Fundamental Techniques and Measurements

Slides:



Advertisements
Similar presentations
Lab equipment. Triple-beam balance Used to measure mass (in grams) Make sure all balances are at 0 and the scale is pointing to 0 prior to using Place.
Advertisements

Stoichiometry: Quantitative Information about chemical reactions.
Error Analysis. As a scientist you must make the best effort to avoid errors! Errors may be present in: - the design of the experiment. -the use of instruments.
Basic Laboratory Skills
بسم الله الرحمن الرحيم UMM AL-QURA UNIVERSITY Faculty of Medicine Dep. Of BIOCHEMISTRY.
Fundamental Techniques and Measurements  Mass Measurements  Volume Measurements  Preparation of a solution of known concentration  UV-Visible Spectrophotometer.
Fundamental Techniques and Measurements
Common Laboratory Glassware and Volumetric Glassware Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
Lecture 2b. Electromagnetic Spectrum Visible range: = nm Ultraviolet: = nm Low energyHigh energy.
Introduction to the most commonly used glassware and equipments in the lab.
Determination of Iron in Water
Pre-Lab Talk Thompson Rivers University
Dilution 2003 Required D. Information Given A student is instructed to determine the concentration of a solution of CoCl 2 based on absorption of light.
SPECTROPHOTOMETRY. Determines concentration of a substance in solution by Measures light absorbed by solution at a specific wavelength by using spectrophotometer.
Identification of the common laboratory glassware, pipettes and Equipment . BCH 312 [PRACTICAL]
Fluorometric determination of riboflavin
Fluorometric determination of riboflavin. Introduction.
Solutions & Solubility
Mastering the micropipette. What is a micropipette? How do you use a micropipette? How can I determine if I’m pipetting correctly?
(Introduction ,The Equipment ,The Process , Calculations )
SPECTROPHOTOMETRY. Principle : there is interaction between the light and sample particle, spectrophotometer is employed to measure the amount of light.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Preparing Solutions.
Unit 4 : Solutions 8.4 – Dilution and Solution Preparation.
SPECTROPHOTOMETRY PRACTICAL 213 PHC INSTUMENTAL ANALYSIS.
Solutions & Solubility Solution Preparation. Solution Preparation from a solid  Standard Solution = a solution for which the precise concentration is.
Experiment 33 Colorimetric Determination of Iron CHE1181.
Fluorometric determination of riboflavin
Experiment: Solutions Preparation, Part 1 1CHE116.
Uncertainty and error in measurement
General Laboratory Techniques Dry Lab Chemistry 1105.
LAB. S2: Spectrophotometric Determination of Indomethacin/Salicylic Acid Mixture.
Absorption spectrum and spectrophotometric determination of concentration Experiment 1.
枣庄学院化学化工与材料科学学院 Preparation of Solution. 枣庄学院化学化工与材料科学学院 1. Grasp the basic Method and Operation of Preparing Solution 2. Study the Method of Use about.
Introduction to Lab Techniques Measurements and Calibration.
Chemistry 20  A standard solution is any solution whose concentration is accurately known.  Dilution involves the addition of solvent to a solution.
Fundamentals of Analytical Chemistry Eighth Edition.
Topic 11 Measurement and data processing
Introduction to Spectrophotometry
Chem. 133 – 3/9 Lecture.
Lab1 A VISIBLE ABSORPTION SPECTROMETER
Chem. 133 – 3/14 Lecture.
Labware.
Spectroscopy Techniques
Estimation of analyte concentration on the basis of light absorption
Fundamental Techniques and Measurements
Beer’s Law P0 Uses of Beer’s Law
Colorimetric Determination of Iron
READING MEASUREMENT SCALE INSTRUMENTS
Measurement of Volume Chapter 20.
Preparing Standard Solutions
Chapter 3 - Measurements
DENSITY.
Utilizing Spectrophotometry in Life Science
Lecture 2b Beer’s Lambert Law.
Titration Ensuring good volumetric technique
Diluting Aqueous Solutions (page )
Molarity Chem 11 : Molarity
Chapter 3 - Measurements
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Can observe color using absorption spectroscopy (which looks at the intensity of light absorbed versus intensity of light transmitted)
SPECTROPHOTOMETRY Applied Chemistry.
Common Laboratory Glassware
Sample AP Model Drawing Question
Solution Preparation Experiment
Laboratory Glassware.
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
Pharmaceutical Measurement
Identification of the common laboratory glassware, pipettes and instruments . BCH 312 [PRACTICAL]
Clinical instrumental analysis
Presentation transcript:

Fundamental Techniques and Measurements Mass Measurements Volume Measurements Preparation of a solution of known concentration UV-Visible Spectrophotometer

Electronic Balance What does an electronic balance measure? _____ If you took an electronic balance with a capacity of 100 g to the moon what would its range be? _____ force 600 g Why do good electronic balances have bubble level indicators?

Mass: Electronic Balance Accuracy 4 to 6 significant digits Calibration Use known mass Check weekly or when balance is moved Sources of error Balance must be calibrated and maintained in same orientation in _________ field hydroscopic chemicals: dry to constant mass first (will increase in mass rapidly as they reabsorb water on the balance!) When preparing a solution of a given concentration it may be difficult to get the exact mass desired____________ evaporation of wet samples gravity report actual!

Electronic Balance M o d e l C a p a c i t y R e s o l u t i o n D I - 1 1 g . 1 g D I - 8 8 g . 1 g D I - 5 5 g . 1 g For maximum accuracy use balance with _______ resolution possible! Don’t forget to clean the balance if you spill any chemicals!!!!!! smallest

Volume Volumetric flask Graduated cylinder Beaker Pipette accuracy of ______/100 mL Graduated cylinder Beaker accuracy of _____/100 mL Pipette accuracy of ± _____ for 100-1000 µL accuracy of ± _____ for 10-100 µl What will accuracy of solution be if you use pipette, volumetric flask, and electronic balance? ________ 0.16 mL 1 mL 1 % What controls the accuracy? _______ 5 mL Pipette 0.6% 0.8%

Digital Pipettes Air displacement Do not directly contact fluid volume avoids contamination of pipette avoids sample carryover Require air tight connection between tip and body

Pipette Workings piston cylinder Pipette tip

Preparation of Solutions Example: Prepare 100 mL of a 30 mM solution of methylene blue. The molecular weight of methylene blue (C16H18N3SCl) is 319.87 g. 𝐶𝑉=𝑀 = concentration conversion volume mass

Preparation of Dilutions Prepare 100 mL of a 300 µM solution from the 30 mM solution Conservation of _____ mass 𝑉 𝑐𝑜𝑛𝑐𝑒𝑛𝑡𝑟𝑎𝑡𝑒 = = 1 mL

Preparation of Solutions Fill volumetric flask half way with distilled water Add reagent (could be solid or liquid) Mix Fill volumetric flask to the line Verify that volume didn’t change (if necessary refill to line)

UV-Visible Spectrophotometer Theory Instrument Sample requirements Software

Light Attenuation by an Aqueous Solution P0 P P0 P P is light intensity (photons/s)

Theory: Light Attenuation = f(?) For a given excitation process, a molecule absorbs only one discrete amount of energy: expect very narrow absorption lines. Different vibrational and rotational states yield _______ absorption lines. First order decay with distance broad

A=bc Po - _________ light intensity P light intensity after passing through sample b - ______________ c - ______________  - ___________ coefficient (function of wavelength and molecule) incident path length (1 cm) concentration extinction e is not a function of concentration!

Absorption Spectra orange blue Absorption Spectra for Methylene Blue Broad peaks Absorbs ________, looks ______ orange blue

Instrument Light Path

Sample Requirements detector Light source Sipper cell sample pump peristaltic pump draws sample into sipper cell requires a few mL to displace previous cell contents sample pump detector Light source

Software calibration Reference (single sample) measures absorbance of sample cell and reference solution usually distilled water or reagent blank Standards (multiple samples) used to create a __________ curve Samples (multiple samples) after sampling, standards can be used to estimate the concentration of samples calibration

Absorbance Measurement Limitations Po is a function of the _____. If absorbance is high what is P? ______ Suppose A = 3, what is Po/P? _____ Suppose I create samples of higher and higher concentration. What will happen to the absorbance measurements? lamp small 1000 There is a _________ (non zero) P that can be measured by an instrument. minimum A _______ keep increasing! doesn’t Amax 3

Maximum Absorbance: P0 is measured as reference! Max absorbance f() ________________ absorbance readings that exceed this value will not be used in analysis lamp intensity detector sensitivity cell absorbance reference absorbance acceptable error

Standards Include zero your name general description rinse time sample time sample concentrations Include zero select number of samples by moving this control

Samples enter sample descriptions here select number of samples by moving this control