DEMONSTRATION EXPERIMENTS

Slides:



Advertisements
Similar presentations
A.V. Koudinov, Yu. G. Kusrayev A.F. Ioffe Physico-Technical Institute St.-Petersburg, Russia L. C. Smith, J. J. Davies, D. Wolverson Department.
Advertisements

MR TRACKING METHODS Dr. Dan Gamliel, Dept. of Medical Physics,
Chapter 5 Light and Matter: Reading Messages from the Cosmos
School of Physics and Astronomy, University of Nottingham, Nottingham, NG7 2RD, UK. Electrically pumped terahertz SASER device using a weakly coupled AlAs/GaAs.
Remote sensing in meteorology
1 Chapter 27 Current and Resistance. 2 Electric Current Electric current is the rate of flow of charge through some region of space The SI unit of current.
Content Origins of Magnetism Kinds of Magnetism Susceptibility and magnetization of substances.
Cyclotron Resonance and Faraday Rotation in infrared spectroscopy
Chapter 19 NMR Spectroscopy. Introduction... Nuclear Magnetic Resonance Spectrometry is based on the measurement of absorption of electromagnetic radiation.
Lecture 3 INFRARED SPECTROMETRY
Metamaterial Emergence of novel material properties Ashida Lab Masahiro Yoshii PRL 103, (2009)
Electron Paramagnetic Resonance spectrometer
Fourier transform infrared spectroscopy[FTIR]
Medical Physics Physics 421 Course Description: Medical Physics is a course with two main parts:  Physics of the body  Physics of Diagnostic and Therapeutic.
© 2010 Pearson Education, Inc. Light and Matter: Reading Messages from the Cosmos.
Physical Chemistry 2 nd Edition Thomas Engel, Philip Reid Chapter 28 Nuclear Magnetic Resonance Spectroscopy.
Physical and Chemical Tests 10-1 Purification: Chromatography Distillation Recrystallization Comparison to known compounds: Melting point Boiling point.
INFRA RED ABSORPTION SPECTROSCOPY Kateřina Hynštová.
Antiferromagnetic resonance in frustrated system Ni5(TeO3)4Br2
A Comparison of a Mean Field Theoretic Approach to Ferromagnetism with Experimental Results Patrick Yarbrough- Department of Physics and Engineering The.
Spectral properties Colour of Transition metal complexes A substance exhibit colour because it has property of absorbing certain radiation from visible.
Electro-Optic Studies of Charge Density Wave Conductors Joseph W. Brill, University of Kentucky, DMR One-dimensional charge-density-wave (CDW)
Nuclear Magnetic Resonance Spectroscopy (NMR) Dr AKM Shafiqul Islam School of Bioprocess Engineering.
Vlasta Mohaček Grošev Training School on Raman Spectroscopy, COST Action MP 1302 “Nanospectroscopy”, Zagreb
Applications of polarized neutrons V.R. Skoy Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research Dubna, Moscow Region, Russia.
1 The Quantum Mechanical Model of the Atom Chapter 7.
Resolution Limits for Single-Slits and Circular Apertures  Single source  Two sources.
INFRARED SPECTROSCOPY
Introduction to Molecular Magnets Jason T. Haraldsen Advanced Solid State II 4/17/2007.
The HESSI Imaging Process. How HESSI Images HESSI will make observations of the X-rays and gamma-rays emitted by solar flares in such a way that pictures.
Ch 10 Pages ; Lecture 24 – Introduction to Spectroscopy.
OSU International Symposium on Molecular Spectroscopy June 18 – 22, TF Infrared/Raman -- TF01, Tuesday, June 19, 2012.
By Madhu Gyawali Narayan Adhikari Yadab Paudel FTIR Measurements on November 06,08 at Reno Nov 18, 08 PHYS 749 UNIVERSITY OF NEVADA, RENO,NV.
Nuclear magnetic resonance study of organic metals Russell W. Giannetta, University of Illinois at Urbana-Champaign, DMR Our lab uses nuclear magnetic.
An Experimental Approach to the Prediction of Complete Millimeter and Submillimeter Spectra at Astrophysical Temperatures Ivan Medvedev and Frank C. De.
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
NUCLEAR MAGNETIC RESONANCE
Copyright © 2009 Pearson Education, Inc. Biot-Savart Law.
Date of download: 6/22/2016 Copyright © 2016 SPIE. All rights reserved. Photographs of exposed femoral bone surfaces and surrounding tissue prepared for.
The Zeeman Effect in Mercury Casey Wall with Advisor Alan Thorndike Summer 2011 Purpose The purpose of this experiment was to observe the effect of a magnetic.
 FT-IR stands for Fourier Transform Infrared, the preferred method of infrared spectroscopy. In infrared spectroscopy, IR radiation is passed through.
Collin Broholm Johns Hopkins University and NIST Center for Neutron Research Quantum Phase Transition in Quasi-two-dimensional Frustrated Magnet M. A.
Presentation on.  There are many methods for measuring of fiber structure. Such as:  The absorption of infrared radiation  Raman scattering of light.
Electromagnetic interactions in a pair of coupled split ring resonators S. Seetharaman, I. R. Hooper, W. L. Barnes Department of Physics & Astronomy, University.
Electron Spin Resonance Experiment
Dec , 2005 The Chinese University of Hong Kong
Quantum Mechanical Model of the Atom
Raman Effect The Scattering of electromagnetic radiation by matter with a change of frequency.
Polarization Dependence in X-ray Spectroscopy and Scattering
Molecular Spectroscopy
Research stoichiometric of heterogeneity of lithium niobate crystals by IR spectroscopy Paranin V.D., Pantelei E.
The Refractive Index of a Solid
Biot-Savart Law.
الفيزياء د/هالة مصطفى احمد.
Optical Response of TES Bolometer Arrays for SAFARI
Gravitational Quantum States of Antihydrogen
Nuclear Magnetic Resonance Spectroscopy
Electro Optic Sampling of Ultrashort Mid-IR/THz Pulses
Advanced LIGO Quantum noise everywhere
Nuclear Magnetic Resonance
Medical Physics Physics 421 Course Description:
Nuclear Magnetic Resonance (NMR) Spectroscopy
10.3 NMR Fundamentals nuclear spin calculations and examples
Quantum squeezing of motion in a mechanical resonator
Thermal Photonics and Energy Applications
Val Kostroun and Bruce Dunham
الفيزياء الحيوية الطبية Medical Biophysics
Remote sensing in meteorology
CHEM 251 INORGANIC CHEMISTRY Chapter 4.
Chapter 19 NMR Spectroscopy.
Presentation transcript:

DEMONSTRATION EXPERIMENTS Magneto-optical far-infrared spectroscopy at the NSLS Diyar Talbayev (SUNY, Stony Brook), G. Lawrence Carr (Brookhaven National Laboratory), Laszlo Mihaly (SUNY, Stony Brook) INSTRUMENTS U12IR beamline of the National Synchrotron Light Source (NSLS) is dedicated to the study of optical properties of matter in the far-infrared spectral region. A fourier transform far-infrared spectrometer, a 16 T superconducting magnet, and the VUV synchrotron ring of the NSLS are the main components of the experimental setup . Magnet: Oxford Instruments 1 - 16 Tesla Vertical optical axis 37 mm sample space 1.3K-300 K temperature range Spectrometer: Sciencetech Martin-Puplett, step scan 0.01cm-1 (~ 100Gauss ) resolution 2 cm-1 to 1000 cm-1 spectral range Works with internal and (synchrotron) external sources The available equipment allows the users to measure the spectra of samples with the infrared light propagating along the magnetic field. The possibility of sending light through samples and perpendicular to the field is being implemented. With no external magnetic field, both reflection and transmission spectra of samples can be measured. In these measurements, a focusing mirror optics sample chamber that accommodates either a helium-flow (Helitran) or an immersion (Oxford Optistat) cryostat is used. The transition from transmission to reflection geometry is conveniently effected by moving only one mirror in the sample chamber. The mirror can be moved without disturbing any part of the chamber or venting it to the ambient pressure or. Liquid He cooled (4.2 K and 1.5 K) silicon bolometers detect the reflected or transmitted infrared light. In magnetic field only transmission measurements are possible with the presently available equipment. The superconducting magnet replaces the sample chamber, and a length of cylindrical light-pipes carries the spectrometer output light to the bottom window of the magnet. (See the figure on the right.) The light-pipe continues along the magnet axis, and samples are mounted inside the pipe. FUTURE PLANS Use unique ability to cover wide range of frequencies and fields with a calibrated intensity mapping. Identify the best magnetic field/frequency for Single Electron Spin Microscopy applications. Screen the samples to be studied Needed: Tenfold increase of resolution - high resolution FTIR spectrometer DEMONSTRATION EXPERIMENTS Antiferromagnetic resonance (AFMR) in LaMnO3 Magnetic moments on Mn3+ ions order antiferromagnetically below TN=140 K Measurement Conditions: Transmission geometry Driving H field of light perpendicular to ionic magnetic moments External field parallel to magnetic moments 15 - 180 K temperature range Sample: Oriented single crystal ~ 0.6 mm thick, 4.0 mm diameter disk Magnetic moments of Mn3+ ions are perpendicular to surface Time scales: A single frequency scan took about 15 min Complete mapping for fields 0-16 Tesla took 3 hours AFMR theory for pedestrians The classical picture of AFMR starts with the motion of a magnetic moment in a static magnetic field. Magnetic moment is usually associated with mechanical angular momentum, and the classical angular momentum equation of motion leads to the magnetic moment precession with frequency w=gH0 in the external magnetic field H0. In an antiferromagnet, we see two sublattice magnetic moments moving in external magnetic field plus the antiferromagnetic exchange field He and anisotropy field Ha. The combination of these fields results in a periodic motion of sublattice moments. The frequency of this motion in zero external field is w=g(Ha(Ha+2He))1/2. Figure 1 illustrates the resonance frequency behavior in non-zero external magnetic field along the easy axis of magnetization. The described motion of sublattice moments implies that the individual spins on each sublattice move collectively, each spin performing the same dance as any other spin. This is a particular case of the more general spin motion which is described in quantum language as magnons. Thus AFMR can alternatively be referred to as the magnon with k=0. Figure 2 shows the magnon dispersion curves in LaMnO 3 measured in neutron scattering experiments. The frequency at k=0 corresponds to the AFMR frequency in zero external field. (Neutron scattering frequency w » 0.6 THz = 20 cm-1; AFMR frequency w = 18 cm-1.) Fig 1. Low temperature spin-wave calculation of the resonance frequencies in the external field along the easy axis. Magnetic susceptibility c|| along the easy axis is taken to be 0. Measurement Results Figure 3 shows the transmission spectra of LaMnO3 sample taken with the setup in the spectrometer + magnet configuration. The curves represent the transmitted intensities at T=50 K with 7 T magnetic field and at T=180 K with zero and 1 T magnetic fields. Most of the structure in these spectra is inherent to the synchrotron radiation spectrum. The lower temperature spectrum, however, exhibits two AFMR absorption lines - one at 12 cm-1 and the other at 24 cm-1. We use the average of low field (0-2 T) high temperature (160 K, 180 K) spectra of the sample as a background spectrum and divide the spectra recorded at various sample temperatures and applied magnetic fields by this background. The procedure allows us to isolate the magnetic resonance absorption lines, and we get the frequency-field mapping of the magnetic resonance in LaMnO3. The frequency-field behavior of the resonance at different temperatures is shown in figure 4. Temperature range starts at 180 K and goes down to 15 K. The resonance frequency in the paramagnetic state, above 140 K, is proportional to the external magnetic field; this corresponds to the precession of magnetic moment in a static field. As the temperature goes below TN, the development of the sublattice magnetization gives rise to exchange and anisotropy fields, and we observe finite resonance frequency in zero field. In non-zero field at low temperatures the resonance line splits in two lines which correspond to sublattice magnetizations along and opposite the direction of the external magnetic field. Fig. 2. Magnon dispersion curves in LaMnO3 measured by neutron scattering. F. Moussa et al, Phys. Rev. B 54 15149 (1996) Fig 4. Dark purple regions correspond to AFMR absorption. Red line represents the paramagnetic resonance with g = 2. Fig 3. Red curve: H = 0 T, T = 180 K; blue curve: H = 1 T, T = 180 K; black curve: H = 7 T, T = 50 K LEES 02 International Conference, 13-18 October 2002