LCLS Injector Diagnostics

Slides:



Advertisements
Similar presentations
Coherent Radiation from High-Current Electron Beams of a Linear Accelerator and Its Applications S. Okuda ISIR, Osaka Univ Research Institute.
Advertisements

Paul Emma LCLS FAC April 16, Initial Experience with Injector Commissioning P. Emma, et al. Facilities Advisory Committee.
P. Emma, SLACLCLS Commissioning – Sep. 22, 2004 Linac Commissioning P. Emma LCLS Commissioning Workshop, SLAC Sep , 2004 LCLS.
P. Emma, SLACLCLS FAC Meeting - April 29, 2004 Linac Physics, Diagnostics, and Commissioning Strategy P. Emma LCLS FAC Meeting April 29, 2004 LCLS.
Hamid Shoaee LCLS FAC Review – October Control System Overview Hamid Shoaee Controls System Manager Injector control system commissioning & Support.
Cecile Limborg-Deprey Injector Commissioning September Injector Commissioning Plans C.Limborg-Deprey Gun exit measurements.
Henrik Loos High Level 17 June 2008 High Level Physics Applications for LCLS Commissioning Henrik Loos.
Cecile Limborg-Deprey Injector October Injector Physics C.Limborg-Deprey Diagnostics and Commissioning GTL measurements.
Injector Accelerator Readiness Review, 10/31/06 Henrik Loos 1 Beam Losses During LCLS Injector Phase-1 Operation Scope of phase 1 operation Operating modes.
IPBSM status and plan ATF project meeting M.Oroku.
Injector Setup/Mini-phase  Description of injector setup  sources of drift  Mini-phase procedure for injector  Checking the rest of the machine. Stephen.
Low Emittance RF Gun Developments for PAL-XFEL
A. Doyuran, L. DiMauro, W. Graves, R. Heese, E. D. Johnson, S. Krinsky, H. Loos, J.B. Murphy, G. Rakowsky, J. Rose, T. Shaftan, B. Sheehy, Y. Shen, J.
SPPS, Beam stability and pulse-to-pulse jitter Patrick Krejcik For the SPPS collaboration Zeuthen Workshop on Start-to-End Simulations of X-ray FEL’s August.
LCLS Accelerator SLAC linac tunnel research yard Linac-0 L =6 m Linac-1 L  9 m  rf   25° Linac-2 L  330 m  rf   41° Linac-3 L  550 m  rf  0°
S. Molloy, P. Emma, J. Frisch, R. Iverson, M. Ross, D. McCormick, M. Woods, SLAC, CA, USA S. Walston, Lawrence Livermore National Laboratory, CA, USA V.
Diagnostics Overview for the LCLS Presented by Josef Frisch For the LCLS ANL / LBNL / LLNL / SLAC.
NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3,
An electron/positron energy monitor based on synchrotron radiation. I.Meshkov, T. Mamedov, E. Syresin, An electron/positron energy monitor based on synchrotron.
Henrik Loos LCLS ICW October 2006 Diagnostics in the LCLS LCLS Injector Commissioning Workshop October 9-11, 2006 Henrik.
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
Wir schaffen Wissen – heute für morgen PSI, March 2013 Paul Scherrer Institut PSI / DESY / KIT Mini-Workshop on Longitudinal Diagnostics for FELs.
PAL-XFEL Commissioning Plan ver. 1.1, August 2015 PAL-XFEL Beam Dynamics Group.
Applications of transverse deflecting cavities in x-ray free-electron lasers Yuantao Ding SLAC National Accelerator Laboratory7/18/2012.
Bunch Length Monitor Development
LCLS_II High Rep Rate Operation and Femtosecond Timing
Emittance measurements for LI2FE electron beams
Multi-bunch Operation for LCLS, LCLS_II, LCLS_2025
Summary of SPARC first-phase operations
Slice Parameter Measurements at the SwissFEL Injector Test Facility
Have a chance to operate your own beam at CERN
OTR based measurements for ELI-NP Gamma Beam Source
Accelerator Physics and Engineering Update Jan 6, 2010
Beam-Based Feedback in LCLS-II
Thermal emittance measurement Gun Spectrometer
Application of a Streak camera at PITZ
The Cornell High Brightness Injector
LCLS Linac Update Brief Overview L1 & BC1 Progress LTU & E-Dump Status Continuing Resolution Impact.
What am I working on… H. Loos 08/02/2010.
LCLS Gun Commissioning Status & Plans David H
Profile measurements at CTF
Diagnostics overview and FB for the XFEL bunch compressors
Accelerator Physics and Engineering Update Jan 6, 2010
Beam size diagnostics using diffraction radiation
LCLS bunch length monitor utilizing coherent radiation
Injector Commissioning C
Linac/BC1 Commissioning P
LCLS Linac Overview E. Bong Lehman Review August 10, 2004
LCLS Commissioning P. Emma, et al
High Level Physics Applications for LCLS Commissioning
Linac Diagnostics Patrick Krejcik, SLAC April 24, 2002
CLIC Feasibility Demonstration at CTF3
Injector Experimental Results John Schmerge, SSRL/SLAC April 24, 2002
Linac Physics, Diagnostics, and Commissioning Strategy P
Breakout Sessions SC1/SC2 – Accelerator Physics
Transverse coherence and polarization measurement of 131 nm coherent femtosecond pulses from a seeded FEL J. Schwenke, E. Mansten, F. Lindau, N. Cutic,
Maximum Credible Beam Event Paul Emma et al
LCLS Injector/Diagnostics David H. Dowell, SLAC April 24, 2002
Breakout Session SC5 – Control Systems
Diagnostics RF and Feedback
Linac Diagnostics Commissioning Experience
Operational Experience with LCLS RF systems
LCLS Injector Commissioning P
Undulator Cavity BPM Status
Diagnostics overview Beam profile monitors Cherenkov radiators Summary
Injector Diagnostics Status
Linac Design Update P. Emma LCLS DOE Review May 11, 2005 LCLS.
LCLS Longitudinal Feedback System and Bunch Length Monitor Juhao Wu Stanford Linear Accelerator Center LCLS DOE Review, February 08, 2006 LCLS longitudinal.
Breakout Session SC3 – Undulator
Experience with photoinjector at ATF
Presentation transcript:

LCLS Injector Diagnostics Henrik Loos Diagnostics overview Transverse Beam Properties Longitudinal Beam Properties

LCLS Diagnostics Tasks Charge Toroids (Gun, Inj, BC, Und) Faraday cups (Gun & Inj) Trajectory & energy Stripline BPMs (Gun, Inj, Linac) Cavity BPMs (Und) Profile monitors (Inj), compare position with alignment laser Transverse emittance & energy spread Wire scanners YAG screen (Gun, Inj) OTR screens (Inj, Linac) Bunch length Transverse cavity + OTR (Inj, Linac) Coherent radiation power (BC) Slice measurements Horizontal emittance T-cavity + quad + OTR Vertical Emittance OTR in dispersive beam line + quad Energy spread T-cavity + OTR in dispersive beam line

LCLS Injector Diagnostics YAG, FC YAG Toroid T-Cavity Phase Monitor Wire Scanner Toroid OTR Toroid OTR YAG

Diagnostics Through BC1 RF Gun & Solenoid L0a&L0b S-Band Linacs T-Cav Sec 29 Transverse RF Cavity Bunch-Compressor-1 (BPM, OTR, collimator) OTR & Wire Scanners Gun Spectrometer L1 S-Band Linac Wire Scanners + OTR 135 MeV 250 MeV TD-11 stopper X-Band RF Straight Ahead Spectrometer Bunch Length Diagnostics 40 m

Transverse Diagnostics YAG scintillator OTR Wire Scanners

Requirements for YAG & OTR Monitors Name Location Hor. Beam Size (mm) Ver. Beam Size (mm) Resol. (µm) YAG01 GTL 1.400 [7.0] [6.0] 15 YAG02 0.460 YAG03 L0 0.410 YAGG1 3.340 [45.0] 1.500 [8.0] 30 YAGS1 SAB 0.030 0.060 YAGS2 [10.0] 0.100 [12.0] OTRH1 DL1 0.180 0.380 40 OTRH2 0.200 0.280 OTR1,3 0.125 0.130 OTR2 0.065 OTR4 0.160 [1.5] 0.120 [14.0] 25 OTRS1 7 Name Location Hor. Beam Size (mm) Ver. Beam Size (mm) Resol. (µm) OTR11 BC1 3.800 0.100 30 OTR12 0.040 1.000 13 OTR21 BC2 2.600 0.050 16 OTRTCAV L3 0.070 [1.0] OTR30 DL2 0.010 [0.2] 0.025 3 OTR33 OTRDMP Dump 0.075 0.060 [0.6] 20 Large 50mm crystal required for gun spectrometer. Zoom lens needed. Requires foil with and angle of 5 deg to the beam and a likewise tilted camera to keep the entire screen in focus.

YAG Beam Profile Monitor Yellow scintillator crystal, emits green light when charged particle passes through Fluorescence decay time 70ns High photon yield Nφ = 3.5 /e- For 1 nC charge: Nφ = 2 1010 ~108 Photons at 5pC Plenty of photons to detect with a CCD 100µm thickness to meet resolution Saturation at high charge densities Saturation limit 0.04 pC/µm2 Equals 65 µm beam size at 1 nC Combined with Faraday cup in GTL -> camera shielding Thin mirror (1mm) at higher energies Mirror e- θ YAG Lens CCD

Transition Radiation Radiation of a charged particle at relativistic speed moving from one medium into another. Relativistic speeds -> Coulomb field is quasi-electro-magnetic wave. Vacuum-metal boundary -> Field is reflected and emitted in 1/γ angle Light intensity linear to bunch charge Emission is instantaneous and free of saturation effects Metal Foil Electron Beam 2 γ θ

OTR yield for 100mrad angular acceptance OTR Profile Monitor Small quantum efficiency About 1 photon/100 electrons Logarithmic dependence on energy and solid angle Aluminum foil 1µm Mitigates radiation issue Foil damage is concern Limited z-space Foil at 45 degree Depth of field ~1mm Match reflection direction with TCAV or dispersion direction OTR yield for 100mrad angular acceptance Energy (MeV) QE (%), 450-650 nm 135 0.44 4300 0.98 13500 1.17

Optics Layout Used for all standard YAG/OTR screens Telecentric lens 55mm focal length >100 line pairs/mm Magnification up to 1:1 with extender Mounting of camera enables field of view from 5 to 20 mm Stack of 2 insertable neutral density filters Beam splitter and reticule for in situ calibration Megapixel CCD with 12bit and 4.6µm pixel size Radiation shielding in gun region Vacuum Filters Lens CCD OTR e-beam Reticule YAG Beam splitter Illumination

OTR/YAG Optics Design Actuator Optics Box CCD Lens Filters Screen Beam Splitter Reticle

OTR Imager for 135 MeV Spectrometer Need wide field of view in focus for measurements in spectrometer beam line Tilt OTR screen and CCD by 5 degrees in 1:1 imaging 12um resolution tested Device ready to install No actuator, rate limit required for beam into spectrometer line

CCD Camera and Lens Test Uniq Vision CCD Dark Image Test TECM55 lens with ruler (scale 1/64”) Periodic BG structure removed with background subtraction Background noise 2 bits rms Dynamic range > 100 Resolution: B/W transition < 20um

Profile Monitor Controls x CCD Image YAG Crystal Rows y Rate limit electron beam Single bunch & burst mode Prevent foil damage and limit camera irradiation Profile monitor hardware control Chassis for actuator, filters, illumination EPICS driver ready Camera control (EPICS) Cameralink and EPICS IOC Buffered acquisition@10Hz Screen update @1Hz Image processing (Matlab) Flip image to match image coordinates with beam Background subtraction Automated image cropping Beam size calculation Different algorithms implemented Gaussian fit Baseline cut, etc. Mock-up

Software Development Matlab EPICS

Profile Monitor Commissioning Tasks Verify correct image polarity and calibration. Compare with alignment laser, BPMs and wire scanners. Find proper attenuation filter for YAG profile monitors. Determine beam center with alignment laser.

Wire Scanner Status Requirements Hardware status Software Step size 5um Accuracy 2um, reproducibility 10um Tungsten wire 20um to 60um, matched to beam size Hardware status Wire scanners for injector tested to meet specs and calibrated Photomultipliers with charge integrating ADCs tested Software Low level EPICS Calibration tool Scan user interface to select 1 or more wires Buffered acquisition linked to timing system High level Matlab Software for normalization with toroid and jitter correction with BPM Profile analysis and emittance calculation same as for profile monitors

Requirements Area IN20 LI21 LI24 LI27 LI28 LTU Total Scanners 4 3 1 19

Distance Measurement (LVDT or similar) Design - Mechanical Distance Measurement (LVDT or similar) Motor Beam Limit Switches

User Interface - Operations

Bunch Length Monitoring Transverse Cavities are the Gold standard Provide single shot energy vs. time, with excellent resolution (<5 micron bunches measured at TTF2/FLASH) Invasive – can only measure at a low repetition rate Used to calibrate other measurements Coherent mm-wave radiation power detectors Used a full rate for uncalibrated feedback measurement. Other systems may be used to reduce need for transverse cavity based calibration – but not baseline Electro-optical measurement Optical spectrum statistical measurement

Transverse Cavity Bunch Length Measurement TCAV in injector @ 135 MeV Low field of 1.4 MV sufficient Invasive measurements on OTR2, 4, S1, YAGS2 TCAV in sector 25 at 5.9 GeV in ‘08 Max field of 25 MV Parasitic measurement with horizontal kicker and off-axis OTR Horizontal Kicker Vertical Deflecting Cavity Off-axis Screen Electron Beam

Injector TCAV TCAV tested successfully at full gradient in klystron lab 3MW, 120Hz, 3us pulse 2MW, 120Hz, 3us pulse was requirement

Transverse Cavity Calibration Temporal resolution limited by beta function, RF power, screen size Calibration with TCAV phase scan Calibration accuracy limited by phase jitter TCAV injector: >>20 slices possible TCAV linac: <5 slices due to limited RF, non-dedicated optics, screen resolution Mock-up Mock-up

Software Development

Bunch Length Monitor Relative bunch length measurement used for longitudinal feedback Non-intercepting, calibrated with interceptive TCAV measurement Based on integrated power from coherent radiation source (C*R) Single electron radiation spectrum W1(ω) depends on radiation source Bunch length determined by long wavelengths λ » 2πσrms BC1: 1cm – 1mm BC2: 1mm - .1mm BC1 BC2

Millimeter Wave Gap Radiation Single Shot (assuming single shot spectrometer, or multiple detectors) Non-Invasive Simple high rate readout – can use signal from single detector Very simple, low cost Low noise readout <1% RMS demonstrated Diode detectors work to ~300GHz -> ~200 micron bunch length Possibly can be extended to ~ 1THz, ~70 micron bunch length Provides only relative measure of bunch length To be installed after BC1.

Layout of Gap Radiation Measurement

Millimeter-wave gap monitor tests in End Station A Output of 100GHz detectors as phase (bunch length) is adjusted M. Woods SLAC Comparison of 2, 100GHz detectors for a range of operating conditions RMS difference 1.4% for 10,000 pulses

Millimeter Wave Coherent Synchrotron Radiation Single Shot (assuming single shot spectrometer, or multiple detectors) Non-Invasive Measures from arbitrarily short to ~mm bunches (with appropriate filters). Simple high rate readout – can use signal from single detector with input filter Measures power spectrum (no phase information) – cannot reconstruct bunch shape Variations on spectral response must be calibrated using external bunch length measurement – not practical to provide a calibrated signal To be installed after BC1 and BC2.

BL11 Millimeter-wave CER bunch length monitor Mirror with hole after bend to collect synchrotron radiation stripe Reflective optics (off-axis parabolas) to collect and transport light Beam splitting filter for high pass / low pass to 2 mm-wave detectors Different filters available Compare power on detectors for (uncalibrated) bunch length measurement Similar in concept to gap monitor, but bend and collecting optics give larger (>X10) signal, at cost of increased complexity Need higher signal for short bunch measurements where diode detector do not work

Layout of CER Bunch Length Monitor

Detector Setup for BL11

Bunch Length Sensitivity of Detector Signal Detection efficiency includes diffraction, vacuum window, water absorption, pyroelectric detector response, and bunch form factor. Introduce high and low pass filters at 10cm-1 and 20cm-1.

Optical Synchrotron Radiation Noise Measurement P. Catravas et al, Physical Review Letters 82 (1999) 5261 1.5ps. 200-500pC, 44MeV beam using a spectrometer with a resolution of 0.05nm/pixel 1.5ps 4.5ps RMS distribution measurement does not require calibration Non-invasive Not single shot Will test after BC1 Can upgrade to (near?) single shot measurement using optical spectrometer