Aishah Hazlina Md.Dean Jurutera Mekanikal

Slides:



Advertisements
Similar presentations
Bloodborne Pathogens Biological Safety Training Prepared by: Atef El-Gendy, PhD.
Advertisements

Biological Hazards Routes of Entry
ASEPTIC TECHNIQUE. PERSONAL PROTECTIVE EQUIPMENT includes: Eye protection Gloves Masks Gowns Sterile technique is employed to prevent contamination of.
Architectural Services Department HKSAR Laboratory Design for Secondary Schools.
Containment Equipment and Facilities. Biocontainment The principle of holding or being capable of holding or including within a fixed limit or area The.
Working Safely In Your Biological Safety Cabinet
Tulane University - Office of Environmental Health & Safety (OEHS) LABORATORY VENTILATION FOR TULANE LABORATORY EMPLOYEES January, 2005.
L ABORATORY SAFETY CABINET Dr Fadhl Alakwa
Chemical Fume hood or Biosafety Cabinet
Airflow and BSC Biosafety and Biosecurity Awareness Training
Fume Hoods. Objectives Overview of fume hoods Types of fume hoods Fume hood design definitions Fume hood operating performance and testing Sound work.
KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN
1 Utility Systems Process Systems – ‘Direct Impact Systems’ Contact the Product Contact Materials that will Ultimately Become Part of the Product Could.
Heating Ventilation and Air Conditioning (HVAC) – Part 3
VALIDATION OF HVAC SYSTEMS
Patient Safety Monitoring in International Laboratories (SMILE) 1 Biosafety in the Clinical Laboratory A SMILE Presentation.
Engineering Controls and Laboratory Design Session 4 Laboratory Safety Training.
Laboratory Ventilation. 2 Types of Laboratory Hoods  Constant Volume  Conventional  By-Pass  Auxiliary-Air  Reduced Air Volume  Variable Volume.
Welding, Cutting, & Burning. GENERAL HAZARDS General hazards of welding include: –Impact –Penetration –Harmful dust –Smoke –Fumes –Heat –Light radiation.
Local Exhaust Hoods. 2 Introduction:  Designed to capture and remove harmful emissions from various processes prior to their escape into the workplace.
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE
Providing services that help make The University of Memphis a safe and healthful place to learn and work Environmental Health and Safety.
Laboratory Safety-Fume Hoods 29 CFR Laboratory Safety Standard.
Siemens Building Technologies, Inc. ED&G 100 Design Project Fume Hood Face Velocity Control Spring 2004.
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
The Campaign for McMaster University Information Guide to Fume Hoods Facility Services (ext )
Types of Laboratory Hoods and Specific Uses. Horizontal Laminar Flow Cabinets SHC-A AHC-A.
LOCAL EXHAUST VENTILATION …study of the principles associated with proper application of local exhaust ventilation (LEV) for control of airborne contaminants.
Prepared by Farid Khalaf.  Protect the worker.  Protect the sample being analyzed.  Protect the environment.
Environmental Health and Safety
Industrial Ventilation - A major control measure Dr. AA, UTM.
Basic Principles of GMP Premises John Startup Training workshop: Training workshop on regulatory requirements for registration of Artemisinin based combined.
MCC PRESENTATION - GMP MANUFACTURING ENVIRONMENTS
Local Exhaust Ventilation
LABORATORY VENTILATION
Indoor Firing Ranges Training Education Recommended Practices.
Unit 6.4. Filtration TB Infection Control Training for Managers at National and Subnational Level.
Part 3: Design, qualification
This course has been supported by the President’s Emergency Plan for AIDS Relief (PEPFAR) through Centers for Disease Control &Prevention (CDC) under the.
Sterile preparation Facilities and Equipment Biological Safety Cabinet
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
Sterile Products Lab PHT 434
Bio-safety Cabinet Dr Fadhl M Alakwaa. Agenda What is bio safety cabinet (BSC)? BSC risks BSC Components. What is bio safety levels? Types of bio safety.
The Coudé Lab Environment Boulder 18 March The Coudé Lab.
Standard and Engineered Clean Air Solutions tailored to your laboratory needs 57 th Chaotic Meeting 11th May 2011.
Lab design Assignment 3 Unit 2.
Module 9Slide 1 of 25 WHO - EDM Premises Part One Basic Principles of GMP Part One, 11.
Containment Equipment and NSF 49. Containment – BMBL Primary containment is the protection of personnel and the immediate lab environment from exposure.
Exhaust Ventilation Level 4: Special considerations with very hazardous substances Part 2 of 2.
Sterile Products Lab PHT 434
Working safely with Biological materials Aseptic technique, sterilization and tissue culture techniques.
Testing Fume Hoods & Isolators Chemical Production & Development site Geel Michel Vangeel – EHS Department – October 2010.
Clean rooms HVAC System
Safelab Module 2 Biosafety Barry Byrne.
3 MANAJEMEN FASILITAS DAN KESELAMATAN ( SAFETY )
USP 797 Guidelines: Compounding Areas and Equipment
Author: Nurul Azyyati Sabri
CHAPTER 8 Ventilation.
FUME HOODS Welcome to an on-line
(Modified from University Of South Carolina)
Chapter 5- Facility Equipment
Biosafety Cabinet (BSC): What you need to know?
Aseptic Technique Definitions.
Compounding.
SAFETY CABINETS Welcome to an on-line
Fume Hood – Proper Handling of Chemicals / Proper Functioning
LABORATORY FAMILIARITY & SAFETY
Sterile Products Lab PHT 434
Laboratory Ventilation
Biosafety Principles: Separation, Seclusion & Containment
Presentation transcript:

Aishah Hazlina Md.Dean Jurutera Mekanikal KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN _______________________________________ Pengenalan kepada Peralatan Makmal dan Bilik Bersih (Clean Room) Aishah Hazlina Md.Dean Jurutera Mekanikal

LABORATORY EQUIPMENT FUME CUPBOARD BIOHAZARD SAFETY CABINET LAMINAR AIR FLOW CABINET

FUME CUPBOARD DEFINITION Define as “A partially enclosed work space that limits the spread of fume to operators and other personnel. It is ventilated by an induced flow of air through an adjustable working aperture that dilutes the fume and by means of an extract system, provides for the release of fume remotely and safely: BS 7258: Part 1: 1990

STANDARDS BS 7258 AS 2243 SAMA (Scientific Apparatus Manufacturers Assoc., USA

CLASSIFICATION/TYPE I) General Purpose FC II) Special Purpose FC - Class A - Class B - Class C II) Special Purpose FC - Perchloric Acid FC - Radioisotope FC

GENERAL PURPOSE FUME CUPBOARD CLASS A Used for materials of extreme toxicity or hazard. 125- 150 ft/min face velocity across sash (min. 100-125 ft/min) Treshold Limit Value (TLV) < 10 ppm

GENERAL PURPOSE FUME CUPBOARD CLASS B Used for most materials and operations in the laboratory 100 ft/min face velocity across sash (min. 80 ft/min) TLV 10-550 ppm

GENERAL PURPOSE FUME CUPBOARD CLASS C Used for materials or operations where the hazard is not high. 75-80 ft/min face velocity across sash (min 50-60 ft/min) TLV > 550 ppm

SPECIAL PURPOSE FUME CUPBOARD PERCHLORIC ACID FC Used only for Perchloric Acid compound application due to the potential explosion hazard of perchloric acid when combined with organic material. 125-150 ft/min face velocity across sash

SPECIAL PURPOSE FUME CUPBOARD RADIOISOTOPE FUME CUPBOARD Used for radioactive applications. 125-150 ft/min face velocity across sash

TYPES OF FUME CUPBOARD (AIR FLOW) CONVENTIONAL Allows only fixed sash opening AUTOMATIC AIR-BYPASS Allows the sash to be operated in various position and maintaining the required face velocity ADD/AUXILLIARY AIR - Addition of tempered outside air to provide the required face velocity and at the same time reduce the exhaust air-conditioning air

BIOHAZARD SAFETY CABINET

BIOHAZARD SAFETY CABINET Definition BS 5726-31 Define as “cabinet intended to offer some protection to the user and environment from the hazards of handling infected material, and other dangerous biological material, but excluding radioactive, toxic and corrosive substances”

STANDARDS DIN 12950 NSF. Std. 49 BS 5726 AS 2252 Pt. I (Class I) AS 2252 Pt. II (Class II) AS 2567 – Cytotoxic Drug Safety Cabinet US Fed. Std. 209c, Class 10

TYPE Class I – Designed specifically to provide operator/ personnel protection but do not protect product ( material being handled within the cabinet) Class II - Provides high level personnel,environment and product protection Class III - Operator is segregated from the work by physical barrier (gloves mechanically attached to the cabinet. Provides high level personnel, environment and product protection. Cytotoxic Cabinet - For both containment and asceptic manipulation. Provides protection for maintenance personnel as well.

Only personnel and environment protection NOT product CLASS I 100% exhaust cabinets with HEPA filtration Inward air velocity at the work opening 0.5-0.8 m/s Room air passes through the work zone and can contaminate product Air exhausted to the room Only personnel and environment protection NOT product

BIOHAZARD SAFETY CABINET – CLASS I

Personnel, environment and product protection CLASS II Part-recirculating LAF cabinets with HEPA filtration of exhaust air An air barrier at the work opening Separate fan/ HEPA filter systems for exhaust and LAF Vertical LAF recirculated in the work zone to protect products Air exhausted to the room Personnel, environment and product protection

BIOHAZARD SAFETY CABINET – CLASS II

Personnel, environment and product protection CLASS III Totally enclosed, 100% exhaust cabinets with HEPA filtration of supply and exhaust air All work within the work zone conducted through attached rubber gloves Air exhausted out from room In Europe, double filtration is common Personnel, environment and product protection

BIOHAZARD SAFETY CABINET – CLASS III

CYTOTOXIC DRUG SAFETY CABINET Partially recirculating Biohazard Safety Cabinet Class II with added protection for maintenance personnel Personnel (Operator), environment, product and maintenance personnel

CYTOTOXIC DRUG CABINET

LAMINAR AIR FLOW CABINET

LAMINAR AIR FLOW CABINET Definition Laminar air flow workstation is defined as an ultra-enclosure with a work zone which protect products from ambient contamination but which does not provide personnel and environment protection They are self-contained enclosures or cabinets incorporating fans and high efficiency HEPA filter Flow of air from the work space is blown directly into the laboratory either vertically downwards or horizontally towards operator

STANDARDS AS 1386, Pt.5 US Fed. Std. 209d, Class 100 BS 5295 Class I

TYPES 1) Horizontal Laminar Flow Cabinet - Laminar flow directed towards operator - Ambient air from room, filtered into the work zone - Velocity 0.45 – 0.5 m/s, +/- 20% of their average 2) Vertical Laminar Flow Cabinet - Laminar Flow directed vertically downwards towards product

HORIZONTAL LAMINAR AIR FLOW CABINET

CLEAN ROOM

DEFINITION US FED. STD 209B A clean room is an enclosed area employing control over the particulate matter in air with temperature, humidity, and pressure control, as required. Clean room must not exceed particulate count as specified in the air cleanliness class.

DEFINITION ASHRAE Chapter 15 A specially constructed enclosed area environmentally controlled with respect to airborne particulate, temperature, humidity, air motion, vibration, noise, viable organisms and lighting.

CLASSIFICATION OF CLEAN ROOM Class 1 Particles count < 1 particle/cu.ft (35 particles/cu.m) of a size 0.5 um Class 10 Particles count <10/cu.ft of a size 0.5 um and larger not exceeding 5.0 mm Class 100 Particles count <100/cu.ft of a size 0.5 um and larger

CLASSIFICATION OF CLEAN ROOM Class 1,000 (1K) Particle <1,000/cu.ft of a size 0.5 micron and larger Class 10,000 (10K) Particle < 10,000/cu.ft of a size 0.5 micron and larger or 65 particle/cu.ft of a size 5.0 microns and larger Class 100,000 (100K) Particle <100,000/cu.ft of a size 0.5 micron and larger, or 700 particle/cu.ft of a size 5.0 microns and larger

TYPES OF CLEAN ROOM A) Conventional or Non-Laminar Clean Room ( Turbulent Flow) B) Laminar Clean Room ( Laminar Flow) - Vertical Flow - Horizontal Flow

PENUTUP Peralatan Makmal dan Bilik Bersih hanyalah sebahagian kecil daripada Perkhidmatan Mekanikal yang terdapat di dalam sebuah bangunan khas (spt. Hospital, Makmal, Sekolah dll) Namun seperti juga perkhidmatan mekanikal yang lain, ianya merupakan nadi/penggerak bagi memastikan bangunan dapat berfungsi/hidup.

Sebuah bangunan tanpa mekanikal adalah ibarat badan yang cantik tetapi tidak bernyawa (body without soul). Cantik dari segi zahir tetapi tidak berfungsi. Perkhidmatan mekanikal-lah yang menghidupkan sesebuah bangunan itu. Terima Kasih