4.2 Bias, Standards and Standardization

Slides:



Advertisements
Similar presentations
Quality is a Lousy Idea-
Advertisements

Calibration methods Chemistry 243.
Stoichiometry Chapter 3. Atomic Mass 1961: Atomic Mass is based on 12 C 1961: Atomic Mass is based on 12 C 12 C is assigned a mass of EXACTLY 12 AMU 12.
Chapter 3: Calculations with Chemical Formulas and Equations MASS AND MOLES OF SUBSTANCE 3.1 MOLECULAR WEIGHT AND FORMULA WEIGHT -Molecular weight: (MW)
Errors in Chemical Analyses: Assessing the Quality of Results
CHAPTER 4 Stoichiometry. 2 Calculations Based on Chemical Equations How many CO molecules are required to react with 25 molecules of Fe 2 O 3 ?
Calculations with Chemical Formulas and Equations
Copyright©2000 by Houghton Mifflin Company. All rights reserved. 1 Chemical Stoichiometry Stoichiometry - The study of quantities of materials consumed.
Stoichiometry: Quantitative Information about chemical reactions.
Intro to Titrations. Volumetric Analysis Volumetric analysis is when the volume of a reactant required to complete a chemical reaction is measured. As.
Chapter 3 – Volumetric Analysis Week 1, Lesson 1.
Data Handling l Classification of Errors v Systematic v Random.
Titremetric analysis Dr. Mohammad Khanfar. Concept of Titremetric analysis In general, we utilize certain property of a substance to be analyzed in order.
Topic E conservation of atoms and mass
Quantitative Composition of Compounds Preparation for College Chemistry Luis Avila Columbia University Department of Chemistry.
Analysis & Stoichiometry Adv Higher Unit 2 Topic 1 Gordon Watson Chemistry Department, Kelso High School.
Chapter 13 Titrimetric Methods
Chemical Reactions. Balancing Chemical Equations- Problem Sodium metal reacts with water to produce aqueous sodium hydroxide and hydrogen. Sodium metal.
© 2010 Cerilliant Corporation | 811 Paloma Drive | Round Rock, TX Uncertainty in the micro-ROI measurement was estimated following the guidelines.
Solutions Solute Solvent Solutions are homogenous mixtures. When a substance is mixed with a liquid and it disintegrates into sub microscopic particles.
Chapter Four: Stoichiometry “ Stoichiometry is a branch of chemistry that deals with the quantitative relationships that exist between the reactants and.
Stoichiometry: Quantitative Information About Chemical Reactions Chapter 4.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
Quality WHAT IS QUALITY
Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.
Section Five Stoichiometric Calculations: The Workhorse of the Analyst.
Standardisation of Sodium Hydroxide solution
Chapter 5 Errors In Chemical Analyses Mean, arithmetic mean, and average (x) are synonyms for the quantity obtained by dividing the sum of replicate measurements.
Stoichiometry Calculations based on chemical reactions.
DETERMINATION OF AN UNKNOWN DIPROTIC ACID THROUGH VOLUMETRIC ANALYSIS
Quality Assurance How do you know your results are correct? How confident are you?
CHEMICAL ANALYSIS BY Dr.JAGADEESH. CHEMICAL ANALYSIS RESOLVING A SAMPLE IN TO ITS ULTIMATE COMPONENTS ( COMPOUNDS OR ELEMENTS)
IB1 Chemistry Quantitative 1b.. Topic 1: Quantitative chemistry 1.1 The mole concept and Avogadro’s constant Apply the mole concept to substances.
John A. Schreifels Chem Chapter 3 Calculations involving Chemical Formulae and Equations.
Stoichiometry! The heart of chemistry. The Mole The mole is the SI unit chemists use to represent an amount of substance. 1 mole of any substance = 6.02.
Solutions used in medical laboratory. O Solution is a homogeneous mixture of two or more substances. O Solute is the dissolved substance, whereas solvent.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Introduction The Equipment The Terms The Process Calculations
ERT 207 Analytical Chemistry ERT 207 ANALYTICAL CHEMISTRY Dr. Saleha Shamsudin.
U2 S3 L2 Titration page 603: Acid-Base Titration pages : Titration Step by Step page 838: Precision, Error and Accuracy Questions page 616: items.
GENERAL CHEMISTRY CHE 101 Lecture 3: Mass Relationship in Chemical Reactions Course Instructor: HbR.
Stoichiometry: Quantitative Information About Chemical Reactions Chapter 4.
Concept of volumetry. CHEMICAL ANALYSIS METHODS OF CHEMICAL ANALYSIS Volumetry Gravimetry Chromatography Atomic absorption spectrometry Potentiometry.
Chapter 1: The Nature of Analytical Chemistry
Unit 4 Solutions and Stoichiometry. Outline of Topics Solutions Solutions Molarity Molarity Dilution Dilution Introduction to Chemical Reactions Introduction.
For routine use, the biuret procedure is simple to perform, producing a stable color that obeys Beer's Law. UV-Vis Spectroscopy is primarily used.
Chapter Four: Stoichiometry Stoichiometry is a branch of chemistry that deals with the quantitative relationships that exist between the reactants and.
Chapter 13 Titrations in Analytical Chemistry. Titration methods are based on determining the quantity of a reagent of known concentration that is required.
Fundamentals of Analytical Chemistry Eighth Edition.
Solutions used in medical laboratory
Quality is a Lousy Idea-
Volumetric analysis. Titration.
The standard deviation (SD) quantifies variability
Chemical Calculations
Chapter 13: Titrations in Analytical Chemistry
Chemical Stoichiometry
Analysis of Iron Experiments 3, 19 & 20.
Quality is a Lousy Idea-
Chapter 3 – Volumetric Analysis
Chapter 10: The Mole.
1.0 Basic Concepts and Definitions
5.1 Introduction to Curve Fitting why do we fit data to a function?
Titrations & Ionization Constants
Introduction To Medical Technology
EXP. NO. 6 Acid Base Titration
Titrations & Ionization Constants
Pharmaceutical Analytical Chemistry-1 (PHC 103)
Presentation transcript:

4.2 Bias, Standards and Standardization bias and accuracy, estimation of bias origin of bias and the uncertainty in reference values quantifying by mass, chemical reactions, and physical methods standard reference materials primary, secondary and working standards methods of standardization: direct calculation, direct calibration, standard addition, internal standard, and calibration graphs 4.2 : 1/17

Bias and Accuracy Bias is defined as the difference between the "true" value and the mean of the pdf of the measurement. An accurate measurement is one that is more or less free of bias. An accurate measurement can have experimental error. However, the precision of the measurement affects our ability to estimate the mean of the pdf. It is often impossible to determine accuracy because the true value is unknown. To avoid this dilemma, true values are replaced by reference values. a real, although unknown, value such as Avogadro's number an assigned or agreed-upon value such as standard reference materials from NIST a value based on a definition followed by a series of experiments, such as the length of a meter. Only type (b) can be used to determine bias. 4.2 : 2/17

Mathematical Definition of Bias Let x be a measurement and R be a reference value. The total error is (x-R) which can be written as, (x-R) = (x-m) + (m-R) where (x-m) is the random error and (m-R) is the bias. Accuracy implies that m = R. For linear equations, the dependent random variable has a bias which is the sum of the individual biases. S = aA + bB + cC mS = amA + bmB + cmC mS-S = a(mA-A) + b(mB-B) + c(mC-C) Note that bias can be signed, thus it is possible for biases to cancel. If the individual measurements are free of bias, the linear dependent random variable is free of bias. 4.2 : 3/17

Estimation of Bias The t-test for one average can be used to identify the presence of bias. As an example consider the following data for the spectrophotometric determination of beryllium [John Mandel, The Statistical Analysis of Experimental Data, Interscience, New York, 1964, p. 123]. The sample was a NIST standard known to contain 3.179 mg beryllium. {3.167,3.177,3.177,3.169,3.173,3.177,3.177,3.177,3.171,3.169} avg = 3.1734 mg; std.dev. of data = 0.00409 Since tcalc > ttable, the measurement is biased. To estimate the range of the true bias, compute the t-interval about the bias mean. 4.2 : 4/17

Origin of Bias The most common source of bias for an inexperienced analyst is an error in understanding, or not following the procedure. A one-time procedural error is caught by analyzing replicates. A systematic procedural error is caught by analyzing standards. For an experienced analyst the most common sources of bias are uncalibrated instrumentation, impure reagents, and the application of a familiar technique to a new type of sample. Classification of bias into constant or proportional categories can often lead to identification of the error. Consider a spectrophoto-metric calibration curve. A constant error appears as a non-zero intercept. It might be due to an impurity in a buffer or an instrumental offset. A proportional error appears as an incorrect slope. It might be due to an impurity in the sample, or an incorrectly calibrated photometric scale. 4.2 : 5/17

Uncertainty in Reference Values The reference value is determined using two or more methods. The methods are chosen such that the expected sources of bias will be different for each method. The values are then compared with the t-test for two averages. If they are statistically indistinguishable it is doubtful that bias is influencing any of the values. Standards are also designed for specific methods of measurement, e.g. atomic absorption or ICP mass spectrometry. This helps ensure that the instrumentation is not biasing the result. Standards are prepared in matrices that are as close as possible to that found in the samples. For example, it is possible to purchase from NIST salmon containing known levels of mercury. Reference values will be provided with an upper bound for the total uncertainty: precision + bias. The analysis method will also be described in sufficient detail to minimize bias originating from changes to the procedure by the analyst. 4.2 : 6/17

Quantifying by Mass Large amounts of pure substances are expressed in moles, where 1 mole = 6.022141991023 0.000000471023 molecules. The number of moles is related to mass by the expression, moles = mass/molecular mass. The mole depends upon both the definition of atomic mass and the kilogram. Sample purity is a concern if a high level of accuracy is required. For example, an analytical balance with Class-S weights can determine 100.00000 g to an accuracy of 0.00025 g. A measurement limited by the balance would require a sample at least 99.99975% pure. At this level of accuracy sample-to-sample variations in isotope abundance can produce an error. The key mole standard for much of analytical chemistry is silver with an average mass of 107.8682 0.0002 g/mol. Silver has two important properties. (1) It has an isotope distribution which is virtually independent of mineral source. (2) It can be used to standardize HCl, reducing reagents, and precipitating reagents. 4.2 : 7/17

Quantifying by Other Methods If a substance is impure or otherwise un-weighable, it can often be quantified by a specific reaction and identification of the equivalence point. analyte + standard  products Equivalence point methods are not useful for low concentrations, or the reaction may not be sufficiently specific. The method is ultimately based on weighing the standard. Physical methods are preferred for small concentrations of analyte. As an example, Beer's Law relates concentration to sample absorbance. To use Beer's Law, the molar absorptivity needs to be known. The value of molar absorptivity is ultimately based on weighing a standard sample of the analyte. In this case the standard must be the compound of interest. This can be a severe restriction. 4.2 : 8/17

NIST Standard Reference Materials The National Institute for Standards and Technology (NIST) provides many services to the analytical chemistry community. calibration services for many types of instruments physical standards such as mass and length generation and archiving of standard reference data such as atomic masses standard reference materials (SRMs) that can be used to calibrate instrumentation There are four major considerations involved in certifying an SRM. homogeneity - every sub-portion of a lot has to be statistically representative of the whole stability - the reference value should not change with time handing procedures - special handling such as temperature certified values - the stated uncertainties include possible sources of bias as well as the propagation of precision 4.2 : 9/17

Standards and Certified Reagents A primary standard is a solid weighable compound which is used in equivalence point techniques. It has the following characteristics. the purity must be known and higher than the required accuracy of the analysis - usually 99.9% is sufficient it must be of known composition and react quantitatively with the analyte the composition should not change upon drying it and its salts should be soluble in water the molecular mass should be high Certified reagents have a specified purity and come with a listing of known contaminants. The ACS provides specifications for hundreds of reagents, and companies manufacture reagents to these specifications. This link shows the scope of ACS involvement in the certification activity: http://pubs.acs.org/reagent_demo/ 4.2 : 10/17

Example Reagents from Sigma standard base sodium carbonate produced by the thermal decomposition of sodium oxalate; sodium oxalate, ACS certified reagent, 99.5% tris-(hydroxymethyl) aminomethane (THAM or TRIS), primary standard, 99.9% standard acid potassium hydrogen phthalate, primary standard, 99.95% standard reductant sodium oxalate, ACS certified reagent, 99.5% arseneous acid, As2O3, primary standard, 99.95% standard oxidant potassium dichromate, ACS certified reagent, 99.0% potassium bromate, primary standard, 99.8% standard precipitant sodium chloride, ACS certified reagent, 99.0% silver nitrate, ACS certified reagent, 99.0% 4.2 : 11/17

Secondary and Working Standards Secondary standards are compounds that do not have all of the attributes of a primary standard but are still useful in equivalence point techniques or physical methods. sodium hydroxide cannot be quantified by weighing and reacts with CO2 in air and glass surfaces - requires repetitive standardization potassium permanganate is so reactive it needs repetitive standardization thiosulfate is eaten by air-borne bacteria Working standards have a low or unknown accuracy, but a stable response. Such standards are used to monitor instrumental drift, where the response is used to normalize time-dependent signals. 4.2 : 12/17

Direct Calculation This method of standardization is used when there is a known mathematical relationship between the measured response and the concentration. R = kC where R is the measured response, k is the known proportionality constant, and C is the analyte concentration. A good example is the titration of an unknown acid with a known base, where, mLacid and Mbase are known and mLbase is measured. one measurement per sample the standard and the analyte are different compounds cost effective for any number of samples 4.2 : 13/17

Direct Calibration This method of standardization is used when the measured response is known to be proportional to concentration, but the proportionality constant is unknown. R = kC An example would be spectrophotometry using Beer's law, A = elC where A is absorption, e is the molar absorptivity, l is the pathlength, and C is the molar concentration of analyte. The value of l is known, but e needs to be determined in a separate experiment. two measurements are required - standard and unknown the standard and unknown are the same compound cost effective when many determinations of the same compound need to be made 4.2 : 14/17

Standard Addition This method of standardization is used when the proportionality constant is unknown and matrix dependent. The analyte concentration is determined by a two-step process. (1) Run the unknown by itself. Ru = kCu (2) Run the unknown plus a small, known amount of analyte called the "spike." Ru+s = k(Cu + Cs) The concentration of the unknown is obtained by solving the two equations. two measurements are required the standard and analyte are the same compound not cost effective with many samples (it would be preferable to dilute into a solvent where a direct calibration could be used) 4.2 : 15/17

Internal Standardization This is a form of standardization used when the proportionality constant is time dependent. The temporal dependence is eliminated by using a ratio of responses measured simultaneously. The second compound must have the same temporal response as the analyte. Ru = kuf(t)Cu Rs = ksf(t)Cs First, known concentrations of both the analyte and standard are used to determine the time-independent ratio, K = kuf(t)/ksf(t) = ku/ks. Then the unknown and standard are measured simultaneously using the known value K. four measurements are required the standard and analyte are different compounds internal standards can be inefficient unless there is an easy way to make the simultaneous measurements 4.2 : 16/17

Calibration Graph This is a form of standardization used when the mathematical relationship between the measured response and concentration is unknown. R = f(C) A series of standards are prepared that are spread evenly over the range of concentrations expected for the unknown samples. When the functional form of f(C) is known but the equation constants are not, the calibration graph points can be curve-fit to obtain them. Once the constants are known, a direct calculation can be used. When the functional form of f(C) is unknown, the density of standards has to be sufficient that interpolation between points yields a valid value. requires many measurements the standard and analyte are the same compound only cost effective if many samples are analyzed 4.2 : 17/17