ADA Enhanced Condo Client: Kelly Heller Blind 48 years of age Sculptor

Slides:



Advertisements
Similar presentations
Code Analysis:Accessibility Colleen MacEachern & Stephanie Novak.
Advertisements

7 | Means of Egress (Life Safety Code)
Residential Building Codes and Preferences For the Designer Sleeping Area Architectural Design.
Texas Department of Licensing and Regulation
Cedar Property Management (509) Bedroom / 2 Bath 1240 Sq. Ft. Floor Plan Areas of Interest (#1) Hall BathHall.
Texas Department of Licensing and Regulation
INTD50A kitchen planning. a kitchen should be located near: the service entrance and dining area the cluster of rooms that creates the service area.
Objective: Develop plans for kitchen cabinets.
Wall Cabinets: Single Door 9-21" / Double Door 24-36"
Design for Elderly and Disabled Environments:
1 Room Planning Service Area.
Considerations for Special Needs Users Universal Design.
Creating a functional, aesthetic service area
1 Welcome to... Companion PowerPoint Presentation for the Introduction to Housing textbook.
Appliance Exam. 1. Energy Star appliances exceed minimum US Government energy standards by ______% or more? a. 15% b. 10% c. 30% d. 50%
Height = 34½ Depth = 24 Width in 3 multiples (15, 18, 21, etc)
Planning the Service Area
Architectural Design Copyright Texas Education Agency (TEA) 1.
Floor-Plan Dimensions and Notes
 Universal Design (UD) is about providing an affordable and attractive living space that everyone can use, including persons, families and friends of.
CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK’S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES DOWNLOAD THE.
Interior Elevations.
Proposed Changes to the ADA & ABA Accessibility Guidelines This presentation was prepared by the U.S. Access Board for the ADA Distance Learning 2000 program.
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
Universal Designers & Consultants, Inc. The Effect of the DOJ’s Newly Proposed ADA Standards (2004 ADAAG) on Hotel Design Universal.
1. Today’s Agenda Chapter 3: Building Blocks Chapter 4: Accessible Routes Chapter 5: General Site and Building Elements Chapter 6: Plumbing Elements and.
Visitability Standards Dan McNabb, Deputy Building Official Planning and Development Review Department.
Competency: Design and draw interior elevations for kitchens and baths Objective: Explain the elements of kitchen and bath design.
2004 Florida Accessibility Code for Building Construction
Sleeping areas: bedrooms, bathrooms, dressing rooms, and nurseries.
Kitchen Codes Luke Whaley Collin Schutz Aaron Thomas.
Planning & Designing A Kitchen. Step 1 Measure the Overall Room Draw a diagram of your kitchen, locating all windows and doors in their approximate positions.
AgeIn Place By: Kristin and Mayte. Kitchen Ideas  The kitchen has always been a place for family and socializing.  Making changes in the kitchen can.
Tom Kader Chief Electrical Inspector Spaces About Electrical Equipment Sufficient access and working space shall be provided and maintained about.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Space requirements And furniture.
DROP IN ANCHOR DETAIL COMMERCIAL SERIES LIFTS INSTALLATION MANUAL Drop In Anchor/COMMERCIAL SERIES.
Modifying Buildings to Meet the Needs of Seniors Housing Seniors in Rural America Resources, Advocacy and Practice Burlington, VT  June 6, 2012.
12/14/2011AEG Associates for the LTC Discussion Group  Presentation by Albert E. Graf, AIA AEG Associates, Annapolis, MD Building a Home Considering Universal.
Difference between 2003 and 2009 ICC/ANSI A117.1 applicable to the Plumbing Subcode Presented by: John N. Terry Tom Pitcherello.
Objective 1.03: Explain ways to adapt housing to meet special needs.
ACCESSIBLE BATHROOMS. GENERAL CRITERIA Use low flow, EPA's Watersense Program toilets Sensor control faucets to save water Lever handles on doors and.
ID 440: Project 1: Hospitality Design
Objective 1.03: Explain ways to adapt housing to meet special needs.
By Angela Forte, Michelle Gagnon, Kerri Morse, & Sam Oosterman.
Objective 1.03: Explain ways to adapt housing to meet special needs.
Chapter 2 Special Considerations in Design Special Populations The American with Disabilities Act of 1990 (ADA) Landmark Civil Rights case that represents.
(ACCESSIBILITY LAW) MINIMUM REQUIREMENTS FOR ACCESSIBILITY
Toilet design Many different regulations 1. guess what toilet features might be regulated? building code? accessibility code? universal design?
Toilet design Many different regulations 1. can you guess what might be regulated? building code? accessibility code? universal design?
Americans with Disabilities Act (ADA) Standards (Title II & III)
CHAPTER 1-HOMES & INTERIORS UNIVERSAL DESIGN. WHAT IS UNIVERSAL DESIGN? Universal Design Def.- A philosophy of designing interiors and products to accommodate.
Kitchens, Laundry Areas and Baths Chapter 22. Objectives 1. Explain basic principles for designing efficient kitchens, laundry areas and bathrooms. 2.
“My Room” Project The Massachusetts Code Book and the rules that apply.
House Project.
Remodeling tips to make your home more wheelchair and handicapped accessible.
Standard  Students will prepare residential floor plans.
Service Area Planning. Standard ACT-ADDI-1 Students will identify components related to the design process.
Garrett Plumstead Nick Pantelakis Eston slacks
Drawing Floor Plan.
7.01 Apply the elements of a functional kitchen design.
HUD’s 7 Requirements for Housing
Both D bathrooms and e kitchen What makes you special!
Bathrooms Interior Design I Objective 3.03.
J bathroom/ hi bedroom/ I kitchen
Building standards Mr. Da Silva.
Objective: Develop plans for kitchen cabinets.
Objective: Explain the elements of kitchen and bath design.
Objective 7.02: EXPLAIN the essentials of home baths
FARR’S BUILDING APARTMENTS
Presentation transcript:

ADA Enhanced Condo Client: Kelly Heller Blind 48 years of age Sculptor By Kaylee Bural Client: Kelly Heller Blind 48 years of age Sculptor Audiophile Entertainer

Floor Plan- 585sqft.

Kitchen Elevation

Kitchen/Living Room Elevation

Kitchen/Bathroom Elevation

Bathroom/Bedroom Elevation

Bathroom/Bedroom Elevation

Appliances/ADA Features 30” Single Wall Oven- Talking/Braille Buttons Single Drawer Dishwasher- Talking/Braille Buttons Microwave- Talking/Braille Buttons Shallow sink w/rear drain Custom roll-in shower Custom cabinetry- toe kicks/ knee clearance Custom Wardrobe

Perspective

Perspective

TAS Standards 306.2 Toe Clearance. 306.2.1 General. Space under an element between the finish floor or ground and 9 inches above the finish floor or ground shall be considered toe clearance. 306.2.2 Maximum Depth. Toe clearance shall extend no less than 17 inches and no more than 25 inches under an element. 306.2.5 Width. Toe clearance shall be 30 inches wide minimum. 306.3 Knee Clearance. 306.3.1 General. Space under an element between 9 inches and 27 inches above the finish floor or ground shall be considered knee clearance. 306.3.2 Maximum Depth. Knee clearance shall extend 25 inches maximum under an element at 9 inches above the finish floor or ground. 306.3.3 Minimum Required Depth. Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches deep minimum at 9 inches above the finish floor or ground, and 8 inches deep minimum at 27 inches above the finish floor or ground. 306.3.5 Width. Knee clearance shall be 30 inches wide minimum.   308.2 Forward Reach. 308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches maximum and the low forward reach shall be 15 inches minimum above the finish floor or ground. 804.2.1 Pass Through Kitchen. In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 40 inches minimum. Pass through kitchens shall have two entries. 804.3 Kitchen Work Surface. In residential dwelling units, at least one 30 inch wide minimum section of counter shall provide a kitchen work surface. 804.3.2 Height. The kitchen work surface shall be 34 inches maximum above the finish floor or ground. 804.6.6 Refrigerator/Freezer. Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches maximum above the ground. The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset 24 inches maximum from the centerline of the dedicated space. Advisory 608.1 General. Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. 608.2.1 Transfer Type Shower Compartments. Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915 mm) wide minimum entry on the face of the shower compartment. Clearance of 36 inches (915 mm) wide minimum by 48 inches (1220 mm) long minimum measured from the control wall shall be provided. 608.3.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry. Grab bars shall not be provided above the seat. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls. 804.6.3 Dishwasher. Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the dishwasher or the sink. 804.6.4 Range or Cooktop. Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306. Where knee and toe space is provided, the underside of the range or cooktop shall be insulated or otherwise configured to prevent burns, abrasions, or electrical shock. The location of controls shall not require reaching across burners.

TAS Standards (Continued) 1. A parallel approach complying with 305 shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided and to wet bars. 2. A lavatory in a toilet room or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to provide knee and toe clearance complying with 306. 3. In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the fixture; (b) the finish floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4. A knee clearance of 24 inches (610 mm) minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches (785 mm) maximum above the finish floor or ground. 5. A parallel approach complying with 305 shall be permitted to lavatories and sinks used primarily by children 5 years and younger. 6. The dip of the overflow shall not be considered in determining knee and toe clearances. 7. No more than one bowl of a multi-bowl sink shall be required to provide knee and toe clearance complying with 306. 606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground. 1. A lavatory in a toilet or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 606.3. 2. In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted where rough-in plumbing permits connections of supply and drain pipes for sinks mounted at the height of 29 inches (735 mm). 606.4 Faucets. Controls for faucets shall comply with 309. Hand-operated metering faucets shall remain open for 10 seconds minimum. 606.5 Exposed Pipes and Surfaces. Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks