T.S SEIUN MARU AUXILIARY BOILER Third Engineer 2019/2/19 ボイラ.

Slides:



Advertisements
Similar presentations
An Introduction To Marine Steam Propulsion Plant [Source: US Navy]
Advertisements

Maintenance Shows of America April 2010 Tampa Florida Presented By: Byron Nichols Representing: The American Society of Power Engineers.
ACTIVE LEARNING PROCESS
Power Plant Engineering
Fired And Unfired Pressure Vessels
Energy Efficient Steam Systems
Mountings & Accessories
Boiler Operation Procedures
Boilers Dept. of Mech & Mfg. Engg..
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Watertube Boiler.
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
Cooling As working temperatures rise, the strength of metals used reduces. This in turn will force manufacturers to use superior metals/alloys, which can.
FIRE FIGHTING PROCESS HAZARDS
Boiler Mountings.
Lesson 17 Marine Boiler.
Steam Boilers UNIT-VI.
 Latent heat  Sensible heat  Total heat  Specific heat.
Group Meeting #1 January 29 th, 2013 Michael Bentel Jeremy David Erik Peterson Arpit Shah 1.
Section 16.3 Using Heat.
Steam Power Plant.
References : PartA Ch.2 Sec.2 [5.6] PartA Ch.3 Sec.6 TNS 05 Boiler surveys.
Marine Engine Systems Merchant Marine Training Centre.
POWER PLANT.
STEAM CONDENSERS.
Lesson 7 Steam Power Plant.
B OILER Presented by: Muhammad Azffar Mohamad Hanif bin Yusof Nor Aminah bt. Mohd Khalil
Theory of Steam Generation P M V Subbarao Professor Mechanical Engineering Department Progressive Development of Power Generation through Steam Generation……
Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam at the desired temperature and pressure.
Gas Turbine Power Plant
STUDY OF BOILER’S ACCESSORIES
Practical Energy Conservation Tips for Steam Propulsion Ships.
Boiler Mounting Made by : Group 2 Electrical Eng-B.
1. - Condensate pump and feed pump trip! -Turbine trips! 2.
Prepared by : Guided by : Mr. Tanmay Patel.
1 Combustion Efficiency Test. 2 Principles 1.Composition of flue gases 2.Flue gas smoke concentration 3.Temp of flue gas 4.Draft produced 5.Excess combustion.
Section 3 Using Heat.
Heat engines played a key role in the development of the modern industrial world. Steam locomotives were an important early use of the steam engine. Electric.
Welcome PRESENTATION BY ASHISH MISHRA.
STEAM POWER PLANTS.
THERMAL POWER PLANT. INTRODUCTION : THERMAL POWER PLANTS CONVERT THE HEAT ENERGY OF COAL INTO ELECTRICAL ENERGY. COAL IS BURNT IN A BOILER WHICH CONVERTS.
BOILER MOUNTINGS & ACCESSORIES
CERTIFICATE This is to certify that the project work entitled “Different Power Plants“ Is being submitted by Name of the student : Enroll no.: Patel Akshaykumar.
Prepared by : Nishant .A. Raval
WELCOME TO SHARING SESSION - 3. I NDIAN INTRODUCTION TO IBR R EGULATION B OILER 1950.
Thermal power plant , panipat
Energy Balance across pulverizer is very critical for satisfactory
Lesson 7 Steam Power Plant.
Unit 13 Oil-Burning Equipment
Review Questions Chapter 5
- Condensate pump and feed pump trip!
Gas Power Plant - Layout and Operation
POWER PLANT THERMAL POWER STATION.
Low-power boiler robots
Fulfilled the student of group ФЭ14-01B Zhuk Aleksey
Furnace Heat Transfer & Steam Generation
______________ Combustion Engine
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
Furnaces (also called Fired Heaters)
- Condensate pump and feed pump trip!
Rajan Bhandari Senior Lecturer
First Exam is on March 21 Examples are posted on the course website !
3. Boiler Mountings Rajan Bhandari.
Classification & Types of Boilers
AIR COMPRESOR Chapter-13.
WATER AND STEAM SYSTEM.
MERC TRAINING ACADEMY BOILER SPEFICATIONS.
Boiler Room LOG Sheets: Interpreting the Records
Feed Water Treatment for Steam Power plant
Presentation transcript:

T.S SEIUN MARU AUXILIARY BOILER Third Engineer 2019/2/19 ボイラ

PREFERENCE OF AUX’ BOILER 蒸気出口 ガス出口 2019/2/19 ボイラ

PERFORMANCE OF AUX BOILER Type:MITSUBISHI MC-30D Steam pressure :0.59MPa Feed water temperature :60℃ Evaporation :3000kg/h Main Fuel :C heavy oil 2019/2/19 ボイラ

ARRANGEMENT Water drum (top) Evaporation tubes Soot blower Inspection hall Access Door Outlet for exhaust gas Oil burner Water drum (bottom) Furnace 2019/2/19 ボイラ

Atmospheric Condenser Boiler FO Supply Pump Supplies FO or DO from each service tank to FO burning pump. Forced Draft Fan Supplies air for combustion, pre­purge and post­purge on aux. boiler Soot Blower Operation for Removing the soot attached on the heating tubes of aux. boiler or exh. gas economizer with steam. It has done in periodically to keep the thermal efficiency and prevention of getting damage of heating tubes. Inspection Tank Inspects the oil incorporation into the drain from heating steam drain. So called as Observation tank too. Feed Filter Tank Removes the oil and impurity materials from condensate water (boiler feed water). Atmospheric Condenser As a role , condensation the steam drain from the tank-heating line and several heaters with low temp cooling fresh water. 2019/2/19 ボイラ

BOILER FO SYSTEM 2019/2/19 ボイラ

BURNER FRONT IGNITER BURNER FDF MOTOR 2019/2/19 ボイラ

SAFETY VALVE 2019/2/19 ボイラ

Feed Water Control Valve 給水を制御する 2019/2/19 ボイラ

WATER LEVEL GAUGE 2019/2/19 ボイラ

STEAM SERVICE LINE 2019/2/19 ボイラ

AUTOMATIC COMBUSTION TIME CHART 2019/2/19 ボイラ

BURNER AUTOMATIC OPERATION 《 START 》 IGNITION to MAIN BURNER STEAM PRESS UNDER 0.49MPa START FO BURNING PUMP & F.D.F. PRESSURE RISE EXTINCTION PILOT BURNER PRE - PURGE ( 90 sec ) IGNITION to HIGH/LOW BURNER IGNITION to PILOT BURNER STEAM PRESS REACH to 0.59MPa WORKING of FLAME EYE EXTINCTION HIGH/LOW BURNER 2019/2/19 ボイラ

STEAM PRESS REACH to 0.62MPa BURNER AUTOMATIC OPERATION 《 STOP 》 STEAM PRESS REACH to 0.62MPa EXTINCTION MAIN BURNER & STOP FO BURNING PUMP POST – PURGE ( 60 sec ) STOP F.D.F. 2019/2/19 ボイラ

About the important word・・・ ・PREPURGE This operation is for ventilation before the ignition to prevent a backfire . ・POSTPURGE This operation is for ventilation after the extinction to remove the remaining gas inside the combustion chamber. This operation prevent the corrosion . 2019/2/19 ボイラ

BOILER WATER TREATMENT BOTTOM BLOW SURFACE BLOW BOILER WATER ANALYSIS FILTER (FEED FILTER TANK) APPLING THE CHEMICAL (Tertialy Sodium Phosphate) (Sodium Hydroxide) 2019/2/19 ボイラ

BOILER WATER ANALYSIS PH (at 25℃) 11.0~11.8 P-ALKALINITY 80 ~600 ppm M-ALKALINITY 100 ~800 ppm Cl- Max.400 PO4 3- 20~40 HARDNESS Max.1 ppm 2019/2/19 ボイラ

Necessary for BLR water Analysis and treatment ・prevention of sticking the scale When the scale stick on the tube , the place will be superheated. Finally , scale will bring the trouble(burst and crack…).Beside of that, it will be source of decreasing the thermal efficiency. ・prevention of corrosion The place where exposed with boiler water gets the corrotion with efficiency of ionize. ・prevention of carry-over Phenomenon of bringing out the boiler water with steam. It’s will be a source of decreasing the thermal efficiency and corrosion because of impurities inside the boiler water. 2019/2/19 ボイラ

SAFETY DEVICE EMERGENCY TRIP ALARM LOWEST WATER LEVEL FO LOWEST TEMPERATURE FO LOWEST PRESS IGNITION FAIL FLAME FAIL SOURCE FAIL FDF STOP EMERGENCY STOP (BOILER SIDE & C/R) ALARM LOW WATER LEVEL HIGH WATER LEVEL FO LOW TEMPERATURE FO HIGH TEMPERATURE FO LOW PRESS 2019/2/19 ボイラ

Burner Maintenance To keep a good combustion , we have a maintenance in regularly . Above all,the accumlation of the carbon around the igniter and pilot burner invite the bad ignition. When the carbon stick around the swirler,it retard the ventilation.

PERFORMANCE OF EXH.GAS ECONOMIZER HEATING SURFACE : 340 ㎡ WORKING PRESSURE : 0.59MPa STEAM TEMPERATURE : saturated FEED WATER TEMPERATURE :60℃ CAPACITY : 1000Kg/h 2019/2/19 ボイラ

BOILER WATER CIRCURATING LINE 2019/2/19 ボイラ

Heating Tube 2019/2/19 ボイラ

STEAM LINE & DUMPING SYSTEM STEAM PRESS OVER 6.8kg/c㎡ 2019/2/19 ボイラ

Dumping valve Set Press : 0.67 MPa 2019/2/19 ボイラ

Washing the heating tubes Before the washing After the washing