GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial.

Slides:



Advertisements
Similar presentations
Wall Mounted J series Troubleshooting.
Advertisements

Presents: Corrosion Coupon Rack Sales Training General Treatment Products, Inc. Corrosion Coupon Racks December 2013.
1 Tight Fittings…Use Stainless Hose There is seldom enough space. Four connections required: Solar fluid to (top of pump) and from (top of tank) collectors;
Preferred Utilities Manufacturing Corp.
Training Presentation
USER MAINTENANCE.
BeginningNext SlideBack End Program AVADAL 1 of 18 SK-16 Main Pumps 4 Pumps Per Strand – Normally 2 running and 2 on standby as back-up. Motor is 60 HP.
BeginningNext SlideBack End Program AVADAL 1 of 21 SK-1 Roller Apron Segment Overview.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Inner diameter or nominal size Schedule (wall thickness) Basic design criteria –Phase –Flow Pressure –Temperature Example: 2” Schedule 80.
General System Maintenance BUS 4 COMPONENT FLOW.PPT
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
“GTP” General Treatment Products Corrosion Coupon Racks Introduction, Sizes, Models and Trouble Shooting Spring 2006 PCR/CPCR Plastic CSCR/SSCR Metallic.
Air-Conditioning Control Systems
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
“GTP” Bypass & Filter Feeders Introduction, Sizes, Models and Trouble Shooting January 2007 Features & Options Model Numbering  Trouble Shooting  Contact.
Slide: kVA Generating Sets FG Wilson Small Generating Sets kVA Features and Benefits.
Booster System Basics: Constant Speed Systems
Filter manifold Holding tank Iron- manganese filter Aeration tank Control unit Pre- filter To storage tanks Backwash overflow SO2 vent Bypass Cutoff valve.
Sunday, May 17, 2015 Pressure Booster Service. Sunday, May 17, 2015 Booster Service Basics Control Panel Components Setting a pressure switch Setting.
Glycol Pumps Operating Pressure: 100 to 1500 psi Circulation Rate: 3 to 450 gph.
Proper Pump Installation Practices
“GTP Chem-Mix” High Speed Mixers Introduction, Sizes, Models and Trouble Shooting January 2007 Sizing “Chem-Mix” Mixers  Trouble Shooting  Contact Us.
HCS Series Screw Compressor Packages. 2 HCS Series.
CARBURETED FUEL SYSTEM
Hydronic Mechanical Controls
Mechanical for Oil Heat
Glycol Pumps Operating Pressure: 100 to 2000 psi Circulation Rate: 3 to 450 gph.
1 Fuel Pumps. 2 Pumps 1.All oil burners for residential heating have pumps A. They are connected to a motor through a coupling 2.Description A. An oil.
MOST RELIABLE COMBINATION MASTER VALVE, WATER METER AND FLOW SENSOR
09/22/97 Product Overview. Product Index t Suction, Low Pressure (
Experts in Chem-Feed and Water Treatment beta Metering Pumps 1.
FUEL TANKS, LINES, FILTERS, and PUMPS CBCAUTOMOTIVERKCBCAUTOMOTIVERK.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Ships Service Air System
KP Presentation KP1 and KP2 Features. KP Designations The Godiva KP series of rear or midship mounted PTO driven centrifugal fire pumps offers the ultimate.
Discover the Dosmatic Difference Trouble Shooting your Dosmatic injector for years of service.
SYSTEMS. Pumps Systems Our systems are identified as follows Example: model D-CPS-HT-1000-VFD Dis for Duplex units CPSis for Constant Pressure System.
1  2008 Kaeser Compressors, Inc., USA (V2.2) “Specifications are subject to change without notice” Presenting... Kaeser Omega Blowers.
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
Vertical Pump Motor Manifold Upgrade. VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges,
Integrated Blower Packages Kaeser Integrated Blower Family.
10 12 and 14 TR Advanced Glycol Chiller
© Copyright, HQT-SV Control System
Residential Glycol Feeders
Industrial Glycol Feed Packages
HIGH PERFORMANCE PRESSURE SYSTEMS.
“Chem-Mix” High Speed Mixers
10TR Nominal Glycol Chiller
Bypass/Filter Feeders
Figure 18.1 Typical port fuel-injection system, indicating the location of various components. Notice that the fuel pressure regulator is located on.
Connect-CELL Sales Training 2018 Introduction Overview How They Work
Overview Menus & Settings
Fuel Supply System Service
Trouble Shooting Hydraulic System Failure
Troubleshooting 11/14/2018 Water King Service Seminar.
Sales Training 2017 Introduction Overview How They Work Sales Training
Connect-WIFI Sales Training 2018 Introduction Overview How They Work
Instant Electric Heating Tap - Wall Mount or Surface Mount
Corrosion Coupon Racks
Digital Industrial Glycol Feed Packages
Champion RotorChamp HP
UNDERHOOD FEAD (Front End Accessory Drive)
Champion RotorChamp HP
WEMCO® Hydrogritter® II Complete Grit Removal Package
Presentation transcript:

GTP General Treatment Products Glycol Feed Packages Introduction, Sizes, Models, Wiring and Trouble Shooting Spring 2006 GR-E Residential GP-E Industrial Wiring Trouble Shooting Contact Us Introduction GX Wall Mount

Last Home BackNext GTP Introduction GTP Introduction GTP is your new source for: Glycol Feed Systems Glycol Feed Systems Poly and Steel Tanks Poly and Steel Tanks Tank Stands Tank Stands High Speed Mixers High Speed Mixers and Custom Systems. GTP now offers a complete line of: Glycol Feed Systems ranging from: 7.5 Gallon, 15 Gallon, 30 Gallon, 50 Gallon and 100 Gallon Poly and Steel Tanks and Tank Stands ranging from: 5 to 500 Gallon High Speed Mixers - Bracket, Flanged, Clamp, Thread and Tank Mounts ranging from: 1/50HP to 1HP. And a complete package of accessories/options available for each product. With a combined 27 years of industry experience and for a quality product at a great price, let GTP be your new source of H.V.A.C. treatment equipment. Coming soon: A complete line of Bypass/Filter Feeders

Last Home BackNext GR-E Residential Packages GR-E Residential Packages Features 7.5 & 15 Gallon sizes 7.5 & 15 Gallon sizes Industrial Poly Tank and Hinged Cover Industrial Poly Tank and Hinged Cover 0.5GPH Metering Pump 0.5GPH Metering Pump Pressure Switch, Check Valve, Pressure Relief Valve and Isolation Valve Pressure Switch, Check Valve, Pressure Relief Valve and Isolation Valve Surge Chamber Surge Chamber Customer Defined Settings Customer Defined Settings 2 Year Factory Warranty 2 Year Factory Warranty

Last Home BackNext GR-E Residential Packages GR-E Residential Packages Options Pump Outputs: Pump Outputs: 1.0GPH Metering Pump or 6.4GPH Metering Pump Audible Alarm & Silence Switch Audible Alarm & Silence Switch Dry Contact on Low Level Dry Contact on Low Level High Level Alarm High Level Alarm Mixer and Control Switch Mixer and Control Switch Pressure Ranges Pressure Ranges Wall Mounting Bracket Wall Mounting Bracket

Last Home BackNext GR-E Model Numbers GR-E Model Numbers Model Number: GR07- E1-3/HM-AL GR = Base model Residential glycol feed package, tank, hinged lid, control box, 0.5 GPH metering pump, pressure switch, low level switch and indicator, suction and discharge manifold.

Last Home BackNext GR-E Model Numbers GR-E Model Numbers 07 = Tank size GR = Base model Tank size in gallons. Residential packages can be ordered in 7.5 gallon (07) and 15 gallon (15) tank sizes. Model Number: GR07- E1-3/HM-AL

Last Home BackNext GR-E Model Numbers GR-E Model Numbers GR = Base model 07 = Tank size -E1 = Standard package -E1 is the base package which includes standard pump, control panel and manifolds. Model Number: GR07- E1-3/HM-AL

Last Home BackNext GR-E Model Numbers GR-E Model Numbers GR = Base model 07 = Tank size -E1 = Standard package -3 = Pressure code -3 pressure code sets the pressure switch, pressure relief valve and pressure gauge. -3 = 3-10 cut in, 9-30 cut out, 6-20 PSID. Optionally you can order -1 = cut in, cut out, PSID. -2 = cut in, cut out, PSID. Model Number: GR07- E1-3/HM-AL

Last Home BackNext GR-E Model Numbers GR-E Model Numbers GR = Base model 07 = Tank size E1 = Standard package -3 = Pressure code /HM-AL = Optional features /HM-AL Optional codes. This is where you would order optional features such as HM high temperature manifold and AL audible alarm and silence switch. (See pricing for details and additional options) Model Number: GR07- E1-3/HM-AL

Last Home BackNext GP-E Industrial Packages GP-E Industrial Packages Features 30, 55 & 100 Gallon sizes 30, 55 & 100 Gallon sizes Industrial Poly Tank and 1/3 Hinged Cover Industrial Poly Tank and 1/3 Hinged Cover Carbon Steel Frame Carbon Steel Frame Lockable Control Panel Lockable Control Panel 1/3HP Gear Pump 1/3HP Gear Pump Pressure Switch, Check Valve, Pressure Relief Valve and Isolation Valve Pressure Switch, Check Valve, Pressure Relief Valve and Isolation Valve 2 Year Warranty 2 Year Warranty

Last Home BackNext GP-E Industrial Packages GP-E Industrial Packages Options 1/2HP Bronze Gear Pump 1/2HP Bronze Gear Pump High Temperature Manifold High Temperature Manifold Audible Alarm & Silence Switch Audible Alarm & Silence Switch Dry Contact on Low Level Dry Contact on Low Level High Level Alarm High Level Alarm Mixer and Control Switch Mixer and Control Switch Surge Chamber Surge Chamber

Last Home BackNext GP-E Model Numbers GP-E Model Numbers Model Number: GP55- E4-1/HM-AL GP = Base model Industrial glycol feed package, tank, hinged lid, tank stand, lockable control panel, 1/3HP open motor gear pump, pressure switch, low level switch and indicator, suction and discharge manifold.

Last Home BackNext GP-E Model Numbers GP-E Model Numbers 55 = Tank size Tank size in gallons. Industrial packages can be ordered in 30 gallon (30), 55 gallon (55) and 100 gallon (100) tank sizes. GP = Base model Model Number: GP55- E4-1/HM-AL

Last Home BackNext E4 = Standard package, 1/3HP pump -E4 is the base package which includes standard pump, control panel and manifolds. -H4 is a high temp package with steel tank, cover and manifolds. Adding a D before the package (-DE4) will indicate a dual pumps and dual manifolds. GP = Base model 55 = Tank size GP-E Model Numbers GP-E Model Numbers Model Number: GP55- E4-1/HM-AL

Last Home BackNext -1 = Pressure code -1 pressure code sets the pressure switch, pressure relief valve and pressure gauge. 1 = cut in, cut out, PSID. 2 = cut in, cut out, PSID. 3 = 3-10 cut in, 9-30 cut out, 6-20 PSID. GP = Base model 55 = Tank size -E4 = Standard package, 1/3HP pump GP-E Model Numbers GP-E Model Numbers Model Number: GP55- E4-1/HM-AL

Last Home BackNext /HM-AL = Optional features /HM-AL Optional codes. This is where you would order optional features such as HM high temperature manifold and AL audible alarm and silence switch. (See pricing for details and additional options) GP = Base model 55 = Tank size -E4 = Standard package, 1/3HP pump -1 = Pressure code GP-E Model Numbers GP-E Model Numbers Model Number: GP55- E4-1/HM-AL

Last Home BackNext Features Compact Freight Friendly Design Compact Freight Friendly Design Carbon Steel Frame Carbon Steel Frame Lockable Control Panel Lockable Control Panel 1/3HP Gear Pump 1/3HP Gear Pump Pressure Switch, Check Valve, Pressure Relief Valve and Isolation Valve Pressure Switch, Check Valve, Pressure Relief Valve and Isolation Valve 2 Year Warranty 2 Year Warranty GX Wall Mount Glycol Feed GX Wall Mount Glycol Feed

Last Home BackNext Options 1/2HP Bronze Gear Pump 1/2HP Bronze Gear Pump High Temperature Manifold High Temperature Manifold Audible Alarm & Silence Switch Audible Alarm & Silence Switch Dry Contact on Low Level Dry Contact on Low Level High Level Alarm High Level Alarm Surge Chamber Surge Chamber GX Wall Mount Glycol Feed GX Wall Mount Glycol Feed

Last Home BackNext GX Wall Mount Glycol Feed GX Wall Mount Glycol Feed Model Number: GX- E4-1/HM-AL GX = Base model Wall mount freight friendly glycol feed package, wall mount bracket, lockable control panel, 1/3HP open motor gear pump, pressure switch, low level switch and indicator, suction and discharge manifold.

Last Home BackNext GX Wall Mount Glycol Feed GX Wall Mount Glycol Feed Model Number: GX- E4-1/HM-AL GX = Base model E4 = Standard package, 1/3HP pump -E4 is the base package which includes standard pump, control panel and manifolds.

Last Home BackNext GX Wall Mount Glycol Feed GX Wall Mount Glycol Feed Model Number: GX- E4-1/HM-AL GX = Base model E4 = Standard package, 1/3HP pump -1 = Pressure code -1 pressure code sets the pressure switch, pressure relief valve and pressure gauge. 1 = cut in, cut out, PSID. 2 = cut in, cut out, PSID. 3 = 3-10 cut in, 9-30 cut out, 6-20 PSID.

Last Home BackNext GX Wall Mount Glycol Feed GX Wall Mount Glycol Feed Model Number: GX- E4-1/HM-AL GX = Base model -1 = Pressure code E4 = Standard package, 1/3HP pump /HM-AL = Optional features /HM-AL Optional codes. This is where you would order optional features such as HM high temperature manifold and AL audible alarm and silence switch. (See pricing for details and additional options)

Last Home BackNext Wiring: Standard Wiring: Standard The diagram shown is for all systems based on standard items. Optional Dual Pumps Optional Audible Alarm Optional Dry Contact

Last Home BackNext Wiring: Optional Dual Pumps Wiring: Optional Dual Pumps This diagram is for dual glycol systems. Standard Wiring Optional Audible Alarm Optional Dry Contact

Last Home BackNext Wiring: Optional Audible Alarm Wiring: Optional Audible Alarm This diagram is for dual standard systems with audible alarm. Optional Dual Pumps Standard Wiring Optional Dry Contact

Last Home BackNext Wiring: Optional Dry Contact Wiring: Optional Dry Contact This diagram is for dual standard system with dry contact. Optional Dual Pumps Optional Audible Alarm Standard Wiring

Last Home BackNext Trouble Shooting Trouble Shooting PROBLEM POSSIBLE CAUSE OR ACTION Low flow rate Piping / equipment is dirty or fouled. Discharge is restricted or undersized. Gears on pump are worn or fouled. Pump runs, but no fluid Suction piping is restricted or plugged. Piping suction valve is closed. Pump is rotating in the wrong direction. Pressure is low Line is restricted. Gears are worn or fouled. Pump starts and stops running Gears are worn or fouled. The suction line may be clogged. Suction piping is restricted or plugged. Excessive noise while pump is in operation Pump head and gear may be misaligned. Pump mounting hardware is loose. System pressure is excessive. Pump does not shut off at low level Float switch is faulty, defective or damaged. Low level relay is faulty, defective or damaged. Wiring is incorrect or shorted. System does not relieve pressure properly Pressure relief valve is clogged. Pressure relief valve is set improperly. Pump cycles on and off repetitively Piping leak on discharge side. Pressure settings are adequate for system size or pressure. If you still need help, contact us..

Last Home BackNext Contact Us Contact Us Mailing Address: General Treatment Products P.O. Box 8697 Brea, CA Phone: 714) FAX: 714) Internet: Shipping Address: General Treatment Products 254 Viking Ave. Brea, CA 92821