2007-08-20(copyright) Simmons akustik & utveckling ab 20071 Calculate sound insulation according to national codes and guidelines (e.g. BBR) and EN 12354.

Slides:



Advertisements
Similar presentations
PowerPoint Tutorial 1 Creating a Presentation
Advertisements

Word Tutorial 2 Editing and Formatting a Document
Excel Tutorial 3 Working with Formulas and Functions
Objectives Create an action query to create a table
Noise Control & Room Modes
January 23, Quincy Wu Interconnecting VoIP on Taiwan Academic Network (TANet)
GL9 Antwerpen - 11 December Open access to full text and ETDs in Europe: improving accessibility through the choice of language? Christiane Stock.
TeraGrid's GRAM Auditing & Accounting, & its Integration with the LEAD Science Gateway Stuart Martin Computation Institute, University of Chicago & Argonne.
Scaling distributed search for diagnostics and prognostics applications Prof. Jim Austin Computer Science, University of York UK CEO Cybula Ltd.
ANNEX B Mini Tutorial for Using the Department of Human Services’ (DHS) Electronic Budget Form.
3 october Brown easyBorrow (beta) Brown University Library October 2007.
Word Tutorial 1 Creating a Document
Contents: Cover
National Database Templates for the Biosafety Clearing-House Application (NDT-nBCH) Overview of the US nBCH Applications.
RCM-Tool v1.0 Demo Performing Welcome to the RCM-Tool RCM-Tool
V3.0 12/04/ For Coral Systems With PRI Services Presented by Education Technology Services.
CS-Strumentazione Elettronica About Us Based in Milan(Italy), CS Strumentazione Elettronica was founded in 1971 to assist our customers with.
ADBIS A Method for Comparing Self- Organizing Maps: Case Studies of Banking and Linguistic Data Toomas Kirt, Ene Vainik, Leo Võhandu.
Elliott / October Understanding the Construct to be Assessed Stephen N. Elliott, PhD Learning Science Institute & Dept. of Special Education Vanderbilt.
Italian white certificates scheme
Objectives Explore a structured range of data Freeze rows and columns
Access 2007 ® Use Databases How can Microsoft Access 2007 help you structure your database?
Integrating people, process and technology! Social Media Specialist Making a Difference in Business.
Word Tutorial 5 Working with Templates and Outlines
You can use this presentation to: Gain an overall understanding of the purpose of the revised tool Learn about the changes that have been made Find advice.
InJoy&Train FAFB Information Day 16 November, 2007 SMEs in FP7 Tigran Arzumanyan.
Sound insulation materials and constructions Tsvetan Nedkov, Ivaylo Hristev UACG 2014 г.
10 February Doors TM for Windows TM Software Installation.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
© Janice Regan, CMPT 102, Sept CMPT 102 Introduction to Scientific Computer Programming The software development method algorithms.
XP New Perspectives on Microsoft Office Excel 2003, Second Edition- Tutorial 6 1 Microsoft Office Excel 2003 Tutorial 6 – Working With Multiple Worksheets.
PowerPoint: Tables Computer Information Technology Section 5-11 Some text and examples used with permission from: Note: We are.
Homepage To learn about eLOMA click on the ‘Learn about eLOMA’ link under the Tools For Professionals.
Online testing made effective and easy. The easy way to have your tests answered and scored online. If you have a test in a PDF file, it can be online.
Section 13.1 Add a hit counter to a Web page Identify the limitations of hit counters Describe the information gathered by tracking systems Create a guest.
SEEA Presentation to SEES March 2006 SEEA Presentation to SEES February 2006 SOUTHEAST ENERGY EFFICIENCY ALLIANCE.
Using Dreamweaver. Slide 1 Dreamweaver has 2 screens that do different things The Document window where you create your WebPages The Site window where.
Nancy Severe-Barnett Program Coordinator, SCIS
Physical Database Design Chapter 6. Physical Design and implementation 1.Translate global logical data model for target DBMS  1.1Design base relations.
Activating Clarity  Activating Clarity  Activation  Online Activation  Fax Activation  Review and Verify Activation and License Terms  Updating.
Office Management Tools II Ms Saima Gul. Office Management Tools II Ms Saima Gul.
0 Load Calculation Manual Output : 1. Screen Outputs (Results, Pareto Chart, Hourly Estimation) 2. Optional Outputs (*CLTD.txt, *TETD.txt) 3.
Heat Treatment Calculator (H.T.C) Sham Kashyap Computing and Information Sciences Kansas State University.
Access 2007 ® Use Databases How can Microsoft Access 2007 help you structure your database?
SIMO SIMulation and Optimization ”New generation forest planning system” Antti Mäkinen & Jussi Rasinmäki Dept. of Forest Resource Management.
Group 4B: Bergold, Kajander, Leppä, Niemeläinen, Pesonen.
Software Engineering1  Verification: The software should conform to its specification  Validation: The software should do what the user really requires.
United Nations Oslo City Group on Energy Statistics OG7, Helsinki, Finland October 2012 ESCM Chapter 8: Data Quality and Meta Data 1.
Technology in Architecture
Moodle Quizes Staff Guide. Creating Quizzes Click Add an Activity or Resource With the course in editing mode...
1 Project 2: Using Variables and Expressions. 222 Project 2 Overview For this project you will work with three programs Circle Paint Ideal_Weight What.
Microsoft Office 2013 Try It! Chapter 4 Storing Data in Access.
Publications Coordinators – Create and Verify a Publication.
Robustdetails Feedback from Robust Details Technical Advisors.
Contact Contact Teacher Training Service Tracking.
Component D: Activity D.3: Surveys Department EU Twinning Project.
To play, start slide show and click on circle Access 1 Access 2 Access 3 Access 4 Access Access
Department of building structures, Czech Technical University, Ing. Jaroslav Hejl, Ing. Jiří Nováček, Ph.D. sound insulation.
Refer to slide robustdetails robustdetails.
ACOUSTICS Aural Comfort & Noise.
Sustainable new homes and sound insulation 2006
Regulation and compliance with performance standards
ACOUSTIC DESIGN OF BUILDINGS
Applied Acoustics Dan Int-Hout, Chief Engineer, Krueger
Exploring Microsoft® Access® 2016 Series Editor Mary Anne Poatsy
James Blankenship March , 2018
SOUND INSULATION.
(copyright) Simmons akustik & utveckling ab 2018
BCAR & The Technical Guidance Documents Conference 2019 Part E: Sound
Presentation transcript:

(copyright) Simmons akustik & utveckling ab Calculate sound insulation according to national codes and guidelines (e.g. BBR) and EN (ISO 15712) using BASTIAN ® and the built-in databases Examples given on how to verify airborne and impact sound insulation of walls and floors traffic noise insulation of facades, windows and air inlets

(copyright) Simmons akustik & utveckling ab Presentations 1.BASTIAN examples horisontal insulation from impact and airborne sound vertical insulation from impact and airborne sound facade insulation from traffic noise 2.Input data, how are the databases constructed ? 3.Can one rely on calculation results ? 4.Background to BASTIAN, the standard EN 12354

(copyright) Simmons akustik & utveckling ab Screen in BASTIAN at startup: 1.Calculate horisontal, vertical or facade insulation? Choose! 2. Room dimensions, click & type !

(copyright) Simmons akustik & utveckling ab First, choose how walls and floors are attached to each other (types of junction): 3. Double click and choose junction !

(copyright) Simmons akustik & utveckling ab Choose walls and floors from the database: 4. D-click and choose building element ! 5. Receiving room data are copied from the source room, may be changed

(copyright) Simmons akustik & utveckling ab Choose floorings, linings or suspended ceilings: 6. D-click and choose !

(copyright) Simmons akustik & utveckling ab Ready – read of the weighted results: Rw (weighted sound reduction index) L n,w or L nT,w (impact sound) Look at frequency curves of direct sound path and flanking paths, with %- contribution per path Look at all kinds of weighted values, with spectrum adaption terms listed 7. Read of results !

(copyright) Simmons akustik & utveckling ab Vertical sound insulation Calculate large rooms – often leading for airborne sound. Add small rooms with several heavy walls, often leading for impact sound Scrutinize designed junctions, choose appropriate models Combine different slabs, cast screeds and floorings that comply with the requirements –It may be more efficient to change the screed or slab profile or number of heavy walls than to add a floating floor, or the opposite…! Keep trying, in a few minutes you have tested a variety of constructions that comply with the requirements. Keep an eye on the main transmission paths, improve on the main sound leakages before changing the other constructions.

(copyright) Simmons akustik & utveckling ab 20079

(copyright) Simmons akustik & utveckling ab Calculate sound indoors from traffic etc Choose outer wall, window, door and air inlet Choose among a variety of airborne sound sources. Type spectrum for vehicles given according to SS25267 annex D and the Nordic traffic noise calc. model NORD2005 Look at partial transmission (%) for each window, air inlet and wall, as well as outdoor and indoor sound levels. Calculations are made in third octave bands, giving an optimal choice of product. Forget about the C-terms, this handles it all and gives you the A-levels!

(copyright) Simmons akustik & utveckling ab Listen to the traffic sounds as being indoors yourself The computer attenuates the original sound outdoors according to the calculated sound reductions, in each third octave band, and adds room reverberation. To achieve a correct listening impression, auralization must be made at a realistic level just above the background noise of the room where the demonstration is made. Choose type of sound source Choose relevant Worksheet (wall, window etc) Choose type of listening room indoors Use A/B-test of 2 worksheets, e.g. to compare subjective effects of changing windows

(copyright) Simmons akustik & utveckling ab Manufacturers may now easily advertise their products in our databases, on the basis of well documented tests or theoretical investigations. How the BASTIAN- databases are constructed The databases are distributed quarterly to users in Sweden, Norway, Denmark, Finland and Island, with updates and new products In cooperation with DB Akustik and SINTEF Byggforsk Sound insulation for a large number of old, generic constructions have been added with support from the Swedish research fund SBUF (project 11254)

(copyright) Simmons akustik & utveckling ab Step 1 – Advertisement & product data The manufacturer: 1.Choose products to advertise in the databases, optionally with support from an acoustic consultant or a laboratory 2.Determine product name designations (names, numbers etc.) 3.Send data for each product, as test protocols or theoretical investigations, showing airborne and/or impact sound insulation (-or improvements). We apply some miniumum requirements on the documentation of the sound properties of the products, cf. /advertise. 4.Attach a picture file of the product (550x550 pxl, 256 colours) 5.Add a short information (1-2 rows) on the product, web-link to product sheets or similar for extended information to users Send all data for audit and input to the database files New database files are distributed quarterly to >100 users across all Nordic countries. We, DB Akustik and SINTEF Byggforsk coordinates the distribution of database files – one input is enough.

(copyright) Simmons akustik & utveckling ab Step 2 – input to the databases These data are entered: –Category/Product type –Product designation –Picture file name (.JPG) –Sound reduction data, dB –Norm. impact levels, dB –Surface weight, kg/m 2 –Coincidence freq. f c, Hz –Thickness, m Manufacturers are responsible for their data (we review them) In case errors are discovered, updates are distributed without additional costs All database versions are stored

(copyright) Simmons akustik & utveckling ab Step 3 – appearance in database chooser This is how the product may appear when the users opens the chooser tool: The databases have products from many countries. A filter facilitates use. Generic constructions added to facilitate calculations of old houses, from SAU (us), Nordtest, SBUF, NBI or other open publications.

(copyright) Simmons akustik & utveckling ab Step 4 – how calculations are made The users double click on the tables or the picture. Selectable constructions are then presented to the user BASTIAN then calculates sound insulation and sound levels with respect to spectrum of the sound source and level, construction areas, flanking transmission and the inter- action between the constructions The manufacturers do not any longer have to present expected (realistic) sound class in the building using their products, since this is always related to the inter-action with the surrounding constructions. Now, the software takes these precautions. All calculations made according to SS-EN 12354, SS 25267/-68 and the building codes

(copyright) Simmons akustik & utveckling ab Are the calculated results reliable? Comparisons with >100 field measurements advice: - keep at least 1 dB margin to req. in SS 25267/-68 - keep at least 3 dB marginal to older req, and 4-5 dB for light floors (depends on type of supporting structures) Use only products with well documented input data Quality of products and construction are critical – errors and defects are not accounted for in these margins Read more at section Akustikhandboken and Akustikguidenwww.byggamedprefab.se Look at our FAQ, common questions and answers at

(copyright) Simmons akustik & utveckling ab BASTIAN version – more functions, easier to use implements the EN standards (parts 1-3), which have revolutionized the building acoustic planning work for consultants new models for heavy double walls, e.g. sandwich or brick walls complies with building regulations (e.g. BBR) databases contain qualified products that fulfils requirements in the building, which facilitates changes to technically equal alternatives. This encourages competition among builders, products and systems enables estimates of direct sound and flanking transmission, taking all building parts into account Weighted numbers do not tell all the truth…Use auralization – listen how it sounds in real life, inside the house! Now with network access and databases from several countries Bastian Bastian ® :

(copyright) Simmons akustik & utveckling ab EN-standarder in the BBR regulations Building acoustics - Estimation of acoustic performance of buildings from the performance of elements –Part 1: Airborne sound insulation between rooms –Part 2: Impact sound insulation between rooms –Part 3: Airborne sound insulation against outdoor sound Input data are laboratory values or field data of building elements, determined according to ISO standardised methods, or by theoretical investigations. We examine all input data prior to publishing. The calculation model utilizes well known statistical models, similar to heat conduction models. These models are uncertain in the individual case, particularly at low frequency. The precision is still acceptable, which is continously investigated by comparison to field measurements. Calculation results are the same weighted numbers as stated in the Swedish requirements BBR / SS /-68 (R´ w, L´ n,w, C x -terms)

(copyright) Simmons akustik & utveckling ab More information About BASTIAN and the databases – Download software demo: – Read papers (some in Swedish, some in English): – link to Böcker&Artiklarwww.simmons.se Contact: (20)