New developments in photodetection

Slides:



Advertisements
Similar presentations
Introduction This project used cosmic rays to test a prototype Minimum Bias Trigger Scintillator (MBTS) that will be used in the ATLAS experiment at CERN.
Advertisements

The performance of Strip-Fiber EM Calorimeter response uniformity, spatial resolution The 7th ACFA Workshop on Physics and Detector at Future Linear Collider.
TileCal Electronics A Status Report J. Pilcher 17-Sept-1998.
Beam Loss Analysis Tool for the CTF3 PETS Tank M. Velasco, T. Lefevre, R. Scheidegger, M. Wood, J. Hebden, G. Simpson Northwestern University, Evanston,
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
ECAL electronics Guido Haefeli, Lausanne PEBS meeting 10.Jan
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Leroy Nicolas, HESS Calibration results, 28 th ICRC Tsukuba Japan, August Calibration results of the first two H·E·S·S· telescopes Nicolas Leroy.
Status of scintillator KLM study P. Pakhlov (ITEP)
PMF: front end board for the ATLAS Luminometer ALFA TWEPP 2008 – 19 th September 2008 Parallel Session B6 – Programmable logic, boards, crates and systems.
Anatoli Konoplyannikov Design and integration of HV, LED monitoring and calibration system for HCAL Overview of the subsystems design High voltage.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
VC Feb 2010Slide 1 EMR Construction Status o General Design o Electronics o Cosmics test Jean-Sebastien Graulich, Geneva.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
CALORIMETER system for the CBM detector Ivan Korolko (ITEP Moscow) CBM Collaboration meeting, October 2004.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Design and optimization of Electromagnetic particle Detectors (EDs) in LHAASO-KM2A Xiangdong Sheng, Jia Liu, Jing Zhao on behalf of the LHAASO collaboration.
CS TC 22 CT Basics CT Principle Preprocessing. 2 CT Basics CT principle preprocessing CS TC 22 Blockdiagram image processor.
R. Pani Department of Experimental Medicine and Pathology University of Rome La Sapienza-Italy. Flat Panel PMT: advances in position sensitive photodetection.
Catania 11 ICATPP october, 2009 Como 1/12 Catania Comparative measurements of the performances of four super bialkali large.
The RICH Detectors of the LHCb Experiment Carmelo D’Ambrosio (CERN) on behalf of the LHCb RICH Collaboration LHCb RICH1 and RICH2 The photon detector:
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
R&D of Calorimeter using Strip/Block Scintillators with SiPM
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
RICH meeting, F.Muheim1 Proposal for MAPMTs as Photodetectors for the LHCb RICH Franz Muheim University of Edinburgh on behalf of the MAPMT group.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
S.MonteilPS COMMISSIONING1 MaPMT-VFE-FE ELECTRONICS COMMISSIONING AND MONITORING. OUTLINE 1)Ma-PMT TEST BENCHES MEASUREMENTS 2)VFE AND FE ELECTRONICS FEATURES.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
E. Picatoste, D. Gascon PMT afterpulsing and SPD trigger 1 Looking to the problem from the instrumentation point of view LHCb Calorimeter Meeting – CERN.
Sergey BarsukElectromagnetic Calorimeter for 1 Electromagnetic Calorimeter for the LHCb experiment Perugia, Italy March 29 – April 2, 2004 ECAL CALO Sergey.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
M.D. Nov 27th 2002M0' workshop1 M0’ linearity study  Contents : Electronic injection Laser injection Beam injection Conclusion.
The photomultiplier tubes selection for KM2A electromagnetic particle detectors (EDs) hou chao IHEP The 2nd workshop of air shower detection at high altitudes.
Michael Lindgren 1 Off-Axis Workshop March 13, 2003 CDF R5900 MAPMT Experiences l Outline wCDF usage wTesting wPerformance wComments l Not sure what to.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
KM2A PMT testing platform FENG Cunfeng, LI Chaoju, SUN Yansheng Shandong University THE 2 nd WORKSHOP OF AIR SHOWER DETECTION AT HIGH ALTITUDES IHEP, Beijing,
 13 Readout Electronics A First Look 28-Jan-2004.
1 SuperB-PID, LNF 4/4/2011 MAPMTsSilvia DALLA TORRE COMPASS experience with HAMAMATSU MAPMTs S. Dalla Torre.
Development of Multi-Pixel Photon Counters (1)
The dynamic range extension system for the LHAASO-WCDA experiment
PreShower Characterisations
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Commissioning of the Crystal evaluation setup
The High Dynamics Readout of PMT for BGO Calorimeter
Scintillation Detectors in High Energy Physics
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
Increasing the Spatial Resolution of the Tile Calorimeter
A First Look J. Pilcher 12-Mar-2004
CMS ECAL Calibration and Test Beam Results
CLAS12 Forward Detector Element PCAL
Particle Identification in LHCb
LHCb calorimeter main features
Instrumentation for Colliding Beam Physics 2017
The Pixel Hybrid Photon Detectors of the LHCb RICH
Directional Optical Module Integration
Multianode Photo Multipliers for Ring Imaging Cherenkov Detectors
Department of Physics and Astronomy,
Времяпролетный детектор PANDA
Development of hybrid photomultiplier for Hyper-Kamiokande
Pre-installation Tests of the LHCb Muon Chambers
Photomultiplier (PMT) Tubes
How can we study the magnetic distortion effect?
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

New developments in photodetection 3rd Beaune conference New developments in photodetection lhcblogo.gif Study of Multi Anodes Photomultipliers for the PreShower read out of the LHCb experiment Olivier Deschamps On behalf of the LPC CLERMONT-FERRAND LHCb group O.Deschamps MAPMT Study

The PreShower is of major importance for the first trigger level lhcblogo.gif The Large Hadron Collider beauty experiment High energy Physics detector aiming at understanding the origin of the matter/anti-matter asymmetries in the universe. LHCb 20 meters long spectrometer on the Large Hadron Collider at CERN First data expected for 2007 Efficient trigger able to cope with the 40 MHz LHC beam frequency The PreShower is of major importance for the first trigger level O.Deschamps MAPMT Study

About hundred 64-Anodes PMTs perform the Read Out of the lhcblogo.gif The LHCb PreShower One centimeter thick lead sheet as radiator in front of a 6000 cells scintillator wall. About hundred 64-Anodes PMTs perform the Read Out of the 6000channels. Cells are grouped by block of 64, forming a preshower module. Scintillation light is extracted from the plastic cells with 1mm thick helicoidal Wavelength Shifting Fibres. Both WLS fibres ends are connected to long clear fibres. Each cell is read out through one channeof a 64-Anodes PMT. O.Deschamps MAPMT Study

A test bench has been developed for the MultiAnode PMT studies lhcblogo.gif The PreShower Read Out 8x8 matrix of fibres connects the 64 preshower channels to the 64 Anodes of a PhotoMultiplier Tube ASIC specially designed Perfect 40MHz integrator more details in the poster session I H7546 from Hamamatsu A test bench has been developed for the MultiAnode PMT studies O.Deschamps MAPMT Study

Purposes of the test bench Description of the experimental setup Outline Purposes of the test bench Description of the experimental setup Protocol – stability checks Results : linearity measurements gain measurements anode uniformity measurements cross-talk features Conclusions and perspectives O.Deschamps MAPMT Study

Purposes Of The Test Bench FEATURES ADRESSED IN THIS TALK Linearity: The PreShower has to detect Minimim Ionizing Particles (20-30 photoelectrons) and to measure electromagnetic shower energy deposit (up to 100 MIPs) A 10 bits dynamics is required for PreShower. The photomultiplier response required to be linear over the whole range Anode uniformity of the response: Same supply voltage for the 64 channels. The gains must (will) be adjusted by dedicated load resistors on the very front-end card. However non-uniformity must be in the larger ratio (1:3). Uniformity of the response within one channel: this information may serve the adequate design of the connectic geometry fibre/PMT. Cross-talk between the PMT channels: a large signal on one channel should not induce fake signal for adjacent channels. The cross-talk must be of the order of 1 % O.Deschamps MAPMT Study

Experimental Setup - Global Sketch O.Deschamps MAPMT Study

mimics the PreShower signal satisfactorily Experimental Setup – the Light Sytem (1) FILTER LED 2.5 cm OPTICAL QUARTZ FIBRE µ-LENS OPTICAL COUPLER BALL LENS 3 mm MonoAnode PMT as reference Studied MultiAnodes PMT Light signal shape Test Bench Signal (5ns Diode Voltage Pulse) PreShower signal from cosmics mimics the PreShower signal satisfactorily O.Deschamps MAPMT Study

Experimental Setup – the Light Sytem (2) Fibre Active Core 200 µm THE LIGHT SYSTEM DESIGN O.Deschamps MAPMT Study

Experimental Setup – the Light Sytem (3) CHARACTERISTICS OF THE FILTER Linear in optical density up to D=3 D = log (1/T) Light attenuation up to a factor 103 The filter displacement is motorised The step resolution is about 20 µm. 90 % of the dynamics is covered in 1/3 of the whole distance. A lot of points are available at very small light yield. O.Deschamps MAPMT Study

Experimental Setup – PM Support System DESIGN OF THE PM TABLE The PMT moveswith respect to the optical fibre position thanks to a x/y-translation-motorised table . The step resolution is again about 20 µm. Meant to allow fine structure tests of PMT window. O.Deschamps MAPMT Study

Experimental Setup – Monitoring and Acquisition MONITORING BY LABVIEW: PM HV Supply PM displacements in (x,y) Optical filter displacements HAND MONITORING : The diode voltage The pedestal mode READ OUT: 12 bits CHARGE ADC Lecroy Acquisition Monitored With Labview MEASUREMENTS : Result from the mean and sigma of gaussian fit to the charge distribution from the PM response. Number of photo-electrons as O.Deschamps MAPMT Study

Protocol stability checks Light yield stability Reference monoanode PMT R5900 Atlas-Tilecal-like is used The light is found stable within ± 1% Thenumber of photon-electrons is gaussianly distributed with sigma at 6% Pedestal stability Pedestal spread is found to be around one ADC channel. Stable along the operation time within 0.1 ADC channels Stable with High Voltage variations within 0.2 ADC channels. Optical coupling stability The light spot size on the filter is 3mm wide and logarithmically distributed Two reference monoanode PMTs are used to chec the coupling ratio stability Stable within few per mil for 90% of the dynamics. Linearity measurements with a reference PMT possible in this range O.Deschamps MAPMT Study

RESULTS (1) – the Linearity METHOD : make vary the attenuation – 50 measurements. Suppose the PMT is linear in the region of very high attenuations; fit of a straigth line to the response and compute the deviation to the expected linearity. O.Deschamps MAPMT Study

RESULTS (1) – the Linearity CONVERSION CHARGE-CURRENT : suppose a triangular signal shape and measure the time half width. O.Deschamps MAPMT Study

RESULTS (1)– the Linearity CONCLUSIONS : There are several ways to express the linearity of the PMT response. The MA64 PMT is linear (within 5%) up to 100 photoelectrons at 850 V. The MA64 PMT is linear (within 5%) up to 2000 photoelectrons at 650 V (expected working voltage). Convenient way to compare with the electronics board design : a deviation to the linearity at the 5 % level is observed for a maximal current at the anode of about 1 mA. Covers satisfactorily the whole dynamics range. O.Deschamps MAPMT Study

RESULTS (1) – the Linearity Reference PM Channel 1 fired EFFECT OF THE SATURATION OF ONE CHANNEL ON THE OTHERS METHOD : Make use of the optical Cross-Talk between channels. Fibre is 1mm far from the PM window No effect of a saturating channel on others. SATURATION IS A LOCAL PHENOMENON O.Deschamps MAPMT Study

RESULTS (2) – the Gain Measurement METHOD : make vary the supply voltage of the PMT by step of 25V Nice fit of the power law Q=aVb for the PM64 up to HV = 900V  (limit of a linear response). O.Deschamps MAPMT Study

RESULTS (3) – the anode uniformity METHOD : measure the geometry of the PM window Fibre displacements of 200µm steps (by-product : the uniformity of the PM response within one channel). The pixels are set regularly similar answer between pixels double structure; dissymmetry x/y (this image of the PMT window is consistent with the physical view)  FIBRE CONNECTION border effects dissymmetric (negligible in x, huge in y) O.Deschamps MAPMT Study

RESULTS (3) – the anode uniformity As an illustration of the test bench facility, gain uniformity measurements for the 64 channels of the Flat Panel PMT from HAMAMATSU studied in LPC from the purpose of medical imaging Dispersion less than a factor 3 12 channels of the M64 APMT O.Deschamps MAPMT Study

RESULTS (3) –anode uniformity within a pixel METHOD : displace the PMT by step of 100 µm and measure the response.  FIBER AT 200 µm FROM PMT WINDOW FIBER AT 1000 µm FROM PMT WINDOW  Evidence of a double structure - intuitively dictated by the first look at the PM window - but strongly dissymetric. When the fibre is moved back, light is averaged and there is a useful surface large in X, thin in Y. O.Deschamps MAPMT Study

RESULTS (3) – the anode uniformity CONCLUSIONS The measured pixels are set regularly The maximum of the PMT answer is dissymmetric in x and y  may serve the design of the FIBRE CONNECTION There are border effects again dissymmetric  may serve the design of the FIBRE CONNECTION Variation from one channel to the other (less than 3) within the electronics gain correction requirements so far. Non-uniformities occur in the multiplication chain O.Deschamps MAPMT Study

RESULTS (4) – Cross-Talk METHOD : the fibre is 100µm far from the PM window fire a central pixel and measure the 8 neighbours charge result is normalised to the central value two channels measured Basically NO INTRINSIC CROSS-TALK between the PMT channels O.Deschamps MAPMT Study

Conclusions the MultiAnodes PMT test bench is in successful operation First results addressed: gain measurements anode uniformity measurements linearity measurements cross-talk features MA64 PMT corresponds so far to the PreShower requirements O.Deschamps MAPMT Study

More details in a dedicated poster : Perspectives Perform short and long term stability tests. In particular check the aging behaviour that could be crucial in the concern of the LHCb hostile environment. Test other candidates : XP1700 (Photonis), M16 et M64 (six dynode stages) HAMAMATSU Multi-elements APD array Perform the acquisition with the LHCb PreShower full electronics chain developped. More details in a dedicated poster : « ReadOut system for the LHCb PreShower », LPC/LHCb, Session I O.Deschamps MAPMT Study

Acknowlegements O.Deschamps MAPMT Study

Number Of Photoelectrons: Protocol test : light yield stability check Reference monoanode PMT R5900 Atlas-Tilecal-like are used The light is found stable within ± 1% Light yield variation (9 hours run) Number Of Photoelectrons: Gaussianly distributed  6% fluctuation O.Deschamps MAPMT Study

Protocol test :pedestal stability check METHOD : pedestal measurement from the diode trigger, varying the HV and the operation time. Pedestal spread is found to be around or less than one ADC channel. Pedestal mean value is stable along the operation time within 0.1 ADC channels Pedestal mean value is stable with HV variation (500V to 900V) within 0.2 ADC channels. O.Deschamps MAPMT Study

Protocol test :optical coupling stability 2 reference R5900 PMTs THE OPTICAL COUPLING The light spot size on the filter is 3mm wide. The filtered light is then dissymetric and logarithmically distributed. It is likely that the optical coupling is sensitive to the opening angle of the light from the fibre. If the initial spread is conserved, the coupling ratio R could be erratic. Significant effect is observed in the region of transition between full transparency and active part of the filter. Flat answer within few per mil for 90% of the dynamics. Linearity measurements with a reference PMT possible in this range. O.Deschamps MAPMT Study

Results – The Linearity CROSS-CHECK : THE SHAPE DISTORTION IMAX = 0,8 mA 5% deviation O.Deschamps MAPMT Study

Results – Anode Uniformity is the non-uniformity related to the photocathode or the multiplication system ? CONCLUSION : no correlation between Npe and the response. Also supported by the gain studies. O.Deschamps MAPMT Study

Purposes Of The Test Bench (2) FEATURES NOT ADRESSED IN THIS TALK Gain measurements and calibration Short and long term drift Dark current Measurements with few photo-electrons Everything we did not think about yet O.Deschamps MAPMT Study