Rapid method for direct identification of bacteria in urine and blood culture samples by matrix-assisted laser desorption ionization time-of-flight mass.

Slides:



Advertisements
Similar presentations
Models for the organisation of hospital infection control and prevention programmes B. Gordts Clinical Microbiology and Infection Volume 11, Pages
Advertisements

S. Emonet, H.N. Shah, A. Cherkaoui, J. Schrenzel 
C.-S. Lee, J.-H. Lee  Clinical Microbiology and Infection 
B. Schulz, K. Weber, C. Radecke, C. Scheer, M. Ruhnke 
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry for the rapid identification of yeasts causing bloodstream infections  A.K.
Matrix-assisted laser-desorption/ionization BIOTYPER: experience in the routine of a University hospital  E. Bessède, M. Angla-gre, Y. Delagarde, S. Sep.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identification  A. Bizzini, G. Greub 
Gut bacterial microbiota and obesity
C.-S. Lee, J.-H. Lee  Clinical Microbiology and Infection 
Gastroenteritis outbreak caused by norovirus associated with the children's club of a hotel located in Majorca, Spain  A. Doménech-Sánchez  Clinical Microbiology.
Matrix‐assisted laser desorption ionization time‐of‐flight mass spectrometry for fast and accurate identification of clinically relevant Aspergillus species 
R. Cantón  Clinical Microbiology and Infection 
Detection of microorganisms in blood specimens using matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a review  M. Drancourt 
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry: revolutionizing clinical laboratory diagnosis of mould infections  M. Gautier,
Y.R. Fu, Z.J. Yi, S.Z. Guan, S.Y. Zhang, M. Li 
Use of mass spectrometry to identify clinical Fusarium isolates
S. Emonet, H.N. Shah, A. Cherkaoui, J. Schrenzel 
Rapid detection of enterobacteriaceae producing extended spectrum beta-lactamases directly from positive blood cultures by matrix-assisted laser desorption.
Diagnosis of Aerococcus urinae infections: Importance of matrix-assisted laser desorption ionization time-of-flight mass spectrometry and broad-range.
Vector control: a cornerstone in the malaria elimination campaign
Do we need new antibiotics?
Polymerase-chain reaction/electrospray ionization-mass spectrometry for the detection of bacteria and fungi in bronchoalveolar lavage fluids: a prospective.
F. Bittar, J.-M. Rolain  Clinical Microbiology and Infection 
The occurrence of Legionella species other than Legionella pneumophila in clinical and environmental samples in Denmark identified by mip gene sequencing.
Comparison of clinical and environmental isolates of Legionella pneumophila obtained in the UK over 19 years  T.G. Harrison, N. Doshi, N.K. Fry, C.A.
Levofloxacin in the treatment of ventilator-associated pneumonia
R. Bitterman, M. Paul, D. Polak, Y. Geffen 
Automated categorization of methicillin-resistant Staphylococcus aureus clinical isolates into different clonal complexes by MALDI-TOF mass spectrometry 
A simple, robust and rapid approach to detect carbapenemases in Gram-negative isolates by MALDI-TOF mass spectrometry: validation with triple quadripole.
Metagenomics and probiotics
Detection of carbapenemases in Enterobacteriaceae: a challenge for diagnostic microbiological laboratories  J. Hrabák, E. Chudáčkova, C.C. Papagiannitsis 
Evaluation of matrix-assisted laser desorption ionization-time-of-flight mass spectrometry in comparison to rpoB gene sequencing for species identification.
Brucella detection in blood: comparison of the BacT/Alert standard aerobic bottle, BacT/Alert FAN aerobic bottle and BacT/Alert enhanced FAN aerobic bottle.
Impact of rapid microbial identification directly from positive blood cultures using matrix- assisted laser desorption/ionization time-of-flight mass spectrometry.
Establishment of a matrix-assisted laser desorption ionization time-of-flight mass spectrometry database for rapid identification of infectious achlorophyllous.
Blood culture-based diagnosis of bacteraemia: state of the art
T.M. File  Clinical Microbiology and Infection 
A. S. Hadziyannis, I. Stephanou, K. Dimarogona, A. Pantazatou, D
Evaluation of matrix-assisted laser desorption ionization-time of flight mass spectrometry for species identification of Acinetobacter strains isolated.
Advantages and limitations of genomics in prokaryotic taxonomy
Antibacterial drug discovery in the 21st century
Abstracts cont. Clinical Microbiology and Infection
Effect of metronidazole versus standard care on length of stay of patients admitted with severe infectious mononucleosis: a randomized controlled trial 
A novel fluorescence in situ hybridization test for rapid pathogen identification in positive blood cultures  A. Makristathis, S. Riss, A.M. Hirschl 
Real-time PCR assays compared to culture-based approaches for identification of aerobic bacteria in chronic wounds  J.H. Melendez, Y.M. Frankel, A.T.
Tuberculosis transmission patterns among Spanish-born and foreign-born populations in the city of Barcelona  S. Borrell, G. Tudó, E. Rey, J. González-Martín 
Comparison of different methods for identification of species of the genus Raoultella: report of 11 cases of Raoultella causing bacteraemia and literature.
A.P. Underwood, J. Green  Clinical Microbiology and Infection 
Circulation of international clones of levofloxacin non-susceptible Streptococcus pneumoniae in Taiwan  Y.-C. Hsieh, L.-Y. Chang, Y.-C. Huang, H.-C. Lin,
H. Leblebicioglu, C. Eroglu  Clinical Microbiology and Infection 
Sequential time to positivity of blood cultures can be a predictor of prognosis of patients with persistent Staphylococcus aureus bacteraemia  M.-S. Hsu,
Correlation between time to positivity of blood cultures with clinical presentation and outcomes in patients with Klebsiella pneumoniae bacteraemia: prospective.
An after-hours clinical liaison blood culture service—is it worth it?
Statin use and clinical outcomes among pneumonia patients
Clinical Microbiology and Infection
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry and PCR- based rapid diagnosis of Staphylococcus aureus bacteraemia  O. Clerc,
Matrix-assisted laser desorption ionization-time of flight mass spectrometry for fast and accurate identification of Pseudallescheria/ Scedosporium species 
The atypical pneumonias: clinical diagnosis and importance
J.J. Keller, M.-C. Tsai, C.-C. Lin, Y.-C. Lin, H.-C. Lin 
Modelling during an emergency: the 2009 H1N1 influenza pandemic
R. Khatib, G. Simeunovic, M. Sharma, M. G. Fakih, L. B. Johnson, L
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry identifies 90% of bacteria directly from blood culture vials  W. Moussaoui,
J.L. Balcázar  Clinical Microbiology and Infection 
G.C. Schito  Clinical Microbiology and Infection 
Identification of Leishmania at the species level with matrix-assisted laser desorption ionization time-of-flight mass spectrometry  C. Cassagne, F. Pratlong,
Impact of antibiotic restrictions: the patient's perspective
Comparative study of pediculicidal effect of medical plants
CMI readers' survey Clinical Microbiology and Infection
The future of diagnostic bacteriology
Rapid detection of antibiotic resistance by MALDI-TOF mass spectrometry using a novel direct-on-target microdroplet growth assay  E.A. Idelevich, K. Sparbier,
Presentation transcript:

Rapid method for direct identification of bacteria in urine and blood culture samples by matrix-assisted laser desorption ionization time-of-flight mass spectrometry: intact cell vs. extraction method  L. Ferreira, F. Sánchez-Juanes, J.L. Muñoz-Bellido, J.M. González-Buitrago  Clinical Microbiology and Infection  Volume 17, Issue 7, Pages 1007-1012 (July 2011) DOI: 10.1111/j.1469-0691.2010.03339.x Copyright © 2011 European Society of Clinical Infectious Diseases Terms and Conditions

FIG. 1. Diagram of the general workflow in the analysis of urine and blood culture samples by matrix-assisted laser desorption ionization (MALDI) time-of-flight mass spectrometry. Clinical Microbiology and Infection 2011 17, 1007-1012DOI: (10.1111/j.1469-0691.2010.03339.x) Copyright © 2011 European Society of Clinical Infectious Diseases Terms and Conditions

FIG. 2. Comparison of the intact cell method and the extraction method in urine and blood culture samples analysed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. The samples compared are those with coincidence at the genus level with plate culture and biochemical identification. Clinical Microbiology and Infection 2011 17, 1007-1012DOI: (10.1111/j.1469-0691.2010.03339.x) Copyright © 2011 European Society of Clinical Infectious Diseases Terms and Conditions

FIG. 3. Mass spectra (size 2.000–11.000 Da) of Proteus mirabilis and Klebsiella pneumoniae from urine samples obtained with the intact cell method (a) and with the protein extraction method (b). a.u., arbitrary units. Clinical Microbiology and Infection 2011 17, 1007-1012DOI: (10.1111/j.1469-0691.2010.03339.x) Copyright © 2011 European Society of Clinical Infectious Diseases Terms and Conditions