réponse d’un détecteur Micromegas

Slides:



Advertisements
Similar presentations
Parallel Ionization Multiplier (PIM) : a multi-stage device using micromeshes for tracking particles MPGD’s Workshop at NIKHEF April 16th2008 April 16th.
Advertisements

Drift velocity Adding polyatomic molecules (e.g. CH4 or CO2) to noble gases reduces electron instantaneous velocity; this cools electrons to a region where.
Time Projection Chamber
Beam tests of Fast Neutron Imaging in China L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang 2, X.
Micromegas studies using cosmic rays Franck Sabatié May 7th 2009 Saclay cosmic ray bench Data acquisition system and analysis tools MIP detection Position.
Maximilien Chefdeville NIKHEF, Amsterdam RD51, Amsterdam 17/04/2008
Beijing, August 18, 2004 P. Colas - Micromegas for HEP 1 Recent developments of Micromegas detectors for High Energy Physics Principle of operationPrinciple.
May 14, 2015Pavel Řezníček, IPNP Charles University, Prague1 Tests of ATLAS strip detector modules: beam, source, G4 simulations.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Micromegas detectors for the CLAS12 central tracker Brahim Moreno (for the Saclay group) CLAS12 technical workshop 03/17/ 2010 Jefferson lab Update on.
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
Micromegas detectors for the CLAS12 central tracker Brahim Moreno (for the Saclay group) CLAS12 central detector meeting : 2 december 2009 Cea Saclay CERN.
Position sensing in a GEM from charge dispersion on a resistive anode Bob Carnegie, Madhu Dixit, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer,
Zerguerras T. – IPNO – RDD – 14/06/2013 RD51 Collaboration Meeting July, Zaragoza 5-6th /12 New results on gas gain fluctuations in a Micromegas.
Measurement of gas gain fluctuations M. Chefdeville, LAPP, Annecy TPC Jamboree, Orsay, 12/05/2009.
Carleton University A. Bellerive, K. Boudjemline, R. Carnegie, A. Kochermin, J. Miyamoto, E. Neuheimer, E. Rollin & K. Sachs University of Montreal J.-P.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
IHEP, Bejing 9th ACFA ILC Physics and Detector Workshop & ILC GDE Meeting The preliminary results of MPGD-based TPC performance at KEK beam.
Linear Collider TPC R&D in Canada Bob Carnegie, Madhu Dixit, Dean Karlen, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer, Alasdair Rankin,
Fabio Sauli-CERN 1 IEEE-NSS Rome 04 F. Sauli, T. Meinschad, L. Musa, L. Ropelewski CERN, GENEVA, SWITZERLAND PHOTON DETECTION AND LOCALIZATION WITH THE.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Chevron / Zigzag Pad Designs for Gas Trackers
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Stanford, Mar 21, 2005P. Colas - Micromegas TPC1 Results from a Micromegas TPC Cosmic Ray Test Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay-
Orsay, January 12, 2005P. Colas - Resistive anode Micromegas1 Dan Burke 1, P. Colas 2, M. Dixit 1, I. Giomataris 2, V. Lepeltier 3, A. Rankin 1, K. Sachs.
Micromegas TPC Beam Test Result H.Kuroiwa (Hiroshima Univ.) Collaboration with Saclay, Orsay, Carlton, MPI, DESY, MSU, KEK, Tsukuba U, TUAT, Kogakuin U,
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
Digital primary electron counting: W, Fano Factor, Polya vs Exponential M. Chefdeville, NIKHEF, Amsterdam RD51, Paris, October 2008.
IHEP, Beijing 9th ACFA ILC Physics and Detector Workshop & ILC GDE Meeting The preliminary results of MPGD-based TPC performance at KEK beam.
Snowmass, August, 2005P. Colas - InGrid1 M. Chefdeville a, P. Colas b, Y. Giomataris b, H. van der Graaf a, E.H.M.Heijne c, S.van der Putten a, C. Salm.
Summer Student Session, 11/08/2015 Sofia Ferreira Teixeira Summer Student at ATLAS-PH-ADE-MU COMSOL simulation of the Micromegas Detector.
S. AUNE 15/09/08 Micromegas Bulk for CLAS12 tracker.
LCTPC meeting, Feb. 11, 2004P. Colas - Micromegas TPC1 Status report of Berkeley- Orsay-Saclay Since Montpellier, we took data with magnetic field, with.
A. SarratTPC jamboree, Aachen, 14/03/07 1 Full Monte Carlo of a TPC equipped with Micromegas Antony Sarrat CEA Saclay, Dapnia Motivation Simulation content.
January 10, 2008MiPGD TPC resolution and gas1 Micromegas TPC addendum on measurements P. Colas, Saclay Lectures at the TPC school, Tsinghua University,
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
Collection of Photoelectrons from a CsI Photocathode in Triple GEM Detectors C. Woody B.Azmuon 1, A Caccavano 1, Z.Citron 2, M.Durham 2, T.Hemmick 2, J.Kamin.
T. Zerguerras- RD51 WG Meeting- CERN - February Single-electron response and energy resolution of a Micromegas detector T. Zerguerras *, B.
A. SarratILC TPC meeting, DESY, 15/02/06 Simulation Of a TPC For T2K Near Detector Using Geant 4 Antony Sarrat CEA Saclay, Dapnia.
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
Durham, Sep 3, 2004P. Colas - Micromegas TPC1 Micromegas TPC Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay- Saclay cosmic setupReminder:
Vienna Conference on Instrumentation – February 27, D. Attié, A. Bellerive, K. Boudjemline, P. Colas, M. Dixit, A. Giganon,
NSCL Proton Detector David Perez Loureiro September 14 th 2015.
E-TCT measurements with laser beam directed parallel to strips Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Mikuž 1,2,
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
Thick-GEM sampling element for DHCAL: First beam tests & more
Max Chefdeville, NIKHEF, Amsterdam
GEM TPC Resolution from Charge Dispersion*
Larger Pixels, New Insights
Micromegas TPC and wire TPC First measurements in a magnetic field
Dipartimento di Fisica, Università del Salento
MDT second coordinate readout: status and perspectives
Large TPCs for HEP ILC-TPC & Fast Neutron detector
Single GEM Measurement
Ioannis Manthos Laboratory of Nuclear & Particle Physics
THGEM: Introduction to discussion on UV-detector parameters for RICH
Numerical simulations on single mask conical GEMs
Ioannis Manthos Laboratory of Nuclear & Particle Physics
Recents Analysis Results From Micromegas TPC
The MICROMEGAS detector in CAST
Avalanche flutuations with InGrid/TimePix
Ionization detectors ∆
PHOTON DETECTION AND LOCALIZATION WITH THE
Dan Burke1, P. Colas2, M. Dixit1, I. Giomataris2, V. Lepeltier3, A
MINOS: a new vertex tracker for in-flight γ-ray spectroscopy
MWPC’s, GEM’s or Micromegas for AD transfer and experimental lines
Pre-installation Tests of the LHCb Muon Chambers
Gain measurements of Chromium GEM foils
Presentation transcript:

réponse d’un détecteur Micromegas à un électron unique   développement d’une source ponctuelle d’électrons présenté par VL à la conférence IEEE-NSS, Hawaii, 29 oct. 2007 B. Genolini , J. Peyré , J. Pouthas , T. Zerguerras service détecteurs, IPN Orsay, France V. Lepeltier, LAL Orsay Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   outline ● introduction ● experimental device: a point-like electron source ● results on: - spatial resolution - energy resolution - single electron response ● conclusion and prospects Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   introduction why a point-like electron source?  in order to characterize and optimize gaseous detectors one needs generally electrons.  usual sources are: - radioactive sources: they produce a well known number of electrons, but without precise spatial and time origin - particle beams: not easy to operate and adjust, and sometimes with large fluctuations (Landau for example)  so a pulsed laser photoelectron source seems to be well suited, since it is potentially: - small in size - adjustable in location, - “ “ time, - “ “ intensity 3 Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   experimental device developed at IPN, Orsay, France intensity tuning beam tuning beam focusing 3D positioning attenuation laminae cylindrical lenses spherical lenses focusing triplet X UV N2 Laser 337nm (~3eV) Z X Y Micromegas electron source ● point-like and adjustable in 3D (accuracy ~1m) ● very small transverse size <100 µm due to the strong focusing and multiphotonic ionization: ~no electrons produced on the micromesh ● adjustable electron population from a few to more than 104 (limitation by discharges) ● very accurate (ns) time synchronization. amplification and detection device quartz lamina with a Ni-Cr 5Å thick deposit (for photo-electron production) d=3 mm E=3kV/cm 125m Ne-iC4H10 90-10 laser 338m anode strips Fe X-ray source golden Mylar foil (for 55Fe calibration) drift 500 lpi Ni mesh 4 Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   registered signals 3D Detector position mesh Laser strip 1 ion collection on the mesh ~100ns T. Zerguerras et al., Xth Vienna Conf. on Instrumentation, Feb 2007, Nucl Instr. and Meth. A581,258(2007) strip 2 strip 3 Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   spatial resolution ● after diffusion photoelectrons are spread over ~3 adjacent pads (pad width/transverse diffusion ~1.5 for the experimental conditions). ● the X transverse position of the source is extracted from the three amplitudes measured on the 3 pads after multiplication of electrons in the Micromegas device (Gaussian fit) ● in principle, for a large enough number of electrons, the spatial resolution is given by: σX2 = σ02 + σdiff2 /Neeff where: σdiff is the total spread of the electron cloud (electron spot size  transverse diffusion experimented by electrons), Neeff the “effective number” of electrons contributing to the signal, σ02 a constant term containing some systematic (electronics, noise etc.) Neeff is expected to be smaller than the total number of electrons Ne, due to fluctuations: - statistical from the production (for example Landau for a MIP) - gain fluctuation from the amplification device ● as an example for a MIP producing ~60 primary electrons multiplied in a Micromegas device, and collected by a pad device, the effective number of electrons is equal to ~25 only (measurements). ● this number may fluctuate depending on the set-up (geometry, electric field, gas mixture, gain, etc.) so it is interesting and important to study the response for a given number of electrons and of course especially for a single electron. 6 Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov 2007

single electron response and energy resolution of a Micromegas detector   spatial resolution - the origin σ0=-1.27+/-0.25 µm is consistent with a zero resolution for an infinite number of electrons. - the slope value 222+/-8µm is consistent with the size of the electron cloud at the anode, calculated from the convolution between:  the source size (<100µm rms)  the transverse diffusion 201+/-2µm, (calculated from Magboltz).  conclusion: no visible degradation of the resolution from fluctuations. spatial resolution (µm) Micromegas gap thickness: 125 µm drift gap: 3 mm strip pitch: 333 µm gas: Ne/Isobutane 90/10 1/√Ne- Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   energy resolution example of ampitude spectrum registered with 1000 laser shots with ~2300 electrons width dominated by the laser fluctuation energy resolution the experimental energy resolution σE/E has been fitted by a quadratic function: (σE/E)2 = a2 + b2/Ne the fitted values of a and b are: - a=7.9 +/- 0.1 % this value could be explained by the fluctuations of the laser intensity and the photoelectron production process, - b=1.17 +/- 0.04 is close to 1, indicating again that the gain fluctuations are small. Micromegas thickness: 125 µm drift gap: 3 mm strip pitch: 333 µm gas: Ne/Isobutane 90/10 1/√Ne- 8 Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   single electron response: method σ ~ 220 m strip width = 333 m σ X0 X method: from a cloud of photoelectrons - well localized in position (Xo) - with a well known population (Ne~200), - and with a well known gaussian spread (σ) we choose a strip located at such a distance from Xo (a few σ) that the mean number of photoelectrons collected on it is less than 1 (mean value < 0.1) and we register the amplitude spectrum. Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   single electron response: an example amplification gap: 50 µm drift gap: 3 mm strip pitch: 338 µm gas: Ne-Isobutane 90-10 gain:40000 (noise ~1000-2000 e) S.E.R Noise (0 electron) preliminary previous measurements at Saclay, J.Derré et al. Nucl Instr. and Meth. A449,314(2004) limitations of the method: 1. laser rate: a few Hz 2. if you want to be sure that you have only 1 electron and no more, in most cases you will have 0 electron  it takes a long time for spectrum registration for typically 104 electrons: ~one hour or more 3. “edge” effect if an electron is amplified near the frontier with the neighbor strip 10 Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   prospects improvements on the experimental device (done): 1. laser: less fluctuation 8%  4% 2. photomultiplier  time information available (ns) 3. more reliable intensity tuning (precise optical attenuators) 4. new multianode readout pad plane, specially designed: single electron signals from a very attenuated laser beam, will be collected on the center of a “large” anode pad (~1mm wide, more than 5 times the electron cloud size), without any edge effect, as previously. 5 cm statistical distribution of single electrons (2D) “large” pad Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007

single electron response and energy resolution of a Micromegas detector   a few words to conclude…  we have developed a point-like photoelectron source, accurately adjustable in position and intensity.  this source has been successfully experimented for energy and position resolution studies of a Micromegas.  with this source it is possible to study the single electron response of a(ny?) MPGD device.  in the next future, after recent improvements, this electron source will be used for more systematic detector characterization tests, especially on SER, with different gas mixtures and pressures, gain ,etc. Vincent Lepeltier, LAL, Orsay, réunion SOCLE, Clermont-Ferrand, 19-20 nov. 2007