MRI Safety Training.

Slides:



Advertisements
Similar presentations
Introduction to RF for Accelerators
Advertisements

Ag Mechanics Part I. Careers in Ag Mechanics Attracts students interested in ___________, ___________, service and selling of agricultural equipment Varied.
YOUR GUIDE ON MRI.
RESEARCH MRI Safety Training
MRI Phillip W Patton, Ph.D..
1 of 24 CCS&BS MR Safety SeminarCenter for Complex Systems and Brain Sciences Magnetic Resonance Safety Seminar: An Introduction to the Potential Hazards.
MRI Safety This slide show will educate all healthcare providers about the safe delivery of care in the magnetic resonance (MR) environment. This slide.
RESEARCH MRI Safety Training
WHAT IS SUPERCONDUCTIVITY?? For some materials, the resistivity vanishes at some low temperature: they become superconducting. Superconductivity is the.
CONTROL OF HAZARDOUS ENERGY “LOCKOUT/TAGOUT” (LOTO)
MRI Safety. Magnet Type  The MRI magnet used at MCH is the superconducting type. Superconducting magnets use a special wire which loses all resistance.
Two-mode Safety and Battery System Service
Basic Nitrogen Safety Course San Juan College Regional Energy Training Center.
MRI Safety Jeopardy* ForcesProjectilesPotpourriHeatingScreening Because when you think MRI safety, think * Jeopardy is a trademark of Sony.
Equipment Magnetic resonance imaging (MRI) scan requires the use of a very strong magnetic field. Unlike other devices used in radiology, MR imaging.
MRI Safety Jeopardy* EnteringMagnetsPotpourriMetalScreening Because when you think MRI safety, think * Jeopardy is a trademark of Sony Digital.
Overview The scanner Dangers in around the scanner In case of an emergency Emergency numbers Emergency procedure Reporting adverse events Safety checklists.
FMRI: Biological Basis and Experiment Design Lecture 18: Physical practicalities Digression: analysis ICE9: Example for WA8 Safety limits –dB/dt –SAR –Acoustic.
Chapter 21 Magnetism SPS10. Students will investigate the properties of electricity and magnetism. c. Investigate applications of magnetism and/or its.
Magnetic Resonance Imaging Mary Holleboom ENGR 302 May 7, 2002.
THE MAGNETIC FIELD IS AT FULL POWER ALWAYS …. IT IS ALWAYS “ON”.
MRISC Organizational Chart Research and Graduate Studies Dr. James Tracy College of Medicine Fred de Beer, M.D. Director Dr. Charlie Smith Administrative.
MRI SAFETY FOR NON-MRI PERSONNEL.
MRI Safety Wendy Winkle
Biomagnetism By Dr. Amr A. Abd-Elghany. Magnetism Magnetism is a fundamental property of matter; it is generated by moving charges, usually electrons.
Lockout - Tagout Control of Hazardous Energy CFR
Magnetic Resonance Imaging
Chapter 15: MRI Safety Mark D. Herbst, MD, PhD. Two main sources of danger Magnetic field RF Energy Also –Gradients –Acoustic noise.
Medical Imaging Technology “Brainstorm” different types.
The UE directive 2004/40/EC and Magnetic Resonance Imaging a debate Thierry Metens Ph D Université Libre de Bruxelles, Hôpital Erasme Brain awareness week.
PC Maintenance: Preparing for A+ Certification Chapter 2: Safety and Preventive Maintenance.
Medical Imaging Technology
Magnetism Physical Science. What is a magnet?  2000 years ago the Greeks discovered a mineral that attracted things made of iron.  They named this mineral.
Uniting MRI with ULTRASOUND hhholdorf. Dr. Raymond Damadian The MRI scanner was invented by Raymond Damadian. Though, Damadian did not invent the actual.
Lock-Out / Tag-Out Types of Energy Types of Energy Electrical Electrical Mechanical Mechanical Chemical Chemical Thermal Thermal Hydraulic Hydraulic.
Chapter 17 & 18 Discovery Notes.
Electricity and Magnetism Module 6. What is electricity? The collection or flow of electrons in the form of an electric charge.
Chapter 22 Magnetism and Its Uses.
 “e-bomb” video (1:19) “e-bomb” video (1:19) 
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
MRI Safety Course Module 5- Magnetic Fields and Radiofrequency.
Human Subjects in fMRI Research Credits: Robert Savoy, Ph.D. Franz Schmitt, Ph.D.
Magnet Safety.
Lockout - Tagout Control of Hazardous Energy OSHA Standard
Chapter 22 Magnetism and its uses Characteristics of Magnets Greeks experimented more than 2000 years ago with a mineral that pulled iron objects.
Medical Imaging Technologies
To return to the chapter summary click Escape or close this document. glencoe.com Image Bank Foldables Video Clips and Animations Standardized Test Practice.
Copyright © 2012 American Safety Management Inc. Lockout Tagout.
NMR Safety Powerful magnets. NMR Safety 2 NMR Safety Information. UMBC Dept. of Chemistry and Biochemistry. Accessed 7 Jan 2014.
Electricity and Magnetism
 This depends on a property of nuclei called spin.  Gyroscope: Principle: As long as its disc remains spinning rapidly the direction of the spin axis.
Catalyst: Given, Un Known , equation &Solution must be shown.
Medical Resonance Imaging
For First Responders, Facility &
MRI Safety Awareness The purpose of this healthstream presentation is to educate the hospital staff that do not routinely come into the MRI environment.
Methodist Hospital for Surgery
Jody Culham Brain and Mind Institute Department of Psychology
Mechanical Power Press Safety
Medical Imaging Imagining Modalities.
MRI Student orientation
Magnetic field safety October 2018.
Basics of MRI By Dr. Mohamed Samieh.
Human Subjects in fMRI Research
Center for Magnetic Resonance Research
Mechanical Power Press Safety
Chapter 21 Magnetism.
Hoglund Brain Imaging Center
College of Dental Medicine
Superconducting Magnets
Presentation transcript:

MRI Safety Training

  Safety Background The MRI scanner is a very large and powerful magnet Most clinical scanners are 1.5 - 3 Tesla scanners 3 Tesla = 30,000 gauss Earths magnetic field ~ 0.5 gauss

MRI SAFETY Magnetic Resonance Imaging (MRI) is one of the most powerful medical diagnostic technologies, combining strong magnetic fields with powerful computer image processing.

Function The core of an MRI machine is a very high-strength magnet arranged to surround most of the patient's body. This magnet is usually wrapped with coils of copper wire, and when electricity flows through the wire a powerful magnetic field is produced.

Significance In normal MRI machines, the magnets are superconducting---their wires have zero resistance to the flow of electric current. The only way to achieve superconductivity is to make the magnets ultra-cold by submerging them in liquid helium: at about -453 °F, the magnet assembly is barely 5°F above absolute zero. Often, this liquid helium is surrounded by an insulating blanket of liquid nitrogen. Because superconducting wires continually conduct and recalculated the electric current without resistance, the magnetic field is present 24 hours a day; whether the MRI machine is being used or not.

Considerations Safe operation of an MRI machine requires managing three main categories of potential safety issues, all addressed by MRI safety training programs: 1. Medical/biological effects of high-strength magnets 2. Area/vicinity effects of high-strength magnets 3. Cryogenic (ultra-cold) gases

Biological magnetic issues There's no evidence indicating biological side effects from the magnetic fields of an MRI scan, and MRI machines don't utilize any ionizing radiation that can damage cells or DNA. Pregnant patients and technicians are generally advised to avoid MRI during the early months of pregnancy, due to a lack of research on potential magnetic effects on the developing fetus. MRI operators are trained on pregnancy safety guidelines.

Magnetic object safety The main potential danger from MRI machines comes from the interaction of the magnetic field with metallic objects or particles. Any metal inside the patient (such as medical devices or shrapnel) can cause severe injuries. Metallic objects in the vicinity of an MRI room can be attracted by the "fringe" magnetic field---causing them to be sucked into the MRI machine at high speed, posing a severe danger to patients. MRI training videos demonstrate this threat. MRI safety training outlines the methods of screening for potentially hazardous metal in a patient's body, and for preventing the entry of any ferromagnetic objects into the MRI room.

Potential Projectiles: Examples Cell phone Keys Glasses Hair pins / barrettes Jewelry Safety pins Paper clips Coins Pens Pocket knife Nail clippers Steel-toed boots / shoes Tools Clipboards No loose metallic objects should be taken into the Scan room!

Remember, the magnet is ALWAYS on! Even when the MRI Scanner is not in use, the magnet is on. Ferromagnetic objects should NEVER be taken into the Scan Room.

Cryogenic safety MRI operators are trained in the safe management of cryogenic equipment and gases. In the event of a rapid boil-off of the liquid nitrogen or liquid helium surrounding the magnet (a "quench"), a failure of the emergency venting system can cause a life-threatening oxygen shortage in the MRI room. MRI safety training includes preparation for unplanned and emergency quench conditions with vent malfunction. Additionally, operators are trained in emergency shutdown procedures short of a damaging quench---which is typically only initiated if a patient's life is threatened by a foreign metallic object.

Hearing Protection in the MR A characteristic of the switching gradient fields is the production of acoustic noise. When the alternating low-frequency currents flow through the gradient coils, which are immersed in the high static magnetic field , forces are exerted on the gradient coils that move like a loudspeaker coil and generate sound waves. The level of this acoustic noise at the location of the subject or volunteer can reach an unacceptable and even dangerous level. All personnel (MRI Technician, research group member, volunteer subject, family member, etc.) are required to wear hearing protection in the magnet room while the scanning procedure is being performed.

Additional training issues Operators may also be trained in responding to medical emergencies during an MRI scan; fire and evacuation procedures; and hearing protection and communication during the often-noisy scanning process.

Safety Issue of Static Magnetic Field All non-MR personnel & study subjects entering the MRI scanner room must be screened. ACR recommends that non-emergent patients should be screened by two separate individuals. Consider using plain-film radiographic study to confirm the absence of metal fragments in critical parts of the body.

Safety Issue of Static Magnetic Field Zones Zone 1: Reception area Zone 2: Screening interview area Zone 3: Control area, access restricted with key locks, passkey systems etc. Zone 4: MR scanner room MR personnel must have safety training, non-MR personnel cannot have independent access to Zone 3 or 4.

Biological Effect of Radiofrequency Field (1) Radiofrequency energy deposited in the body during an MR examination will be converted into heat. ‘Specific Absorption Rate’ (SAR) is defined as the average energy dissipated in the body per unit mass and time. This heat gain is countered by heat loss through sweat glands and cutaneous blood vessels.

Thermal Safety of Subject Resonant circuitry can result in heating of the tips of wires or leads to temperature in excess of 90 deg C within a few seconds All unnecessary electrically conductive materials should be removed before imaging. All attached leads should be covered with cold compress or ice pack. Avoid any large conductive loops, including limbs(do not cross arms or legs in the MR, this forms a loop as well). Care should be taken to place thermal insulation between the subject and electrically conductive material.

Only items marked “MR Safe” are permitted in the magnet room Only items marked “MR Safe” are permitted in the magnet room. If there is a question concerning the MR safety aspect of any item—do not allow it to be brought into the magnet room!

Magnet Room Acceptability Labels MR SAFE an item which poses no known hazards in all MR environments MR UNSAFE an item which is known to pose hazards in all MR environments. MHRA DB2007(03) December 2007 MR CONDITIONAL An item which has been demonstrated to pose no known hazards in a specified MR environment with specified conditions of use. Field conditions that define the specified MR environment include field strength, spatial gradient, dB/dt (time rate of change of the magnetic field), radio frequency (RF) fields, and specific absorption rate (SAR). Additional conditions, including specific configurations of the item, may be required.

The End