Denver Fire Alarm Test Preparation Speed Drill © Ted Smitty Smith 2013.

Slides:



Advertisements
Similar presentations
Title Subtitle.
Advertisements

Multiplying binomials You will have 20 seconds to answer each of the following multiplication problems. If you get hung up, go to the next problem when.
7 | Means of Egress (Life Safety Code)
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Denver Fire Alarm Test Prep
NFPA 72 - National Fire Alarm Code Chapter 4 - Notification Appliances
ECCODES A Leader in Education Are You smarter than a THIRD Year Apprentice? Electricians.
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
We will resume in: 25 Minutes.
LOUISIANA DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS
NFPA National Fire Alarm & Signaling Code
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
WELCOME DBI & SFFD Meet the Pros October 11, 2007.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
2014 CHANGES TWO MINUTE DRILL COPYRIGHT TED “SMITTY” SMITH ©2014.
©Ted “Smitty” Smith This speed drill focuses on calculations that will be required for the journeyman and masters examination. The question slide.
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
Copyright 2005 Ted "Smitty" Smith Two Minute Drill Number Three Improving your skill in code Look Up Increasing Speed Drill.
Two Minute Drill #10 Copyright 2005 Ted "Smitty" Smith.
Calculation Speed Drill # NEC
Smitty’s Speed Drills 2008 Code Drills Health Care Facilities (C) Copyright 2008 Ted "Smitty" Smith1.
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
©Ted “Smitty” Smith This speed drill focuses on subjects that will be required for the journeyman and masters examination arranged by chapter of.
Two Minute Drill Number 23- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Two Minute Drill Number 31- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Two Minute Drill Number 22- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
2008 Code Drills (C) Copyright 2008 Ted "Smitty" Smith 1 Smitty’s Speed Drills.
Copyright 2008 Ted "Smitty" Smith Two Minute Drill Number 21- Residential Improving your skill in code Look Up Increasing Speed Drill.
Class A, B, and now N NFPA 72, 2016 Edition Dan Horon President
Smitty’s Two Minute Drill Grounding
Carbon Monoxide Detection: Code and Legislation Updates
Smitty’s Two Minute Drill Grounding
2011 Changes Two Minute Drill
Smitty’s Two Minute Drills
Proposed Changes to the 2009 International Building & Fire Codes
NICET Fire Alarm Tech Level 1 Practice Test
NICET Fire Alarm Tech Level 1 Practice Test # 4
Fire Alarm Systems for Emergency Operations of Elevators
NICET Fire Alarm Tech Level 1 Practice Test # 6
Smitty’s Two Minute Drill Mixed Content -05
NICET Fire Alarm Tech Level 1 Practice Test # 13
NICET Fire Alarm Tech Level 1 Practice Test # 2
NICET Fire Alarm Tech Level 1 Practice Test # 3
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Calculations: Transformers and Service Conductor Calculations
Smitty’s Super Speed Drill for Memorization No
NICET Fire Alarm Tech Level 1 Practice Test # 10
Smitty’s Two Minute Drill #1: Feeders and Branch Circuits
Smitty’s Two Minute Drill Photovoltaic Systems
Two Minute Drill Number 29- Conductors and Raceways
Fire Alarm Tech Practice Test # 16 NICET
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Smitty’s Two Minute Drill Grounding and Bonding
2008 Code Drills Health Care Facilities
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Smitty’s Two Minute Drill Services, Feeders, and Branch Circuits 1
Load Calculation Speed Drill
Two Minute Drill – Residential 3
Smitty’s Two Minute Drill Varied Number 7
FIRE ALARM DRILL 26 © Ted Smith 2017.
Smitty’s Two Minute Drill General Knowledge
Smitty’s Two Minute Drill The BIG 5 Drill 1
Smitty’s Two Minute Drill General Knowledge 2
Denver Fire Depart. License Fire Alarm Practice Test # 12
Presentation transcript:

Denver Fire Alarm Test Preparation Speed Drill © Ted Smitty Smith 2013

Instructions This drill is designed to help you practice finding things in the National Fire Alarm and Signaling Code 2010 version. In order to receive the maximum benefit put the power point presention into presentation mode by clicking on the icon of projector screen in the lower right hand corner. When you are ready to begin, click on the slide and the timed drill will begin. Each question will remain in the screen for 2 minutes and then transition to the next question. Do not worry if you dont find the answer, just keep trying your best until the timed portion is complete. When the timed potion is complete a STOP sign will appear. Click on the slide again and the questions will be presented again without the timer and the answers will also be on the slides along with the code reference. The purpose of the drills is to help you get to the point that you can find the correct answer to our question in under 2 minutes. CLICK ON THE SLIDE TO CONTINUE

1.Which of the following statements are true concerning an electrical circuit that is the primary power supply for a fire alarm system? a)The location of the branch circuit disconnect must be permanently identified at the disconnecting location b)The disconnecting means shall be identified as Fire Alarm Control Panel Power Source c)The disconnecting means shall have a red marking or be clearly labeled using black letters on a white background d)The disconnecting means shall be accessible to any qualified personnel.

2. In the absence of specific performance based design criteria, smooth ceiling smoke detector spacing shall be a nominal ________ feet. a)10 b)15 c)20 d)30

3. The lead acid batteries in a central station facility shall be charger tested at initial installation and then _______________. a)Weekly b)Monthly c)Quarterly d)Annually

4. An average ambient sound level greater than ____________dBA shall require the use of a visible notification appliance. a. 90 b. 105 c. 115 d. 120

5. The secondary power supply of a fire alarm system shall have sufficient capacity to operate the system under quiescent load for a minimum of 24 hours and at the end of that period, shall be capable of operating all alarm notification appliances used for evacuation or to direct aid to the location of an emergency for ________ minutes. A.30 B.10 C.5 D.1

6. All fire alarm system shall test free of ______________. a. failures b. grounds c. surges d. faults

7. Which of the following areas are not required to have an approved single or multiple station smoke alarm installed in single family dwellings a. In all sleeping rooms and guest rooms b. On the floor loft that is only a recreation room c. In the basement d. In the garage

8. Which of the following statements are not true concerning monitoring for integrity? A. It is not required for central station circuits serving notification appliances within a central station B. It is not required for a trouble circuit C. It is not required for notification appliances D. It is not required for shorts between conductors

9. A fire alarm systems smoke detectors must be tested for functionality at the initial installation and then again ____________? A. Monthly B. Quarterly C. Annually D. Not required after initial test

10. A _______________ is any circuit, conductor, optic fiber, radio carrier, or other means connecting two or more locations. A. Circuit B. Path or Pathway C. Raceway D. None of the above

11. Activation of the initiating device for a sprinkler waterflow shall occur within ________ seconds of waterflow at the alarm initiating device when flow occurs that is equal to or greater than that from a single sprinkler of the smallest orifice size installed in the system. A. 10 B. 30 C. 60 D. 90

12. Actuation of alarm notification appliances for emergency voice communications, fire safety functions, and annunciation at the protected premises shall occur within ______ seconds after the activation of an initiating device. A. 10 B. 30 C. 60 D. 90

13. Which of the following is not a performance requirement of a Class A pathway? A. It includes a redundant path B. Operational capability continues past a single open C. Conditions that affect the intended operation of the path are annuciated D. A loss of end to end communication is annuciated

14. For sloping ceilings with beams running parallel up slope, spot type detectors shall be located _____________________________? A. at the bottom of the beams B. on the ceiling within beam pockets C. spaced not less than 25% of the rating D. with detector at the top of slope only

15. The number of waterflow alarm initiating devices permitted to be connected to a single initiating device circuit shall not exceed ______. A. 1 B. 3 C. 5 D. 7

A Which of the following statements are true concerning an electrical circuit that is the primary power supply for a fire alarm system? a)The location of the branch circuit disconnect must be permanently identified at the disconnecting location b)The disconnecting means shall be identified as Fire Alarm Control Panel Power Source c)The disconnecting means shall have a red marking or be clearly labeled using black letters on a white background d)The disconnecting means shall be accessible to any qualified personnel.

C In the absence of specific performance based design criteria, smooth ceiling smoke detector spacing shall be a nominal ________ feet. a)10 b)15 c)20 d)30

D The lead acid batteries in a central station facility shall be charger tested at initial installation and then _______________. a)Weekly b)Monthly c)Quarterly d)Annually

B An average ambient sound level greater than ____________dBA shall require the use of a visible notification appliance. a. 90 b. 105 c. 115 d. 120

D. T The secondary power supply of a fire alarm system shall have sufficient capacity to operate the system under quiescent load for a minimum of 24 hours and at the end of that period, shall be capable of operating all alarm notification appliances used for evacuation or to direct aid to the location of an emergency for ________ minutes. A.30 B.10 C.5 D.1

B All fire alarm system shall test free of ______________. a. failures b. grounds c. surges d. faults

D Which of the following areas are not required to have an approved single or multiple station smoke alarm installed in single family dwellings a. In all sleeping rooms and guest rooms b. On the floor loft that is only a recreation room c. In the basement d. In the garage

C Which of the following statements are not true concerning monitoring for integrity? A. It is not required for central station circuits serving notification appliances within a central station B. It is not required for a trouble circuit C. It is not required for notification appliances D. It is not required for shorts between conductors

C T A fire alarm systems smoke detectors must be tested for functionality at the initial installation and then again ____________? A. Monthly B. Quarterly C. Annually D. Not required after initial test

B A _______________ is any circuit, conductor, optic fiber, radio carrier, or other means connecting two or more locations. A. Circuit B. Path or Pathway C. Raceway D. None of the above

D Activation of the initiating device for a sprinkler waterflow shall occur within ________ seconds of waterflow at the alarm initiating device when flow occurs that is equal to or greater than that from a single sprinkler of the smallest orifice size installed in the system. A. 10 B. 30 C. 60 D. 90

A Actuation of alarm notification appliances for emergency voice communications, fire safety functions, and annunciation at the protected premises shall occur within ______ seconds after the activation of an initiating device. A. 10 B. 30 C. 60 D. 90

D Which of the following is not a performance requirement of a Class A pathway? A. It includes a redundant path B. Operational capability continues past a single open C. Conditions that affect the intended operation of the path are annuciated D. A loss of end to end communication is annuciated

B For sloping ceilings with beams running parallel up slope, spot type detectors shall be located _____________________________? A. at the bottom of the beams B. on the ceiling within beam pockets C. spaced not less than 25% of the rating D. with detector at the top of slope only

C The number of waterflow alarm initiating devices permitted to be connected to a single initiating device circuit shall not exceed ______. A. 1 B. 3 C. 5 D. 7