid artery stenting. Multiple embolic particles have been captured in filter. n, Nitinol frame. B, Microscopic view of embolic particles captured by filter guidewire. These particles consisted of organized thrombus and atheroscrelotic debris (filter size, 130 m; original magnification, × 40). Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 8 Microscopic view of embolic particles that were missed by filter guidewire. Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 9 Size and number of embolic particles released during initial filter passage, those captured by filter, and those missed by filter. Journal of Vascular Surgery 1999 30, 1034-1044DOI: (10.1016/S0741-5214(99)70041-8) Copyright © 1999 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions