Welcome.

Slides:



Advertisements
Similar presentations
Pneumatic Valves Lesson 4.
Advertisements

Contents: Cover
YUSUF OZ FATIH BOLUKBAS HUSEYIN ANIL KARABULUT. INTRODUCTION HOW DOES A CONTAINER BECOME HOUSE? DESIGN EXAMPLES A NEW HOME IN 12 STEPS TECHNICAL SPECIFICATIONS.
Architectural Services Department HKSAR Laboratory Design for Secondary Schools.
Suspension Systems - 1 Topics covered in this presentation:
Containment Equipment and Facilities. Biocontainment The principle of holding or being capable of holding or including within a fixed limit or area The.
Chemical Fume hood or Biosafety Cabinet
FUME CUPBOARDS ASHRAE CERTIFIED TOTAL LABORATORY SOLUTIONS.
Series L Air conditioners for Laboratories.
USER MAINTENANCE.
PGS Introduction "Value Series" : Best VALUE gaming cases with the highest C/P Ratio (Cost to Performance ratio). "Professional Series – Red label" :
Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan assisted NIKE Star 23 kW EOLO Star 23 kW.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Customer Service – International Dept. The thermal solar systems  Installation  Commissioning  Maintenance.
Airflow and BSC Biosafety and Biosecurity Awareness Training
FLOW measurements.
Refrigerators.
Unit 206: Domestic hot water systems
AIR CONDITIONING ACCESSORIES
Purpose Body Making module is designed for bending the laminated foil film in the shape of a tube, for welding the side seam and for cutting bodies with.
Pneumatics Pneumatik By Clifford Mayhew St Helens College
Module 6 : Flow control valves
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Engineering Controls and Laboratory Design Session 4 Laboratory Safety Training.
SMAW (Stick Welding) SECTION OVERVIEW:
Siemens Building Technologies, Inc. ED&G 100 Design Project Fume Hood Face Velocity Control Spring 2004.
Prepared by Farid Khalaf.  Protect the worker.  Protect the sample being analyzed.  Protect the environment.
WELCOME.
Chemical Fume Hood  A type of local ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts.
19 May 2015 AirGuard Protection System Protection units for compressed air.
QUINCY ROTARY SCREW AIR COMPRESSOR QGL 15-37kW
Actuators.
Engineer Training Mechanical Overview. Engineer Training Confidential 2 XL1500 is both Roll-to-Roll and Roll-to-Sheet Printer MachineXL1500-2mXL1500-3mXL1500-5m.
Health and Safety Training Standards in Design and Technology
(Trouser Finishing Machinery) Presented By: Shailesh Prajapati Sneha B. Hulkoti R.O.I. CALCULATION FOR DIFFRENT LEVEL OF TECHNOLOGY Department of Fashion.
ISH Innovation 2015 Pre-wall/flushing technology
WALDNER Laboreinrichtungen GmbH & Co. KG Wangen im Allgäu WALDNER Presentations The mc6 ® Furniture System Laboratory Examples  Analytical Laboratory.
World Health Organization
THE HYDROFLOW STAR FILTER
Update on alignment kit and stave 250 frame M.Gibson (RAL) 1.
Air Conditioning International Mechanical Code
Percussion drilling By Batch -2. Percussion drilling Cable Tool Drilling Percussion drills have been used to drill thousands of feet, though they are.
A PRESENTATION on “ SUSPENSION SYSTEM ”
Vacuum system.
MKT May 2012 C850: Fast sliding gate operator. MKT May 2012 Summary  Why a fast slider operator?  USPs  Applications  Details  Technical specifications.
“PCA” – Polyclean Applicator the patented application system
Aaron’s Engine Anatomy
Lindab | we simplify construction - Flexibility when it is needed... Premum & Premax With unique JetCone and Angled Nozzles Patent pending solution.
Lab design Assignment 3 Unit 2.
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
Engine Brake VEB + VEB + is the name of the Volvo engine braking system and is a further development of the VEB engine brake. Engine brake VEB + consists.
1  2008 Kaeser Compressors, Inc., USA (V2.2) “Specifications are subject to change without notice” Presenting... Kaeser Omega Blowers.
We are one of the accredited manufacturers and suppliers of Accoustic Enclosure and Sound Proofing in northern part of India under brand Name of "DDSTHA".
Integrated Blower Packages Kaeser Integrated Blower Family.
The GranView Fireplace
INDUSTRIAL PNEUMATICS
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
(Modified from University Of South Carolina)
BUILDING HEATING AND COOLING
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
Smokes extraction principle
Laboratory Ventilation
Suspension Systems - 1 Topics covered in this presentation:
Risk Management Student Powerpoint
Presentation transcript:

Welcome

Definition: Fume Cupboard - Regulations - Standards DIN 12 924 part 1 defines the fume cupboard as a protection device in laboratories for works during which gases, vapours, aerosols or dusts can occur in hazardous quantities and concentrations. The Euro Fume Cupboard fulfills the requirements of all appropriate standards and regulations: DIN British Standard AFNOR (French Standard) ASHRAE (US-Standard) EN (European Standard soon to come)

GS - Label This Euro Fume Cupboard is tested and certified according to the law for safety of appliances. Just as the complete laboratory furniture system, also this fume cupboard is equipped with the GS label.

Types and Dimensions Types bench fume cupboard low level fume cupboard walk-in fume cupboard low ceiling height fume cupboard special application fume cupboard (DIN 12 924 part 2) filter fume cupboard radio-isotope fume cupboard (DIN 25 466) Dimensions All Euro Fume Cupboard types are available in widths of 1200, 1500 and 1800 mm.

Construction – Installation The Euro Fume Cupboard consists of the independent main parts: fume cupboard underbench and fume cupboard top. Both units are completely factory- assembled and are delivered to the site ready for connection.

Construction – Installation Should the conditions on site not enable a pre-assembled delivery, the Euro Fume Cupboard will be put up on site from pre-assembled components.

Construction – Characteristics The fume cupboard underbench comprises: two side panels of coated chipboard two epoxy resin coated upright in the rear; each with levelling device. two epoxy resin coated aluminium profiles at the front with integrated height adjustment two epoxy resin coated steel traverses to hold the worktop

Construction – Characteristics The fume cupboard top comprises: two side panels of coated chipboard one rear panel of coated chipboard one front panel of epoxy resin coated sheet steel one firmly installed sash with epoxy resin coated aluminium frame and hardened laminated safety glass one front sash or two synchronously running front sashes with epoxy resin coated aluminium frame and hardened laminated safety glass

Construction – Characteristics The fume cupboard top comprises: one worktop (of synthetic ceramics, PP, epoxy resin or according to requirement) two or three detach-able service panels integrated in the back panel one rear baffle of solid grade laminate one top baffle of solid grade laminate one front and rear ceiling of coated chipboard one integrated light one exhaust air manifold of PP, hardly flamable

Construction – Front Sash 1 sanitary service panel 2 rear baffle 3 air intake openings 4 electrical service panel 5 scaffold rod holders 6 scaffold rods 7 cup sink The Euro Fume Cupboard is equipped with a vertically adjustable front sash and with a sash of laminated safety glass, which is firmly installed on top.

Construction – Front Sash 1 front toothed disk 2 tooth belt 3 front sash 4 rear panel of fume cupboard 5 counter-weight 6 plywood panel (4 mm) 7 rear toothed disk Through two toothed belts, which are independently running via a front and a rear toothed disk, the front sash is connected to two counter-weights. The counter-weights are running without any restricted guidance.

Construction – Front Sash 31 1 intact tooth belt 2 clamping plate (pulled-up) 3 track mechanism (not released) 4 torn tooth belt 5 clamping plate (pressed down) 6 track mechanism (released) 7 spring The front sash is equipped with an aluminium frame on both sides and with an additional anti-skid device. If the toothed belts are properly working, a track mechanism against spring pressure is lifted. In case the toothed belt is torn, the spring will press the track mechanism to the outside and is wedged in the routing profile. Thus it is reliably avoided that the front sash will fall down in case of an error. 1 4 2 5 3 6 7

Construction – Splinter Protection Illustration: sash in opened position The sash handle at the lower side of the front sash is formed in such a way that splashes, splinters or similar are re-routed down to the worktop if the sash is closed. 1 front sash 2 sash handle 3 double handle profile 4 air-foil cill

Construction – Service Panels – Scaffold Rod Holders In the interior of the fume cupboard top up to three service panels are integrated in the rear panel. These service panels are either equipped with various supplies for water, gas, vacuum, compressed air, etc. or with a drip cup, or sockets for electricity. The valves and switches are located in the service modules of the fume cupboard underbench. The fume cupboard rear panel is equipped with up to 12 scaffold rod holders ( polybutylen-terephtalate) with cam fixing for scaffold rods with a diameter of 13 mm. Service Panels

Construction – Service Modules Each service module (300 mm wide, 180 mm high) can be individually equipped. The sanitary module can be equipped with several valves which are colour-coded and allocated to the outlets in the service panel at the rear panel of the fume cupboard. The electrical module can be equipped with rotary switches, press switches, sockets and fuse protections. These switches are also allocated to the sockets in the service panel at the rear panel of the fume cupboard. Service Modules

Construction – Ventilation Connection The exhaust air manifold is installed above the rear ceiling and is equipped with a connection diameter of 250 mm in order to allow an easy connection to a ventilation system. The exhaust air manifold is also equipped with two air intake openings with a diameter of 200 mm each.

Construction – Aerodynamics – Sash Handle and Worktop Front air foil cill The air foil cill at the front of the worktop is aero- dynamical in shape. . Sash handle The aerodynamic shape with clear tear-off edges provide for defined flow proportions at the sash handle. The backflow of the double profile causes a clear under pressure reduction when opening the front sash. Thus considerably better results are achieved during the dynamic contaminant test according to DIN 12 924. Illustr.: flow test in flat water duct Illustr.: flow visualization in mist test

Aerodynamics – Profile Support The aerodynamic shape of the patent-applied profile of the Euro Fume Cupboard reduces turbulences. Thus backflows are avoided and the results of the containment tests according to DIN 12 924 are improved considerably. The laboratory staff is better protected. Illustr.: flow test in flat water duct

Aerodynamics – Distribution of Extraction Criterions for an optimized distribution of extraction at the rear panel are: An even extraction through the entire fume cupboard interior (reduction of air circulation in favour of a piston flow). Extraction of heavy gases (e.g. vapours of solvents, bromine) by pulling down the baffle tightly above the worktop. Low pressure loss at high air volumes (EN, BS, ASHRAE). Service panels with circulating extraction slots completely integrated in the rear baffle.

Control and Regulation The Euro Fume Cupboard is equipped with the fume cupboard function display (FAZ) as required in DIN 12 924 part 1 as a standard. As an option it can be equipped with a variable fume cupboard control, the Airflow-Controller 2, or with a constant airflow controller, the AC-C. Illustr.: operation of the airflow controller Illustr.: operation of the function display Illustr.: damper for airflow controller

Airflow Controller – Damper Furniture System Airflow Controller – Damper Depending on the ventilation concept and the conditions on site the damper of the airflow controller can be executed in various types: manifold damper twin pipe damper pipe damper crossbox A combination with sound absorber is also possible.

Airflow Controller – Control Valves MManifold Damper (The controller is directly installed on the fume cupboard top.

Airflow Controller – Damper DTwin Pipe Damper RThis damper is used instead of the manifold. dThis controller is also available with sound absorber.

Pipe Damper Airflow Controller – Damper JDepending on the pressure loss and on the construction height various dampers can be used. The pipe dampers are installed in the ventilation plant on site.

Ventilation Values Detailed values of the airflows and pressure losses are available for all fume cupboard types. Example: twin pipe controller

Ventilation Values Detailed values of the airflows and pressure losses are available for all fume cupboard types.

Sound Level Extensive measurements were carried out by the Fraunhofer Institute for Building Physics to determine the A-valued sound level for the various Euro Fume Cupboard types and for the various Airflow Controllers.

Euro Fume Cupboard Sash Controller Illustr.: driving motor for SC 2 Each Euro Fume Cupboard can be optionally equipped (also in addition) with the sash controller SC2. It is the task of the SC2 to automatically close the SC2 if nobody is working with the fume cupboard. With a movement detector the SC2 controls the area in front of the fume cupboard for moving persons. As an additional option a photo-electric light barrier can be inserted in the lower cross profile. With this photo-electric light barrier also isothermic and stationary objects (e.g. appliances in the sash area) can be detected. The time between the last detection and the closing process can be adjusted. Illustr.: driving motor for SC 2 Illustr.: movement detector

Commissioning The Euro Fume Cupboard control units FAZ, AC2 and SC2 are completely pre-installed, adjusted and calibrated in the factory. Furthermore they are also subject to an extensive function test.

Integration of Appliances Apart from the control units FAZ, AC2, AC-C and SC2 also decentral service supply units can be integrated. Complete systems for vacuum, cooling water, clean and pure water and for the treatment of waste water are available. Illustr.: distribution and waste disposal system for chemical substances - Chem-Change

Integration of Appliances Through a funnel in the worktop flamable solvents are lead into the FWF 90 safety cabinet.

Thank you very much for your attention