RO Demineralisers, Medium Flow

Slides:



Advertisements
Similar presentations
50Hz Stainless steel Vertical multistage centrifugal pumps
Advertisements

“The Major Breakthrough In Hard Water Treatment Technology”
FLUID BED GRANULATION SWITCH CABINET MANUFACTURER : GLATT AG
IMO 107(49)/46 CFR ppm Bilge Separators 15 ppm Bilge Alarms
A WORLD PRESENCE IN THE FIELD OF WATER
Filtersorb SP3 & Scale Prevention
Our World is Water Water treatment in container – with guarantee for quality and performance EUROWATER.
WATER SOFTENERS A Luxury that saves you Money. Problem - Hardness Water that contains high levels of dissolved calcium or magnesium salts, or both, is.
Water Treatment Processes Disinfection and removal of solids.
Australian water filter.
The Reverse Osmosis Seawater Desalination CONTAINER CONCEPT present.
Overview AST Clean water technologies was requested to design and construct an Industrial Waste water Treatment Plant with a capacity of 35 m 3 /h in.
MILK PLATE PASTEURIZER. Milk pasteurizer for instance the following thermal cycle or other, in relation with the product to handle. The plant will.
Innovative Design for Efficient and Reliable Filtration Systems.
Boilers.
Water Treatment Division Demineraliser equipment, production flow 4,5 m 3 /day Storage tank of 700 L included Suitable for water up to ppm (mg/L)
Power Plant Engineering
HVAC523 Heat Sources.
1 Clean Steam – The Basics Presenters: -Marie LaFrance, -George Godfrey,
KAUSAR AHMAD KULLIYYAH OF PHARMACY PHM3133 Dosage Design /11 1 Steam as a heating medium
Common Water Treatment Problems Hard Water -Calcium and Magnesium. Soap Scum, and Scale Build-Up. Iron - Clear (Ferrous), Red (Ferric), & Bacteria Related.
HEAT EXCHANGER GUIDED BY: PREPARED BY:
Technology Reverse osmosis technology is based on displacing salt water under high pressure (50-70 bar) through reverse -osmotic membrane which passes.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Customer Service – International Dept. The thermal solar systems  Installation  Commissioning  Maintenance.
Hydronic Balancing Balancing Valves
SAND CLEANING STATFJORD C FIELD TEST Stavanger 18 – 19 January 2006 Henrik Dannström, MATOR AS.
1 Kraft Fuels LPG Products & Services Your Logo Here Franz Keiling An Overview about LPG Dispensers and Technology Franz Keiling An Overview about LPG.
Service Export VICTRIX. VICTRIX Instantaneous boiler  VICTRIX 26 2 I Heating only prearranged for external cylinder connection  VICTRIX X 12 2 I  VICTRIX.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
INDIAN RAILWAY INSTITUTE FOR CIVIL ENGINEERS INTEGRATED COURSE, BATCH No 514 Water Treatment Through Reverse Osmosis System Presented by: 1. J. Gowri Shankar,
Dialysis Water Treatment Systems
Intel Water Reclaim Project Final Report 5/25/05.
BSAC Sports Diver Training
You can hardly find water which has no problem with one of 5 typical contaminants: Hardness Iron Manganese Natural organic matter (NOM) Smell of ammonia.
The SR Scale Remover For Cooling Water Treatment Without Chemicals.
MILK PASTEURIZER. One milk pasteuriser with a capacity of litres of milk for hours, HTST type with an operate range from 75° to 95°C, including.
References : PartA Ch.2 Sec.2 [5.6] PartA Ch.3 Sec.6 TNS 05 Boiler surveys.
STEAM CONDENSERS.
SINGLE-PHASE HOPPER LOADERS ENG. FEEDING SINGLE-PHASE FEEDER 2.
Water Purification Systems for Clinical Lab Prepared By Farid Khalaf.
THE BASICS of SFR Spot Free Rinse Systems - working to keep your reputation spotless  Spot Free Rinse water must have less than 40 ppm of TDS. Our preferred.
How to obtain fresh water Section - E6.3 Chemistry 12 – SL Isabelle R.
Membranes, Getting dirty and obturation Prevention or process delay
Rural Drinking Water Treatment System. INTRODUCTION Water demand Identification of water source Drinking water Quality Parameters Required treatment system.
DIVISION OF APPLIED TECHNOLOGIES NCSR “DEMOKRITOS” Innovative hybrid desalination unit for potable water production with simultaneous removal of harmful.
DIRECT INTEGRATION OF RENEWABLE ENERGY INTO A REVERSE OSMOSIS PROCESS.
Experts in Chem-Feed and Water Treatment Pre-Engineered Systems 1.
Water Treatment Division Wall mounted. Use of an antiscalant with automatic mixture preparation. Water softener only for boiler Production capacity can.
SETA Water treatment plant maintenance
Water Softener Systems Engineered Water Treatment Solutions.
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
Desalination for Drinking Water Purposes TCEQ Trade Fair David A. Williams, P.E Robert W. Sims, P.E. Austin, Texas May, 2016.
SPOT ZERO REVERSE OSMOSIS SYSTEM Welcome to Elite Marine Services.
Water Treatment Fundamentals. Agenda MEP Fundamentals (1 st badge): Ion exchange chemistry Softener designs and options Ion exchange capacity calculations.
WP 2 – Valorisation of Sludge
Challenges to avoid in Industrial Reverse Osmosis Systems.
Hub 4 Water Media Filters
Hub 4 Water Design, build, installation and servicing of all systems
REVERSE OSMOSIS PLANTS 5-35kl/day
Hub 4 Water Hub 4 Water Softener
REVERSE OSMOSIS PLANTS kl/day
Hub 4 Water Carbon Filters
Fulfilled the student of group ФЭ14-01B Zhuk Aleksey
Application Operation principle Advantages Highlights Comparison
Vertical Pressure Filters
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
Sea water Reverse Osmosis
T.S SEIUN MARU AUXILIARY BOILER Third Engineer 2019/2/19 ボイラ.
Terry A. Ring Chemical Engineering University of Utah
Presentation transcript:

RO Demineralisers, Medium Flow Demineralisers Medium Flow. Units available Mod. 4VA0X00: Cancelled Many membranes replaced in guarantee period. Corrosion problems due to high salinity Chlorine remover filter insufficient (chlorine damages the membranes) Few pre-treatments available Low Salinity Production (m3/day) 4VA0100 2.5 4VA0200 5 4VA0300 10 4VA0400 20

RO Demineralisers Medium Demineralisers Medium Production Capacity. Units available Mod. 4DAXX00: Available Equipments to process water from wells and brackish water, suitable to treat up to 2.500 mg/l (low salinity) and 9.000 mg/l (high salinity) of TDS, respectively. It can be mounted in a small cabinet Mod. 4045500 Optional production capacity increase with adittional membranes (1-4) Options: Chlorine remover filter, silex filter, iron remover filter, organic matter filter. Biocide doser, Bisulfite and water softener for boilers. Low Salinity High Salinity Production (m3/day) Membranes 4DA1100 4DA2100 4-6 1 4DA1200 4DA2200 8-12 2 4DA1300 4DA2300 14-18 3 4DA1400 4DA2400 20-22 4 Iron remover Filter Silex-antracite Filter Chlorine remover Filter Organic Matter Filter Biocide Doser Bisulfite Doser

RO Demineralisers Medium Demineralisers Medium Capacity. Units available in cabinet assembled-in Mod. 4015000 & 4016400 : Available Equipment with 2,5 m3/d (4015000) and 5 m3/d (4016400). Suitable for Jet-Wash centres. Optional devices for centres CAXX00 currently available Water softener is required Mod. 4015900, which supplies the boiler also. Mod. 4015000 Mod. 4016400 Mod. 4056600: Available Integration of Demineraliser 4034400 + Water Softner 4034300 Equipment with 4-5 m3/d and water softener 2x40L Optional device for one bay Jet-Wash centre 4CB0500 Water softener supplies RO and boiler. Mod. 4056600

RO Demineralisers Medium Demineralisers Medium Capacity. Available references in cabinet assembled for Jet Wash Nowadays, we offer for 4-6m3/ day : Old references for low salinity (4DA0100) Demineralisered water reserve tank 1000 l. (platform included) Water pump to supply high pressure units. Optional: 20” filter, Duplex Water Softener for boiler and demineraliser, thermal insulation and heater.

RO Demineralisers Medium Demineralisers Medium Capicity. Available references in cabinet assembled for Jet Wash Under development Mod. 4DA0300, it will be available for 4,5 m3 / day with the new technology: This model will replace the model (4DA0100) after a brief period of re-engineering. Pump for water to feed the high pressures included in the set. Optionals: Chlorine remover filter, Silex filter , Water Softner for heaters, thermal and heaters.

RO Demineralisers Medium Demineralisers Middle Capacity. Available references in assembled cabinet for Jet Wash Nowadays we offer for 10 m3 / day: Mod. 4DA1200 (low salinity) & 4DA2200 (high salinity) Reserve water tank placed outside cabinet Optionals are as follows: Chlorine remover filter, Silex filter, Water softener for boiler, Iron remover filter, Biocide doser, Bisulfite doser, thermal insulating and heater (pre-treatment filters depend on water analysis). Assembled into one or two cabinets, according to required pre-tratment.

RO Demineralisers Medium Models 4DAXX00. Main Features: Antiscalant doser instead of a water softener with salt. Antiscalant automatic mixture preparation. Backwash with demineralised water instead of feeding water. Advantages due to the use of antiscalant: Ecological: No brine from the water softner regeneration Logistics and easy use: no need to stack salt bags and simplicity Cheaper: antiscalant is cheaper than salt consumption Expansion of the action capacity: wide espectrum Balance in the ratio production/surface & reject/surface of the membrane compared with the old existing equipments.

RO Demineralisers Medium Models 4DAXX00. Main Features: Quality of components: Programmable PLC Siemens S7-200 Centrífugal Pump Grundfos Metering Pump Prominent Stainless steel frame quality AISI-304 Piping of High salinity range in stainless steel AISI-316 Toray membranes: TMG10 (Low salinity), TM710 (High salinity) Production can be upgraded just by adding membranes to the existing equipment (no need to buy a full new system). Suitable cabinet assembly Wide range of pre-treatments available:

RO Demineralisers Medium Models 4DAXX00. Balance Situation Customer How can we reach the balance between the three different interests? TAS Equipment

RO Demineralisers Medium Models 4DAXX00. Anomaly a) Minor Anomaly Those that require a TAS action, but they are not critical for the equipment operation. In this case, the equipment will alert with a buzzer, being this information registered in the PLC. From this moment, the customer has 10 days to inform to Istobal TAS, so they can proceed to the repair this anomaly, during these 10 days the equipment will keep on working. After this time the equipment will stop automatically, protecting itself from severe damages. Example: Antiscalant dosing failure. b) Serious Anomaly Those that require a TAS action, but being critical for the operation of the equipment. Therefore the system will stop immediately in order to avoid irreversible and expensive damages to the customer. Ejemplo: Water shortage, so the equipment must stop in order to avoid damages in the pump.

RO Demineralisers Medium Models 4DAXX00. Example of anomaly Just like a car, the models 4DA have two types of alarms to inform us about any possible failure and its seriuosness. CAR DEMINERALISER TYPE OF ALARM EXAMPLE ACTION NOT CRITICAL Windscreen wiper water shortage Amber light: to stop in a few miles Flow of demineralised water production, product dosing. Failure warning, failure record and equipment stop after 10 days. CRITICAL Motor oil shortage, brake fluid shortage Red light: immediate stop Water shortage, levels, overcurrent. To stop the equipment

RO Demineralisers Medium Models 4DAXX00. Main Features: Buzzer included to alert the customer about the failures. The equipment must recognize the adverse conditions to assure a long operational life. The demineralisers are equipments overlooked by the customer (is a non productive equipment) and usually there is not a preventive maintenance of these installations. The equipment will stop only if there is an imminent risk to its operating life, avoiding irreversible and expensive damages. The customer must be informed of any anomaly (critical or not) without decreasing the business. Light Alert Buzzer

RO Demineralisers Medium Demineraliser. Size. Height 2.000 mm Width 480 mm It is possible to be installed in cabinet Ref. 4033500 (size with cabinet: Height 2.100 mm x Width 1.500 mm x Depth 900 mm Length 1.550 mm

RO Demineralisers Medium Demineraliser. Available Configuration Assembly in Plant Configuration

RO Demineralisers Medium Maintenance of Demineralisers 4DAXXXX 1.- Daily maintenance To check the level of chemical product. 2.- Every week To check and to take note of pressures and flows. 3.- Every 3 months To check the condition of the filters (FS1 & FS2), if necessary they should be changed. 4.- Every 6 months To clean the small tanks of anti-scalant and backwash water.

RO Demineralisers Medium Example of calculation of Antiscalant vs Water Softener Antiscalant dosage Consumption of antiscalant product: Daily need of water: 21 m3 at 70 ºHF (39,2ºHD). “High” dosage of product: 5 mg/L = 5 g/m3 Daily product consumption: 21m3 x 5 g/m3 = 105 g/day = 0.105 kg/day 1 carafe 10 L = 13 kg So 1 carafe of 10 litres of antiscalant will last: 13 kg / 0.105 kg/day = 124 days Water softener 2x100 litres Salt Consumption: Daily need of water: 21 m3 at 70 ºHF (39,2ºHD). Necessary regeneration of the water softener every 9 m3 Number of regenerations per day: (21m3/day) / (9m3/ regeneration) = 2.3 regenerations /day Consumption of salt per litre of resin in every regeneration: 0,2 kg/Litres of resin Consumption of salt in every regeneration: 0,2 kg/Litre of resin x 100 Litres of resin = 20 kg of salt per regeneration Salt consumption per day: 2.3 regenerations / day x 20 kg of salt/regeneration = 46 kg/day Salt consumption in the same period of time (124 days): 46 kg/day x 124 days = 5. 704 kg = 228 sacks of 25 kg

RO Demineralisers Medium Example of calculation of Antiscalant vs Water Softener Conclusion: In 124 days of use: 5.704 Kg of salt = 1 bottle of 10 L (13 Kg) Make yourself your calculations: Price/kg Salt x 5.700 kg salt = Euros spent on salt versus PVP 10 L Antiscalant carafe = 189 ,00 Eur

RO Demineralisers Medium Difference between antiscalant and water softener. Antiscalant doser system + Antiscalant drum Water softener + Salt

RO Demineralisers Medium Car Wash Equipment Equipment performance 5m3/day 4DA1100 – Low salinity 4DA2100 – High salinity 10m3/day 4DA1200 – Low salinity 4DA2200 – High salinity 15m3/day 4DA1300 – Low salinity 4DA2300 – High salinity 20m3/day 4DA1400 – Low salinity 4DA2400 – High salinity M-7 M-9 + accumulation tank = 5 m3 M-15 = 10 m3 M-18 = 15 m3 4TB0100 4TB0400 = 15 m3 Range: Low salinity: 0 ppm– 2.500 ppm High salinity : 2.500 ppm – 9.000 ppm All R.O. equipments must be installed with a pretreatment stage according to the intake water quality !