Datacenter Health Check Terri-Lynn Thayer AVP/CIO, Computing & Information Services EDUCAUSE Enterprise Technology Conference, May 2007.

Slides:



Advertisements
Similar presentations
Challenges in optimizing data center utilization
Advertisements

Data Center Design Issues Bill Tschudi, LBNL
Save Time, Money, and Energy by Virtualizing Your Environment Mica Lyman and Shawn Harpe Oklahoma State University Copyright Mica Lyman, Shawn Harpe 2007.
1 Procuring a Design Project engineers perspective on starting the design process and establishing the A/E scope of work Frank C. Quigley General Engineer.
What Does the Net Generation Expect From Us? SAC August 8, 2005 SAC August 8, 2005 Copyright © 2005, Joel L. Hartman. This work is the intellectual property.
Student, Faculty, and Staff Data Availability and Protection What’s the Back-Up Plan? (for academic computing) Sponsored by.
© Copyright Computer Lab Solutions All rights reserved. Do you need usage information about your computer labs? Copyright Computer Lab Solutions.
VSE Corporation Proprietary Information
Cooling Strategies for Small IT Rooms Presented by Jim Magallanes TechniCool Innovations Inc Upham Street Suite B-1, Broomfield.
Disaster Recovery Planning Because It’s Time! Copyright Columbia University and Bentley College, This work is the intellectual property of the author.
Zycko’s data centre proposition The very best products and technologies Focus on what your customers need Turning products into solutions Wide range of.
IST 346 Chapter 6 Data Centers.  What is a datacenter?  Page 129, “ a data center is a place where you keep machines that are a shared resource”  A.K.A.
Achieving Data Center Availability along with Efficiency by Management Systems Shimon Katz, Data Center Project Manager ELECTRICITY 2012 – Eilat, Israel.
Cloud Computing Data Centers Dr. Sanjay P. Ahuja, Ph.D FIS Distinguished Professor of Computer Science School of Computing, UNF.
Telenor Tier 3 Data Center April About Telenor Tier 3 Data Center Telenor built it´s own Data Centar in accordance with the latest industrial standards.
IBM Energy & Environment © 2008 IBM Corporation Energy Efficiency in the Data Centre … and beyond Peter Richardson UK Green Marketing Leader.
Virtualization Across The Enterprise Rob Lowden Director, Enterprise Infrastructure Indiana University 23 May 2007.
Return of the Large Data Center. Computing Trends Computing power is now cheap, power hungry, and hot. Supercomputers are within reach of all R1 universities.
Measuring and Validating Attempts to Green Columbia’s Data Center October 14, 2010 Rich Hall Peter M Crosta Alan Crosswell Columbia University Information.
02/24/09 Green Data Center project Alan Crosswell.
Thermal Management Solutions from APW President Systems
An Academic Data Center Build Out at the University of Michigan Paul Killey Tempe, AZ Feb
Schneider Electric IT Business North America Advancing Date Centers around Life Cycle Management. May 2011.
 Site  Requirements  Local Resources  Initial layout ideas  Brief material selection  Supply options.
Data Center Design Christopher Geyer. A Data Center Highly secure, fault-resistant facilities housing equipment that connect to telecommunications networks.
Copyright Statement Copyright William F. Hogue, This work is the intellectual property of the author. Permission is granted for this material to.
Commodity Data Center Design
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Data Center Construction Project Updates and Experiences Gary Stiehr May 6, 2008 HEPiX Spring 2008.
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
Getting Green Building Automation. Why is Building Automation a Green Technology? There are programs starting all over the nation that focus on alternative.
Data Center Services Facilities Management Production Support Operations.
IST 346 Chapter 6 Data Centers.
CSG Panel – May 10, 2006 Key Lessons for New Data Centers Project overview Requirements Lessons learned Going Forward.
Copyright Michael White and Sandra Thompson, This work is the intellectual property of the author. Permission is granted for this material to be.
Best Practices in HVAC Design/Retrofit
Energy and Industry Trends Dave Molin VP & General Manager Honeywell Building Control Systems.
Physical Infrastructure Issues In A Large Centre July 8 th 2003 CERN.ch.
Progress Energy Corporate Data Center Rob Robertson February 17, 2010 of North Carolina.
Infrastructure Gina Dickson – Product Manager Kevin Jackson – Sales Manager.
Dealing with Hotspots in Datacenters Caused by High-Density Computing Peter Hannaford Director of Business Development EMEA.
Welcome Georgia Infrastructure Transformation 2010 Kick-off Meeting January 30, 2008.
Nikhef/(SARA) tier-1 data center infrastructure
High Performance Computing (HPC) Data Center Proposal Imran Latif, Facility Project Manager Scientific & Enterprise Computing Data Centers at BNL 10/14/2015.
Authors: William Tschudi, Lawrence Berkeley National Lab Stephen Fok, Pacific Gas and Electric Company Stephen Fok, Pacific Gas and Electric Company Presented.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Disaster Recovery: Can Your Business Survive Data Loss? DR Strategies for Today and Tomorrow.
Optimizing Power and Data Center Resources Jim Sweeney Enterprise Solutions Consultant, GTSI.
Physical Security Concerns for LAN Management By: Derek McQuillen.
Hot /Cold Aisle Containment  Traditional Data Center/Telco designs are changing significantly!
1 ITM 1.2 How IT Decisions Impact Data Center Facilities: The Importance of Collaboration Lars Strong P.E. Upsite Technologies, Inc.
West Cambridge Data Centre Ian Tasker Information Services.
Dell EMC Modular Data Centers
Free Air Cooling for Data Centres
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Renovate the Data Center
A Path to the Community Cloud Making Above Campuses Services a Reality
Unit 2: Chapter 2 Cooling.
Using Heat to Increase Cooling George Hannah BEng (Hons) CEng MIMechE
CERN Data Centre ‘Building 513 on the Meyrin Site’
Data Center Service Brian Messenger 11/15/2016.
Luigi SCIBILE on behalf of the CERN SMB-SE group
GES SYSTEM THE IMPORTANCE OF GES SYSTEM IN BUILDING
Cloud Computing Data Centers
Blaine A. Brownell, President,
Architecture for Modular Data Centers
Cloud Computing Data Centers
The Greening of IT November 1, 2007.
Data Centre Environment
Approaching the Data Center Project
Presentation transcript:

Datacenter Health Check Terri-Lynn Thayer AVP/CIO, Computing & Information Services EDUCAUSE Enterprise Technology Conference, May 2007

Copyright Terri-Lynn B. Thayer 2007 This work is the intellectual property of the author. Permission is granted for this material to be shared for non-commercial, educational purposes, provided that this copyright statement appears on the reproduced materials and notice is given that the copying is by permission of the author. To disseminate otherwise or to republish requires written permission from the author.

Presentation Overview Datacenter blood pressure is rising Pre-assessment work Reliability goals Assess existing space, power, cooling, fire suppression, & security Assessment results & options Recommendations for a renovation Key considerations in site selection

Datacenter Blood Pressure is Rising Growing Demands Increased number of servers Increase in breadth of customer base – taking in previously distributed computing Technology Changes Storage growth Power/cooling needs – new boxes are smaller but they are energy hogs and they are hot, hot, hot (10X power for a fully populated rack and 3-4X power to cool it down) Business Resumption Concerns 24 x 7 demands Well publicized disasters - 911, Katrina Many university datacenters today lack standby power generation Research Support National trend for R1s to take on more support centrally Our Datacenters are Old

Pre-Assessment Work Capacity Planning and Growth Analysis Determine a planning horizon Identify services likely to be provided from your datacenter during that time period Business Continuity and Disaster Recovery Objectives How long can your University operate without a functioning datacenter? Do you have a cold or hot site? Should you consider a multiple datacenter approach?

More Homework Research computing support decision is fundamental Review your insurance How much do you have Other requirements of your insurer Get professional help with the assessment Involve your university facilities engineers Seek advice from outside professionals who are familiar with modern datacenter design and operation What cost/risk profile is your institution comfortable with? Reliability goals

BRUNS-PAK Data Center Reliability Ranking BRUNS-PAK 999 NEW DURHAM ROAD EDISON, NJ (732) Fax: (732)

Datacenter Evaluation Space Electrical System Mechanical System Fire Protection System Security

Space Square footage of conditioned space Raised floor Access Elevators Door size Machine room layout Furnishings, racks, command center Is the space expandable? Is this a multi purpose facility?

Electrical/Power Considerations Source and costs Patch Panel/Power Control Units/ Power Distribution Units Standby power Uninterruptible Power Supply (UPS) Redundant/non-redundant Battery type (wet vs dry), capacity, and monitoring Generator Type Power and cooling Are the systems expandable? Delicate balance Other Surge protection, lightning protection, grounding

Mechanical Systems Evaluation Cooling & humidity control Chilled water – do you have a dedicated chiller? Computer Room Air Conditioner - CRAC units - # and location Capacity and reliability Heat Detectors Airflow distribution Water sensors

Fire Protection Systems Detection Smoke alarms Heat detectors Air sampling Abatement Halon system (production banned in 1994) Full flooding clean agent system FM-200, NAF, Inergen etc Sprinkler system Wet Pre-action

Security Physical access to the facility elevators & doors Caged areas and visitors Multi-purpose facility Door access system Windows Monitoring Closed circuit TV

Ancillary Services and Support Ancillary Services Tape storage Secure storage/staging Paper storage Test/setup lab Printers and print support General storage room Break room Other staffing and services which are provided from your datacenter Machine hosting and associated SLAs others University departments groups external to the University

Assessment Results & Options Most of us will find that our datacenters are not adequate for the anticipated growth over the next five years Majority will identify power and cooling as the most significant issue Cooling and the power to cool will be the number one issue Space constraints will be the runner up

Options Renovate Build a new datacenter Both of the above Multi-datacenter campus Outsource or Hosting

Recommendations for Renovation Implement standby power generation capable of supporting both power and cooling Remove ancillary services from machine room and relocate to other spaces Trade off between space and density is a complex issue High density racking results in significant heat and power provision issues It is general cheaper to provide more space than to keep a small space with high density equipment adequately powered and cooled

Improve Air Flow & Circulation Provide additional space between racks to promote air circulation Open up plenum space by relocating cabling to overhead trays Increase height of the raised floor if possible Consider new cooling solutions and rack technologies – everything old is new again Chilled water is far more efficient than cool air for heat removal Reconfigure the layout to implement a double hot aisle/cold aisle configuration Distribute high density racks

Double Hot Aisle/Cold Aisle hot aisle/cold aisle layout is where cold air is segregated in front of equipment cabinets and hot exhaust air is expelled behind equipment cabinets. This layout eliminates the direct transfer of hot exhaust air from one system into the intake air of another system Double A CRAC unit is located between two hot aisles

Site Selection for a New Facility An opportunity to consider cost Corporate world has moved their datacenters in some cases quite remote from the rest of their operation which allows them to consider Power costs Real estate cost Labor costs

Look for a Old Supermarket Single story Single use facility Slab Few windows Lots of open space around the building Loading docks and delivery truck access

Other Considerations Voice and data connectivity Flooding and other weather related issues If moving to a multi-datacenter approach as part of a business continuity plan then consideration should be given to put the two datacenters at a sufficient distance to reduce dependence on the same power grid and to minimize weather and other regional disasters

Staffing Implications Data Center Managers will need to be more skilled in the area of environmental issues, engineering, and server technologies Facilities organizations may need to devote more time and specialization to cooling and power technologies related to the datacenter Managing data center renovation or build projects will be resource intensive and may result in downtime for key services

Go Green Reduce energy costs (datacenter build may be more expensive) Legislation Environmental concerns and institutional plans to reduce carbon emissions Vendor products Rack and server cooling technologies CO2 for cooling, DC power systems Design Considerations Solar panels and wind energy Heat recycling

Conclusion Our datacenters are under significant stress If we take a close look we will find that most of us will experience power and cooling problems in the near future. Cooling and the power to cool will be the most substantial issue we face. There are new technologies and best practices which will provide some relief Many of us will build new datacenters over the next five years and we should consider remote locations, outsourcing, and green IT solutions These project will require both significant financial resources as well as IT and Facilities staff time. We may need to employ new skill sets It is highly recommended that you engage professional assistance to evaluate your facility and to assist in renovation and new build designs

Additional Resources Past Meetings Spring 2006 meeting Data Center Futures Workshop Presentations