Manual Measuring Modes of ELA 10

Slides:



Advertisements
Similar presentations
Trouble Shooting with ELQ 30 CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE Typical Cable Problems ELEKTR NIKA To learn more click on the selected topic!
Advertisements

Microprocessor and Microcontroller Based Systems Instructor: Eng.Moayed N. EL Mobaied The Islamic University of Gaza Faculty of Engineering Electrical.
Application Notes for Line Testing with ET 91 To learn more click on note! Single Sided Measurements END to END Measurements LCL Balance Impedance Return.
Chapter 5 Radio Signals & Equipment (Part 2)
Automatic xDSL Test Sequences of ELQ 30A
Application Notes for Frequency Division Multiplex System Testing with ET 91 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
ELEKTR NIKA To learn more click on the selected topic! Manual End to End Measuring Modes of ELQ 30A ► ► ► ► ► ► Loss Measurement with MTTS Group Delay.
1 SCHOOL OF COMPUTER & COMMUNICATIONS ENGINEERING EKT 341/4 ANTENNAS AND PROPAGATION Lecturer: En. Rosmizi bin Abd Rahim Dr. Mohd Faizal Bin Jamlos PLV:
Automatic Single Sided Test Sequence of ELQ 30A To learn more click on the selected topic! ELQ 30A provides single sided test sequences to estimate the.
FREQUENCY CONTROL MODES OF ET 91 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Frequency Tracking with Sweep.
Smith Chart.
Spectrum analyser basics Spectrum analyser basics 1.
3.1 Chapter 3 Data and Signals Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Harbin Institute of Technology (Weihai) 1 Chapter 2 Channel Measurement and simulation  2.1 Introduction  Experimental and simulation techniques  The.
FREQUENCY CONTROL MODES OF ET 92 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Frequency Tracking with Sweep.
King Saud University College of Applied studies and Community Service 1301CT By: Nour Alhariqi 1nalhareqi st semester
HIAPER Cloud Radar Transceiver Exciter Receiver Oscillators High-Powered Amplifier Calibration Exciter Receiver Oscillators High-Powered Amplifier Calibration.
Gates Professional Development Series Gates Sonic Tension Meter 507C NEW! Measures Tension in BothV-BeltsAnd Synchronous Belts.
SADARS An introduction to RF Spectrum Analysers With acknowledgements to Wikipedia.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
Ni.com Data Analysis: Time and Frequency Domain. ni.com Typical Data Acquisition System.
General Licensing Class G8A – G8B Signals and Emissions Your organization and dates here.
1 nd semester King Saud University College of Applied studies and Community Service 1301CT.
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
Signals and Emissions 1 G8 - SIGNALS AND EMISSIONS [2 exam questions - 2 groups] G8A - Carriers and modulation: AM; FM; single and double sideband; modulation.
Long Time Spectrogram Measurement with ET 91 The results are displayed on a 3 dimension picture ■ The time is on the vertical axis ■ The frequency is on.
Automatic Voice Frequency Test Sequences of ELQ 30A To learn more click on the selected topic! The Automatic Master-Slave Measuring mode is intended for.
Pertemuan 4 Bandwidth.
Single Ended Line Test with Upgraded ECFL 30
PLC Testing with ET 91 Level Test Set To learn more click on note! Pilot Level Measurement on RF Test Point Measurements in Special Tracking Mode Pilot.
Frequency Division Multiplex System Testing with ET 92 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise END to END Measurements.
Downstream Power Back Off (DPBO)
Manual Measuring Modes of ELA 10 To learn more click on the selected topic! Level, Loss Noise, Spectrum Line Parameter Optional Measurements Transmitting.
FREQUENCY CONTROL MODES OF ET 91 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Conventional Setting Modes.
By. Jadhav Avinash J Roll no - 2K13E11. Reference: Hewlett Packard Agilent Technology Wikipedia GwINSTEK.
FUNCTION GENERATOR.
Single Ended Measuring Modes of ELQ 30A+
Content: Distortion at electronic loads
Fletcher’s band-widening experiment (1940)
Modem Eng. M. Zamanian By Amir Taherin.
Chapter 3 ANGLE MODULATION
Manual End to End Measuring Modes of ELQ 30A+
Automatic xDSL Test Sequences of ELQ 30A+
TOPIC 3: FREQUENCY SELECTIVE CIRCUITS
Trouble Shooting with ELQ 35
pocketVNA What is a Vector Network Analyzer?
Introduction King Saud University
Amplitude Modulation.
Signal, Spectrum, and Network RF Test Equipment
Technician Licensing Class
Single Ended Line Test with Upgraded ECFL 30
Telephone & Exchange Tester ETET 30
Telephone & Exchange Tester ETET 30
Trouble Shooting with ELQ 30
Automatic Voice Frequency Test Sequences of ELQ 30A+
Downstream Power Back Off (DPBO)
Lecture 1: Communication Systems
Downstream Power Back Off (DPBO)
Single Ended Line Test with Upgraded ECFL 30
Automatic Single Sided Test Sequence of ELQ 30A+
10.5 Fourier Transform NMR Instrumentation
Manual Measuring Modes of ELA 10
Automatic Test Sequences in Master-Slave Mode
A. Linearity B. Sensitivity C. Selectivity
Automatic Test Sequences in Master-Slave Mode
Trouble Shooting with ELQ 30A+
Created by Jimmie Fouts Houston County Career Academy for
Introduction 1st semester King Saud University
Presentation transcript:

Manual Measuring Modes of ELA 10 Level, Loss Noise, Spectrum Line Parameter Optional Measurements Transmitting /Receiving Single End Loss Measurement End to End Loss Measurement Noise Measurement Spectrum Analyser Impedance Measurement Return Loss Measurement LCL Balance Measurement Echo Test Group Delay Distortion Jitter & Frequency Error Interruption Analysis Simultaneous Event Counter To learn more click on the selected topic! ELEKTR NIKA

Transmitting / Receiving ELA 10 provides two transmitting/receiving modes: ■ 1 FREQ mode (Transmitting/Receiving of one single frequency ) ■ 35 FREQ (MTTS) mode (Transmitting/Receiving of 35 frequencies simultaneously) 1 FREQ mode ■ Range: 20 Hz to 20 kHz ■ Resolution: 1 Hz 35 FREQ (MTTS) mode ■ Range: 200 to 3600 Hz ■ Step: 100 Hz ELEKTR NIKA

Single End NEXT / LOSS Measurement ELA 10 provides three single-end loss measuring modes: ■ Measurement with one single frequency ■ Measurement with 35 frequencies at the same time (200 to 3600 Hz) ■ Measurement in sweep mode (200 Hz to 9 kHz) Option ELEKTR NIKA

END to END Loss Measurement with (MTTS) ELA 10 in MTTS transmitting and receiving modes provides: ■ Transmitting 35 frequencies at the same time ■ Receiving 35 frequencies at the same time Frequency range: 200 to 3600 Hz, frequency step: 100 Hz The advantages of MTTS : ■ Quick and comfortable ■ No synchronization is necessary between transmitter and far end receiver ELA 10 in 35 FREQ transmitting mode ELA 10 in 35 FREQ receiving mode ELEKTR NIKA

Noise Measurement ELEKTR NIKA ELA 10 provides : ■ Noise measurement with selectable weighting filters ■ Noise measurement with Psophometer filter and 1020 conditioning tone ■ 1020 Hz conditioning tone generation ELEKTR NIKA

Selectable Evaluation Modes Spectrum Analyser Spectrum analyser of ELA 10 is intended to: ■ analyse the in-band and out-band noises ■ analyse the level of distortion products Selectable Ranges Selectable Evaluation Modes Frequency range Bandwidth Zoom OFF Zoom ON 20 to 360 Hz 2 Hz 1 Hz 0.2 to 3.6 kHz 20 Hz 10 Hz 0.2 to 20 kHz 100 Hz 50 Hz 0.5 to 85 kHz 500 Hz 200 Hz NORMAL AVG PEEK ELEKTR NIKA

Impedance Measurements ELA 10 provides three impedance measuring modes: ■ Measurement with one single frequency (200 Hz to 10 kHz) ■ Measurement with 35 frequencies at the same time (200 to 3600 Hz) ■ Measurement in sweep mode (200 Hz to 9 kHz) Option ELEKTR NIKA

Return Loss Measurement Return loss factor indicates the deviation of line impedance from the nominal value. ELA 10 performs a bridge measurement comparing the line impedance to an internal Rn normal resistor. Three return loss measuring modes are provided: ■ Measurement with one single frequency (200 Hz to 10 kHz) ■ Measurement with 35 frequencies at the same time (200 to 3600 Hz) ■ Measurement in sweep mode (200 Hz to 9 kHz) Option ELEKTR NIKA

Balance (LCL) Measurement ELA 10 provides LCL measurement using the test circuit described in ITU-T Rec. 0.9 Tested line Three balance measuring modes are provided: ■ Measurement with one single frequency (200 Hz to 10 kHz) ■ Measurement with 35 frequencies at the same time (200 to 3600 Hz) ■ Measurement in sweep mode (200 Hz to 9 kHz) Option ELEKTR NIKA

Echo Test There are several reasons for the undesirable quality degradation and the appearance of audible echoes is one of them. This kind of quality degradation is inherent in the network equipment and the end user phone devices. For the test of the disturbing echoes ELA 10 transmits short ~1020 Hz signal packets with proper amplitude shaping and measures the amplitude and the traveling time of the reflected signal. Time [s] Measuring ranges ■ Traveling time range: 15 to 2500 ms ■ Time resolution: 5 ms ■ Amplitude indication: down to -60 dBm ELEKTR NIKA

Group Delay Distortion Measurement The group delay distortion measurement needs two ELA 10 instruments connected to the ends of the tested pair. One of them transmits a test tone the other one receives and evaluates it. ELA 10 applies: The multi tone test (MTTS) method described in the recommendation ITU-T O.81 Appendix I. ELA 10 performs Group delay distortion and level measurements simultaneously. ELEKTR NIKA

Phase Jitter & Frequency Error Measurement The jitter and frequency error measurement needs two ELA 10 instruments connected to the ends of the tested pair. One of them transmits a jitter free quartz accurate 1020 Hz test tone the other one receives and evaluates it. ELA 10 performs the two measurements simultaneously according to rec. ITU-T O.91 ELEKTR NIKA

Interruption Analysis The interruption analysis needs two ELA 10 instruments connected to the ends of the tested pair. One of them transmits 1020 Hz test tone the other one receives it and detects the micro interruptions according to rec. ITU-T O.62. An interruption is detected when the level of the received test tone drops below a designated threshold for more than 0.6 ms. Short form information Histogram The measuring time is adjustable between 5 min and 72 hours. List ELEKTR NIKA

Simultaneous Event Counter The event test needs two ELA 10 instruments connected to the ends of the tested pair. One of them transmits a test tone the other one receives it and simultaneously counts the number of events like: ■ Amplitude hits (described in rec. ITU-T O.95) ■ Phase hits (described in rec. ITU-T O.95) ■ Interruptions (described in rec. ITU-T O.61) ■ Noise impulses (described in rec. ITU-T O.71) Measuring times: 5, 15, 30, 60 min Maximum count: 65000 for each counter ELEKTR NIKA

THANK YOU FOR YOUR ATTENTION!