Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels

Slides:



Advertisements
Similar presentations
SATHUNTER Satellite pointing made easy DVB-S2 DVB-S.
Advertisements

Prescient II Extinguishing Control Panels
Auto–Addressable Systems
INTRUSION ALARM TECHNOLOGY
CL100D series DSP controlled Uninterruptible power supplies.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
ID to 8 Loop Intelligent Fire Alarm Panel
Eagle Trading & Agencies has been established from the ground up for selling, managing and implementing mid to large size projects in the field of fire.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Lokotrack ST352 Presentation
NEW QUANTEC FUNCTIONS AND ENHANCEMENTS Available July 2010.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Total HVAC Control from anywhere Easy control that can save a fortune
Discovery 1-4 Loop Analogue Addressable Control Panels
Reliability Different worlds – same problem …one solution: Redundancy
In this presentation you will:
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
PYRO-X De-Ice control devices Technical presentation 2013.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
HARPER CHALICE GROUP LIMITED “PROTECTOR” PulseSecure ™ Fully monitored double pole High and Low voltage Perimeter security system”
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
PYROCON12 De-Ice controller User Operation Presentation 2013.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Precept Conventional Control Panels
Wireless TL70 70 mm Wireless Modular Tower Light
Graphical Alarm Management System
ONYX Product Overview.
Addressable Fire Alarms
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
RP-2000 Series Deluge & Agent Releasing Panels
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Fire Detection Presentation
An Introduction to the Windows-based PC Programming Tool Version 0.91
System Features Interactive Digital Addressable Fire Detection and Alarm System. Designed for Small and Medium Sized Installations.
FG Wilson Access 4000 Control Panel
GasGard® XL Monitor.
Confidential Battery Operated Photoelectric Detector AX-100TFR (30m) AX-200TFR (60m)
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
Translate the following message:
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
HP900 (ESP Protocol) Analogue Addressable Control Panels
Intelligent Detection Systems l integrity of system confirmed continuously l pre-alarm facility l high flexibility of system configuration l performance.
The Guts. CPU CPU Socket The CPU is generally a 2 inch ceramic square with a silicon chip located inside. The chip usually about the size of a thumbnail.
NFS System Components & Installation.
CB200 Conventional Control Panels
2 December, 2015 New Conventional Fire Control Panel.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Precept Marine Conventional Control Panels
CB200 e Cabinet Extinguishant Control Panels Designed for cabinet extinguishant systems 2 zone extinguishant co-incidence operation Selectable discharge.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
Wireless TL70 Sure Cross ® Wireless TL70 Tower Lights combine the best of Banner’s popular Tower Light family with the reliable, field-proven, Sure Cross.
Trey Herrington Electrical Engineer - Backup Power Supply - Backup Power Supply - PCB Design - PCB Design Samantha Prine Electrical Engineer -Enclosure.
Trey Herrington Electrical Engineer - Backup Power Supply - Backup Power Supply - PCB Design - PCB Design Samantha Prine Electrical Engineer -Enclosure.
FireClass Addressable FC501 Part 2 - Panel Use. FC501 Engineering 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
User Operation Presentation
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
Technician Operation Presentation
Honeywell Fire Systems Group RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks.
Presentation transcript:

Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels From 1 to 8 loops Powerful processing and extensive panel and loop I/O capability Fully compatible with all XP95 devices User-friendly controls and a clear, unambiguous screen Alarm threshold adjustments by device Day/night alarm delay feature Messages edited by PC or keyboard

Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels Multiple, fully functional panel displays Radio pager facility Easy to use, Windows-based PC software package Fully networkable with graphics package, network repeaters & other Nexus panels Designed to meet BS5839 Part 4

Panel Enhancements Up to 31 8-way panel enhancement boards may be added. Two types are available: 1) fully-programmable inputs and relay outputs 2) fully-programmable inputs and alarm outputs Remote Inputs for Silence Alarms, Reset, Evacuate, Class Change, Fault, Buzzer Silence. Fully programmable network comprising other Nexus multi-loop panels, graphics systems and network repeaters. A wide variety of loop devices are supported, including XP95 detectors, call points, loop sounders, outstations and intrinsically safe devices. Individual panels and Nexus panel networks are programmable via Windows PC package. Up to 13 remote panel displays, providing full user & engineer facilities may be connected via RS485 cable.

Fully Flush Cabinet (Illustrated) Cabinet Options Surface Cabinets Cabinet colour reference is: RAL 7035 textured (Light Grey) All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint. Semi-Flush Cabinets The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall. It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet. Fully Flush Cabinet (Illustrated) Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted. This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time-consuming). For details of panel dimensions see Application Guide.

Mechanical Assembly Motherboard holds Konex network card and 2 loop cards. Motherboard and power supply located on removable chassis to assist cabinet installation. Loop extension motherboard - this chassis is located in the right hand section of the enclosure. Display assembly located on removable door. A1535 programmable relay board / A1536 programmable alarm board - a maximum of 2 boards may be housed internally and up to 29 externally. Zone LEDs and option printer are located on display board. Space for internal 12Ah battery set.

System LED indications are provided in addition to the LCD display. User Controls The backlit LCD display gives information of loop, device and zone number, device type and event condition, together with a user-definable text description. The text descriptions give the user clear, single-operation functional controls. The engineer accesses panel configuration functions using the numerical designations. The menu structure on the LCD display guides the engineer through the different set-up facilities. System LED indications are provided in addition to the LCD display.

Typical LCD Illustration The device types which may be indicated are as follows: SOU - Loop sounder/sounder circuit controller O/S - Input/Output device ION - Ionisation smoke sensor MON - Monitor (zone monitor, control monitor) OPT - Optical smoke sensor HEAT - Heat sensor BGU - Call point or call point monitor

Display /Repeater PCB (A1575) Viewed from Inside Cabinet Comms link to the main panel motherboard. Power supply fault input when used as a repeater with a local power supply unit. LCD display. System Eprom. S13 Display number Address switch (Node Address Switch) 16 way ribbon connector to the zone board. 16 way ribbon connector to the printer interface. DC power in.

Zone Indications The Nexus 1-8 loop panel provides 64 fully programmable zone LEDs. The zone identification label may be inserted from inside the cabinet

Engineer Facilities The fault LEDs, fuses and DIL switch are easily accessible for the engineer when the user display board has been removed.

Battery supply fuse - 6.3 Amps. Power Supply The fault LEDs, fuses and DIL switch are easily accessible for the engineer when the user display board has been removed. Decoupling link. 230V AC supply. Test lamp switch. Battery supply fuse - 6.3 Amps. These LED indications give the engineer more details of the fault when the “Power Supply Fault” message has appeared on the panel display.

Printer Hinged access to allow easy ribbon change. This good quality printer uses a reliable Epson mechanism. Engineer’s printer test button. Open access to feed paper through mechanism. This button advances the paper. Designed for easy replacement of the paper roll onto the carrier.

RS485 comms from panel motherboard. A1535 8 Way Relay Board RS485 comms from panel motherboard. Engineer’s DIL switches to set board address, enable O/C or S/C inputs and disable inputs/outputs. 8 inputs may be normally open or normally closed and will register as fire or non-fire on the panel as configured. Inputs are fully programmable via the panel or PC cause/effect. 8 x 1Amp changeover relay outputs may be fully programmed via the panel or PC cause/effect programme. Engineer’s links to disable functions for set-up or maintenance purposes. 24V DC power.

A1536 8 Way Alarm Board Engineer’s DIL switches to set board address, disable inputs and outputs, test LEDs and test alarms. Engineer’s DIL switches to isolate alarm outputs individually. RS485 comms from panel motherboard. 8 x 1Amp two-stage alarm outputs may be fully programmed via the panel or PC cause/effect. 8 normally open inputs which will register as fire or non-fire on the panel as configured. Inputs are fully programmable via panel or PC cause/effect. Alarm Fault LEDs. Test alarms when switched to 0V. Engineer’s buzzer disable link for set-up or maintenance purposes. 24V DC power.

Windows-based PC Programming A Windows-based PC programming package is available for panel set up, zones, text, local and network cause/effect.

Typical Radio Pager Configuration The radio pager system, when connected to the control panel, can be used to transmit both text and numeric messages direct to pocket pagers. Pagers will display Fire / Fault conditions including Sensor location text. Up to 9,999 pagers can be connected to system. Connection to panel printer port. Transmitter Interface board Opto isolator

XP95 Test Tool The XP95 Test Tool is an engineer’s tool to assist with commissioning and fault finding on XP95 loop systems. Loop configurations and the status of each device may be interrogated, device LEDs may be turned on/off. The test tool may be connected to an entire loop without the panel connected or connected to individual devices around the circuit. Alpha-numeric LCD display. Sockets for flying leads to connect to loop and/or individual XP95 devices. Engineer’s keypad. Battery charger socket. On/off switch and LED indication.