PowerShield Battery Monitoring Systems protecting your power supply

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

Remote Monitoring and Control System
eGenKit Remote Monitoring Solution
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
CL100D series DSP controlled Uninterruptible power supplies.
RiT PatchView Solution
5387 Avion Park Drive Highland Heights, Ohio INTUNE v4.4 Demonstration.
1 Effective, secure and reliable hosted security and continuity solution.
Ultimate Bundle Overview Products Benefits Technical Requirements Licensing Pricing Valid until 01-Sep-2010.
Sentinel Battery Monitoring Systems protecting your power supply P r o t e c t i n g y o u r p o w e r s u p p l y1.
Static Transfer Switch
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
DATA ACQUISITION SmartLog X3 DescoEMIT.com Rev:
Model B1 19-inch Rack Static Transfer Switch. Why choose a model B1 static transfer switch? Increases power availability. True solid state. Rugged, reliable.
VSE Corporation Proprietary Information
Lighting and Wastewater Controls Smithfield Foods Engineering.
OVERVIEW TEAM5 SOFTWARE The TEAM5 software manages personnel and test data for personal ESD grounding devices. Test and personnel data may be viewed/reported.
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
RF500 Wireless Monitoring  Exceptional data integrity  Complete peace of mind.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
April 2004 page 1 Confidential and propietary CentraLine Portfolio c l o s e t o y o u.
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
Predictive Maintenance: Condition monitoring Tools and Systems for asset management September 19, 2007.
Copyright 2009 GxP Automation, LLC Welcome Complete Automation Solutions for Critical Facilities.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
During a mains supply interruption the entire protected network is dependent on the integrity of the UPS battery as a secondary source of energy. A potential.
Made in United States of America EMIT SIM emit.descoindustries.com Rev:
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
Front Page …..is an Asset Management tool designed to record and aid the analysis of activities affecting Production capability and costs. …..promotes.
Battery Monitoring Fundamentals & Experience
Net Optics Confidential and Proprietary Net Optics appTap Intelligent Access and Monitoring Architecture Solutions.
ENVIROTRAC: A Premier Chamber Monitoring and Data Acquisition System Envirotrac A Guided Tour.
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
FOX AVL SYSTEM Satellite vehicle locating, tracking and fleet management.
The Sentry Personal Alarming Dosimeter and Rate Meter.
DataMaster 3000 Data Acquisition and Control Software.
Battery Monitoring Systems. Permanent monitoring solution designed for stand-by batteries Complete package including hardware & software Designed to allow.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Design Team : Advisor: Dr. Edwin Project Web Site: Client: Paul
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
PowerShield Battery Monitoring Systems protecting your power supply P r o t e c t i n g y o u r p o w e r s u p p l y1.
Rohde & Schwarz Topex TOPEX IP Radio Gateway July 2011.
FLATPACK Rev.5 September 2002 Updated versions may be available.
Aeon Gold – System Overview *TCP/IP *SNMP Aeon Gold Display Unit *Advanced setup and *monitoring through *WinPower *SW Download PC w /WinPower Aeon 4000.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
Common Problems with Performance/Testing of Batteries
Interfaces 101 Interfaces provide connectivity for the drawers to virtually any POS device (printer, terminal, tablet etc.) in the industry.
People Inc. from P&A Software
PRESENTS.
Sentinel Battery Monitoring Systems protecting your power supply
Avaya VA Line-interactive UPS
IP-based 8-port Switched Power Manager
Battery Monitor Data Manager Demonstration
Technology that lets you Trust your batteries!
Programmable Logic Controllers (PLCs) An Overview.
Nlyte for Colocation Providers
People Inc. from P&A Software
PLC / SCADA / HMI Controllers: Name : Muhammad Zunair Comsats University Date: 28-October-2018.
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Data Centre Environment
Integrated gateway-server
REDUCE OPERATION COSTS
Field installable, upgradeable and scaleable
Presentation transcript:

PowerShield Battery Monitoring Systems protecting your power supply

PowerShield - Data Center Solutions Permanent monitoring solution designed for stand-by batteries Complete package including hardware & software Designed to allow IEEE/IEC best practice Fast, accurate, safe & smart Visibility of your battery assets Be in control of your batteries. P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y In the Battery Room Modular layout for safety, efficiency, scalability - Sentinel controller + m-Senzor battery sensors Up to 1280 blocks / 16 strings per hardware system Stand-alone system operation with on-board memory Can operate without PC or external comms UL, CUL, CE, C-Tick, FCC, KCC certified Fast & tidy installation Battery & UPS brand neutral Maintain manufacturer flexibility & capability for future expansion P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y In the Battery Room All parameters sampled continuously & automatically Rapid identification of catastrophic failures Automatic data logging Allows historic & predictive trending over battery lifetime Automatic data logging of battery discharge Live assessment of performance Capacity analysis UPS self-test & intermittent charging compatibility Make best use of UPS functionality All events and alarms time & date stamped P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y At the Battery Individual block voltage, sampled simultaneously every 4 seconds True real-time visibility Individual block impedance, sampled daily Sampled only in Float for best comparison & life trending Internal high precision reference for self-calibration Individual block temperature option Measured at negative terminal as per IEEE recommendations Accurate & block specific thermal runaway detection P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y At the Battery 750VDC optical isolation at battery Increased safety of personnel & facility Install flexibility & efficiency – consolidate different block & string voltages [UPS, 48V, genset, emergency lighting] Factory terminated cable sets with no fusing required Intelligence at the battery Ripple & noise rejection Self-protection Bi-colour LED for fast identification No more manual battery testing. P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y Raising the Alarm Alarms for block voltage, impedance & temperature [thermal runaway]; string voltage & current; ambient temperature All alarm settings user-editable, but with initial defaults offered Self-learnt automatic baseline for impedance All alarm settings are battery & application specific Detailed, specific alarm information – to individual block level System intelligence applies appropriate limit set for battery state – Float/Charge/Discharge/Idle Notification of change of string state Alarms for internal system diagnostics P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y In the Control Room Alarm & data options for data center integration: Ethernet to PowerShield Link software Allows review at all levels – control room, facility managers, service providers, equipment suppliers. Both life trend and discharge event data presented Battery data stays under your control & ownership ModbusRTU/TCP or SNMP to local building management system Integrate with existing facility systems Allows implementation of multiple alarm sets Dry contacts for additional alarm outputs or actions Dedicated serial port for local service & diagnostics High visibility & ownership of your battery assets. P r o t e c t i n g y o u r p o w e r s u p p l y

Accessing Your Battery Data P r o t e c t i n g y o u r p o w e r s u p p l y

PowerShield Link Software New Dashboard screen for Link – see all the batteries in your facility at a single screen. Fast overview Onscreen alarm pop-ups Single click for site report Simple colour coded buttons Drill down to battery specific detail & alarms Multi-seat, multi-user P r o t e c t i n g y o u r p o w e r s u p p l y

PowerShield Link Software Permanent connection to multiple sites – unlimited total number of batteries Real time battery status, including discharge Remote access via LAN Alarm & activity log Email alarm alerts Battery database for life trending Graphing & analysis tools Automated data management Battery management is more than just waiting for alarms P r o t e c t i n g y o u r p o w e r s u p p l y

PowerShield Link Software Comprehensive user report set Preformatted PDF or Raw CSV data Facility summary Discharge – individual events in detail, activity summary Trending – Impedance change, end-of-life, charge voltage, temperature Alarm history, fault tracking, service log Warranty claim support documentation Reports suitable for management & service teams Independent remote Reporting Service available P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y PowerShield Users Equinix – Hong Kong, Singapore, Australia, New Zealand HP – Austin TX, Australia IBM – Australia, New Zealand, UK, South Africa, France Bank of America – UK, Hong Kong, Singapore, Australia Microsoft - Ireland Huawei - China Bloomberg - global Barclays Bank – UK "PowerShield gives us the confidence to get on with running our business with the peace of mind that, should there be a power outage, our backup battery is in A1 condition."  - Television New Zealand P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y PowerShield Ltd Developing battery monitoring solutions since 1996 In-house hardware & software teams Strong R&D team with continuous product development and battery research Independent of battery & UPS suppliers CTO is working group member of the IEEE Stationary Battery Committee. Current Vice Chair of IEEE 1491 Guide for Selection and Use of Battery Monitoring Equipment in Stationary Applications. P r o t e c t i n g y o u r p o w e r s u p p l y

P r o t e c t i n g y o u r p o w e r s u p p l y PowerShield Ltd Global reach, local focus PowerShield technical & reseller support in territory – USA, Singapore, UK Stock holdings – USA, Singapore, UK Factory trained installation partners globally support@ - direct access to factory support if required www.powershield.com P r o t e c t i n g y o u r p o w e r s u p p l y

Notes: What We Measure & Why Individual block voltage – ensure correct charge and performance under load Individual block impedance – impedance change gives a solid life trend and end of life assessment. Ambient temperature at the cabinet/rack – high temperatures kill batteries. A 10°C increase gives a 50% decrease in life expectancy String current – allows detection of unbalanced strings, and provides rapid understanding of battery activity String voltage – confirmation of UPS operation & compliance with battery specification Individual block temperature [optional] – better knowledge of temperature gradients in cabinets; pre-empt thermal runaway P r o t e c t i n g y o u r p o w e r s u p p l y

Looking After Your Batteries A 10°C increase gives a 50% decrease in life expectancy P r o t e c t i n g y o u r p o w e r s u p p l y

Looking After Your Batteries Incorrect float voltage significantly affects life expectancy P r o t e c t i n g y o u r p o w e r s u p p l y