Network Design Issues Design and Documentation Prepared by: Aline L. Mendoza.

Slides:



Advertisements
Similar presentations
Architectural Drawing
Advertisements

7 | Means of Egress (Life Safety Code)
Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
AT&T strives to provide a smooth and successful installation experience for our Customers. We will do all that we can to install your service on time and.
Interior Wall and Ceiling Finish
Cabling system components
Chap 8 Design and Documentation
Telecommunication Rooms
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
Guide to Network Cabling Fundamentals
Residential Telecommunications Infrastructure Standard
Chapter 3: Planning a Network Upgrade
Antonio González Torres
Top-Down Network Design Chapter Three Characterizing the Existing Internetwork Copyright 2010 Cisco Press & Priscilla Oppenheimer.
Chapter 7: Intranet LAN Design
Chapter 4 – Cisco Semester I
Network Engineering Taster Day Mark Clements. 30 March 2012Engineering Taster Day 2 Welcome to Engineering Taster Day: Morning Session Ambassadors Fire.
Physical Transmission Media 8 5/9/ Modified by: Brierley.
Institute of Technology Sligo - Dept of Computing Chapter 8 Network Design and Documentation.
Cisco – Semester III Documentation. What is it most important component of a good network?  Documentation.
1 CCNA 3 v3.1 Module 5. 2 CCNA 3 Module 5 Switches/LAN Design.
Designing and Implementing Cabling Infrastructure Dr. Saif al Zahir King Fahd University of Petroleum & Minerals Computer Engineering Department Dr. Saif.
ACACIA Threaded Case Study Presented By: Louise Maguire, Caroline Kearney, Peter Honeyman, Michael Mctague.
Structured Cabling Overview
CONSTRUCTION BLUEPRINT READING
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
Installing the Network Chapter 11 Release 16/7/2009.
Cisco – Semester 1 – Chapter 9 Preview Review. Behavioral Objectives Document all work –Do it as work proceeds –Same as chapter 8 guidelines –Don’t forget.
1 Telecom Cabling Ladder racks systems and relay racks Ladder racks systems and relay racks.
Design Considerations for Telecommunications Pathways and Spaces
CSE 550 Computer Network Design Dr. Mohammed H. Sqalli COE, KFUPM Spring 2007 (Term 062)
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
1 Telecom Cabling Patch panels, cabinets and raised floors.
Chapter 17 Electrical Plans.
Cisco’s Threaded Case Study Desert View
Chap 9 Structure Cabling Project Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
The Saigon CTT Semester 1 CHAPTER 9 Le Chi Trung.
Semester 1 CHAPTER 8 Le Chi Trung
Network Design (Practical design of a network for Dowling College) by Georgi Todorov Dowling College Oakdale, NY, by.
How does AC line noise create problems?
Cisco Threaded Case Study
By H.B.O. Systems July 13, 2000 Presenters: Janet Hughes, John Banister, Karen Oliver.
HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.
1 Guide to Network Cabling Fundamentals Chapter 5.
Chapter 9 Review Structured Cabling Project. Chapter 9 Focus The focus of this chapter is standards for networking media. You read that when RJ-45 jacks.
Cabling Project. Your first responsibility, as the network designer, will be to have your client specify, in writing, the desired outcome of the project.
1 Structured media enclosure (distribution device) Structured media enclosure (distribution device) BASIC TELECOMMUNICATIONS.
Robert E. Meyers CCNA, CCAI Youngstown State University Cisco Regional Academy Instructor Cisco Networking Academy Program Semester 3, v Chapter.
Structured Cabling Hassan Alowaid Michael Chaix Reza Saputra.
Design and Documentation Chapter 8. Network Design Issues Your first step in the process is to gather information about the organization. This information.
LAN Design Semester 3, Chapter 3. Home End Table of Contents Go There! Go There! Go There! Go There! Go There! Go There! Go There! Go There! Go There!
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public 1 Version 4.1 Planning a Network Upgrade Working at a Small-to-Medium Business or ISP – Chapter.
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 1 1 Help Desk Working at a Small-to-Medium Business or ISP – Chapter 2.
TELECOMMUNICATIONS SPACES. WORK AREA WA Work Area Work Area (WA) Telecommunications Outlet (TO) Horizontal subsystem cables Equipment and patch cords.
COMMUNICATIONS AND CONTROL SYSTEMS. Interior Designer must know: Client’s priorities How space will be used Where equipment is located Location of phones,
TELECOMMUNICATIONS SPACES
Discovery 2 Internetworking Module 3 JEOPARDY K. Martin.
Sally Marable MEDT 7477 Spring Hull-Sanford Elementary School uses a client-server Ethernet network with a star topology. The Main Distribution.
1 Figure 2-6: Building Security Building Security Basics  Single point of (normal) entry to building  Fire doors, etc.: use closed-circuit television.
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 1 1 Planning a Network Upgrade Working at a Small-to-Medium Business or.
Structural cabling.
Copper-Based System Residential Cabling Topologies & Standards 8
CCNA 3 v3 JEOPARDY Module 5 CCNA3 v3 Module 5 K. Martin.
LAN Design Broadcast and Collision Domains
Structured cabling What, why & how.
Module 5 - Switches CCNA 3 version 3.0.
Horizontal and Back Bone Cabling
Architectural Drawing
Computer Systems Department.  Introduction  Course Objectives  Grading Policy  Lab Policy  Structured Cabling.
Presentation transcript:

Network Design Issues Design and Documentation Prepared by: Aline L. Mendoza

Network Design Issues Gather information about the organization Make a detailed analysis and assessment of the current and projected requirements of those people who will be using the network. Identify the resources and constraints of the organization. Documentation

Documentation that you should create as you design a network: engineering journal logical topology physical topology cut sheets problem-solving matrices labeled outlets labeled cable runs summary of outlets and cable runs summary of devices, MAC addresses, and IP addresses

Problem-solving matrices

Wiring Closet Specifications

Sizing for Wiring Closet

Wiring Closet Specification: Environmental Specification Any room, or closet that you choose to serve as a wiring closet should adhere to guidelines governing such items as the following: – materials for walls, floors, and ceilings – temperature and humidity – locations and types of lighting – power outlets – room and equipment access – cable access and support

Walls floors and ceilings MDF kPA (100 lb/ft²). IDF kPA (50 lb/ft²) If possible should be raised tiled or some other type of finished surface cm 20mm A-C plywood that is at least 2.4m high. Rooms must not have a dropped, or false, ceiling. If MDF – POP may be located inside the room. The interior wall of the POP site, behind the PBX, should be covered from floor to ceiling with 20mm plywood, with minimum of 4.6 m of wall space

Temperature and Humidity Temperature should be maintained at 21°C when all equipments are in operation Humidity should be maintained between 30%-50%. –no water or steam pipes running through or above the room, with the exception of a sprinkler system.

Lighting fixtures and power outlets if the closet serves as the MDF - minimum of two dedicated, non-switched, AC duplex electrical outlet receptacles, each on separate circuits. It should also have at least one duplex power outlet positioned every 1.8 m along each wall of the room, and should be positioned 150 mm above the floor. A wall switch, that controls the rooms main lighting, should be placed immediately inside the door. Lighting requirements for a telecommunications closet specify a minimum of 500 lx (brightness of light equal to 50 foot candles), and that light fixtures be mounted a minimum of 2.6 m above the floor.

Room and equipment access The door of a wiring closet should be at least.9 m wide, and should swing open out of the room. A wiring hub and patch panel may be mounted to a wall with a hinged wall bracket, or with a distribution rack –Hinged wall bracket - 48 cm for the panel to swing out from the wall. –Distribution rack - minimum 15.2 cm of wall clearance for the equipment, plus another cm for physical access by workmen and repairmen. A 55.9 cm floor plate, used to mount the distribution rack, will provide stability, –If the patch panel, hub and other equipment are mounted in a full equipment cabinet, they require at least 76.2 cm of clearance in front, in order for the door to swing open. Typically, such equipment cabinets are 1.8 m high x.74 m wide x.66 m deep.

Full Equipment Cabinet 1.8 m.66 m.74 m 76.2 cm

Cable access and support 10.2 cm 15.2 cm (within the wall) Any wall/ceiling openings that provide access for the conduit, or sleeved core, must be sealed with smoke and flame-retardant materials that meet all applicable codes

Identifying Potential Wiring Closets Draw a floor plan of the building to scale, and identify all of the devices that will be connected to the network. dentify secure locations that are close to the POP, that can serve as either the sole wiring closet, or as the MDF If IDFs are required. The POP is where telecommunications services, provided by the telephone company, connect to the building's communication facilities. Determining number of wiring closets Use your compass to draw circles that represent a radius of 50 m. from each of the potential hub locations. Are there any potential hub locations whose catchment areas substantially overlap? If so, you could probably eliminate one of the hub locations. Are there any potential hub locations whose catchment areas can contain all of the devices that are to be connected to the network? If so, then one of them could probably serve as the wiring closet for the entire building If you will need more than one hub in order to provide adequate coverage for all of the devices that will be connected to the network, check to see if one of them is closer to the POP than the other(s)? If so, you will probably want to select it to serve as the MDF.

Identifying Potential Wiring Closets

Identifying MDF in a Multi- Story Building

Identifying MDF in a Multi- Building Campus

Backbone cabling consists of the following: backbone cabling runs intermediate and main cross-connects mechanical terminations patch cords used for backbone-to-backbone cross-connections –vertical networking media between wiring closets on different floors –networking media between the MDF and the POP –networking media used between buildings in a multi- building campus

Networking Media for Backbone Cabling 100 UTP (four-pair) 150 STP-A (two-pair) 62.5/125 µ optical fiber single-mode optical fiber

Horizontal and Backbone Cabling (Type A) MDF IDF 3000m

Horizontal and Backbone Cabling (Type B) 2500m 500m

Horizontal and Backbone Cabling