Red – ASTM 5 Black - ASTM 6 Blue - ASTM 7 * Not 900°C

Slides:



Advertisements
Similar presentations
Cavity package T.Saeki BCD meeting 20 Dec Cavity shape BCD: TESLA shape Pros: small wakefield, HOM thoroughly investigated single-cell: 43 MV/m.
Advertisements

Rong-Li Geng Jefferson Lab High Efficiency High Gradient Cavities - Toward Cutting Down ILC Dynamic Heat Load by Factor of Four R.L. Geng, ALCW2015,
Cavity status; recent KEK activities : Hayano (1) STF CM-1 cavities are; MHI-014: 3-rd VT:36MV/m (finished) MHI-015: 3-rd VT: > 18.4MV/m.
Nb 3 Sn Cavity ERL1-4 History of ERL1-4 – Nb 3 Sn coating, just HPR Test shows relatively flat Q vs E up to quench at ~13 MV/m, Q~1e10 – 5x HF rinse, HPR.
Achievement of 41 MV/m Gradient by AES8 Rong-Li Geng Jefferson Lab ALCPG09, October 1, 2009.
R.L. Geng, 5/27-31,2013 ECFA LC2013, DESY 1 Update on Raising Q0 at Ultra-High Gradient via Large-Grain Niobium Material Rongli Geng Jefferson Lab ECFA.
Rongli Geng March 4, th LCC ILC Cavity Group Meeting
Alors, c’est fini! Et maintenant?. Machine Upgrade in Stages Push LHC performance without new hardware –luminosity →2.3x10 34 cm -2 s -1, E b =7→7.54.
Sindhunil Barman Roy1 and Ganapati Myneni2
40 Minutes Left.
CEPC 1.3GHz & 650MHz SC cavity high Q R&D Z.C. LIU #, P. Sha, H.J. Zheng, J.Y. Zhai, M.Y. Wang, G.W. Wang, Y. Sun, J. Gao
JLab Update Rongli Geng April 30, th LCC ILC Cavity Group Meeting.
Summary of Results and Development of Online Monitor for T-mapping/X-ray-mapping in KEK-STF Y. Yamamoto, H. Hayano, E. Kako, S. Noguchi, M. Satoh, T. Shishido,
High Temperature Heat Treatment to Raise the Quality Factor of Large Grain Niobium Cavities Pashupati Dhakal Gianluigi Ciovati Ganapati Rao Myneni July.
SRF Cost Reduction for Project X Bob Kephart. SRF Challenges for Project X Adoption of a 3 GeV CW linac followed by a 3-8 GeV pulsed linac for Project.
Annual Meeting CERN - November 2005 Bernard V ISENTIN.
New Ideas & Approaches to Raise CEBAF Q 0 - Initial Results and Proposed Studies Rongli Geng, Gigi Ciovati July 15, OPS StayTreat.
Next Generation Nb 3 Sn cavities: Current performance, limitations, and considerations for practical use Daniel Hall Matthias Liepe.
July 5th,2006John Mammosser, Jlab ILC – Electropolish Development (EP) Plans/Progress/Problems/Performance Jefferson Lab J. Mammosser, L. Phillips, C.
SRF Operating Experience at JLab
Rongli Geng ILC Cavity Group Meeting October 25, 2011
LCLS-II Technical Requirements
Juliette Plouin, Enrico Cenni, Olivier Napoly (CEA)
LCLS-II Cavity Production and Vertical Testing
Update on the US decadal roadmap on SRF technology for HEP accelerators Sergey Belomestnykh FCC Week 2017 in Berlin 30 May 2017.
Cavity Test Results for PIP-II
CEPC Nitrogen Doping Study
Ari D. Palczewski, SRF Scientist
New Cavity Techniques and Future Prospects
JLab infusion and LG flux expulsion update
State of the Art and Future Potential of Nb/Cu Coatings
for the FNAL/ANL, JLab, and Cornell cavity teams
Peng Sha Institute of High Energy Physics, CAS
CEPC 1.3GHz and 650MHz high Q Nitrogen doping R&D progress
High Q via N infusion R&D at Jefferson Lab
High Q R&D at Fermilab Anna Grassellino TTC Topical Meeting on CW SCRF
EZ Infrastructure for SC cavities production
R&D Activity for Field Emission and Vertical EP
Jiyuan Zhai ( IHEP ) TTC Meeting, JLAB, 6 Nov 2012
9-cell Vender Qualification test for LCLS-II
Recent SCRF Activities in IHEP
Working Group 3 Summary TTC Meeting INFN Milan,March 3, 2011
TTC High Q0 Working Group Summary of developments since last TTC meeting C. Reece.
High Q Cavity Operation in the Cornell Horizontal Test Cryomodule
LCLS-II CM Ambient Magnetic Field Management
Highlights from EU Global Design Effort
Mechanical Polishing of 1.3 GHz Niobium Cavities
LCLS-II 9 cell production update and change of recipe update
TTC WG-2 focusing on Nb Material - Properties and Specifications -
Future Thin Film Deposition Efforts at FNAL
Status of CEPC SC RF Study
Matthias Liepe Zachary Conway CLASSE, Cornell University June 1, 2009
LCLS-II High Q0 Cavities: Lessons Learned
Cavity Treatment for High Q0 in Realistic Magnetic Fields
Performance Recovery at CEBAF
Vertical Test Results of 9-Cell Cavities for LCLS-II
Surface resistance studies as a function of the mean free path
FNAL update Martina Martinello.
LCLS-II HE R&D ongoing results
Peng SHA, On behalf of CEPC SRF group
Nb films Sergio Calatroni for the new CERN SRF & films team 5/21/2019
JLab Doping Protocol Exploration
8-T Solenoid Package and Local Magnetic Shielding in FRIB Cryomodules
Quench Studies in Single and Multicell N-Doped Cavities
Field Emission and Mitigation in the CEBAF Linacs R Legg, R Geng Jlab SRF Ops Dept. TTC,
Magnetic Field Sensors and Measurements in Cryomodules
Low-T Baking at Cornell
JLab Work on Low Temperature Near-Surface Diffusion aka “Infusion”
The LCLS-II HE High Q0 and Gradient R&D Program
Cool Down Studies of LCLS-II Cryomodules
Presentation transcript:

Flux expulsion of new material – Tokyo Denkai niobium cavities all @ 900°C 3 hours Red – ASTM 5 Black - ASTM 6 Blue - ASTM 7 * Not 900°C One ASTM 7 ingot lot temperature raised to 950°C all other lots kept at 900°C – lot 92 ASTM 7 ingot Lot 99 left alone with knowledge it will just meet the specification – all other lots expected to exceed specification LCLS-II specification comes from the cooldown and magnetic field specification for the cryomodules

HE R&D – new recipe After the initial 2n6 recipe was developed for the baseline LCLS- II recipe we continued exploring the doping using short doping runs of 1-3 minutes, plus annealing cycle of 40 to 60 minutes. – lower doping There were some interesting initial results which were not explored because of LCLS-II production needs – 2014 data 2N60 – EP5

First results of new recipe - preliminary 2K world record @ 1.3GHz* Recipe could be used to upgrade C100’s at JLab 2 of the 3 first cavities pass our goal and exceeded the HE specifications. @ 5 & 10 micron removal Re-doping and verification underway* SC-07 appears to be defect limited by manufacturing flaw – retests underway SC-07 trapped ~ 2-4mG of field during this test, others expel well

Re-dope SC-04 – quench @ 23-25MV/m (previous 30-35MV/m)

Re-dope trapped flux ratio SC-04