The congenitally bicuspid aortic valve: how does it function

Slides:



Advertisements
Similar presentations
PERMANENT PREMOLARS Succeed deciduous molars 8 in all Max 1 st 2 nd & Mand 1 st – from 4 lobes Mand 2 nd – from 5 lobes one large buccal cusp Mand present.
Advertisements

Functional Collagen Fiber Architecture of the Pulmonary Heart Valve Cusp  Erinn M. Joyce, BS, Jun Liao, PhD, Frederick J. Schoen, MD, PhD, John E. Mayer,
Aortic Root Biomechanics After Sleeve and David Sparing Techniques: A Finite Element Analysis  Giordano Tasca, MD, Matteo Selmi, MS, Emiliano Votta, PhD,
Modeling leaflet correction techniques in aortic valve repair: A finite element study  Michel R. Labrosse, Munir Boodhwani, Benjamin Sohmer, Carsten J.
Simulated elliptical bioprosthetic valve deformation: Implications for asymmetric transcatheter valve deployment  Wei Sun, Kewei Li, Eric Sirois  Journal.
Late Surgical Explantation and Aortic Valve Replacement After Transcatheter Aortic Valve Implantation  Louis W. Wang, MBBS, MM, Emily K. Granger, MBBS,
Biomechanical implications of the congenital bicuspid aortic valve: A finite element study of aortic root function from in vivo data  Carlo A. Conti,
Date of download: 12/19/2017 Copyright © ASME. All rights reserved.
Hans-H. Sievers, MD, Claudia Schmidtke, MD, MBA 
The left ventricular outflow tract in atrioventricular septal defect revisited: Surgical considerations regarding preservation of aortic valve integrity.
Aortic Valve Reconstruction With Leaflet Replacement and Sinotubular Junction Fixation: Early and Midterm Results  Meong Gun Song, MD, Hyun Suk Yang,
Segmental Approach to Repair of Regurgitant Bicuspid Aortic Valves
Surgical Correction of Congenital Supravalvular Aortic Stenosis
Computer modeling for the prediction of thoracic aortic stent graft collapse  Salvatore Pasta, PhD, Jae-Sung Cho, MD, Onur Dur, PhD, Kerem Pekkan, PhD,
Aortic Root Biomechanics After Sleeve and David Sparing Techniques: A Finite Element Analysis  Giordano Tasca, MD, Matteo Selmi, MS, Emiliano Votta, PhD,
Biomechanics of Failed Pulmonary Autografts Compared to Native Aortic Roots  Aart Mookhoek, MD, Kapil Krishnan, PhD, Sam Chitsaz, MD, PhD, Heide Kuang,
Bicuspid aortic valves undergo excessive strain during opening: A simulation study  Susumu Katayama, MSc, Nobuyuki Umetani, MEnv, Toshiaki Hisada, PhD,
Aortic Valve Repair  Delos M. Cosgrove, Charles D. Fraser 
Opening and closing characteristics of the aortic valve after valve-sparing procedures using a new aortic root conduit  Ruggero De Paulis, MD, Giovanni.
Surgical and Pathological Anatomy of the Aortic Valve and Root
Orientation of tilting disc and bileaflet aortic valve substitutes for optimal hemodynamics  Joachim Laas, MD, Peter Kleine, MD, Michael J Hasenkam, MD,
Three-dimensional echocardiography improves the understanding of left atrioventricular valve morphology and function in atrioventricular septal defects.
Timothy M. Colen, MBBS, Nee S. Khoo, MBChB, David B
Functional Collagen Fiber Architecture of the Pulmonary Heart Valve Cusp  Erinn M. Joyce, BS, Jun Liao, PhD, Frederick J. Schoen, MD, PhD, John E. Mayer,
A new technique for debridement in rheumatic valvular disease: the rasping procedure  Nobuo Kitamura, MD, Shinichi Uemura, MD, Ryuji Kunitomo, MD, Junichi.
Heart Booster: a pericardial support device
Cause of degenerative disease of the trileaflet aortic valve: review of subject and presentation of a new theory  Francis Robicsek, MD, PhD, Mano J Thubrikar,
A total of 404 cases of aortic valve reconstruction with glutaraldehyde-treated autologous pericardium  Shigeyuki Ozaki, MD, PhD, Isamu Kawase, MD, Hiromasa.
In-Vivo Dynamic Deformation of the Mitral Valve Anterior Leaflet
Methods for graft size selection in aortic valve-sparing operations
Remodeling the Aortic Root and Preservation of the Native Aortic Valve
Tubular heart valves: A new tissue prosthesis design—Preclinical evaluation of the 3F aortic bioprosthesis  James L. Cox, MD, Niv Ad, MD, Keith Myers,
Morphologic and Functional Markers of Aortopathy in Patients With Bicuspid Aortic Valve Insufficiency Versus Stenosis  Evaldas Girdauskas, MD, PhD, Mina.
Restricted cusp motion in right-left type of bicuspid aortic valves: A new risk marker for aortopathy  Alessandro Della Corte, MD, PhD, Ciro Bancone,
An intraoperative test device for aortic valve repair
G. Chad Hughes, MD, Madhav Swaminathan, MD, Walter G. Wolfe, MD 
Mano J. Thubrikar, PhD, Francis Robicsek, MD, Brett L. Fowler, BS 
Measurement of Mitral Leaflet and Annular Geometry and Stress After Repair of Posterior Leaflet Prolapse: Virtual Repair Using a Patient-Specific Finite.
Aortic root morphology in patients undergoing percutaneous aortic valve replacement: Evidence of aortic root remodeling  Mateen Akhtar, MD, E. Murat Tuzcu,
Mechanical properties of myxomatous mitral valves
An unusual combination of cardiovascular surgical disorders
Roxane McKay, MD, FRCS, FRCSCa, Robert H. Anderson, BSc, MD, FRCPathb
Results of Aortic Valve-Sparing and Restoration With Autologous Pericardial Leaflet Extensions in Congenital Heart Disease  Jonah Odim, MD, PhD, MBA,
Cusp height in aortic valves
Aortic stenosis of the neonate: A single-center experience
The Ross Procedure in Adults: Long-Term Follow-Up and Echocardiographic Changes Leading to Pulmonary Autograft Reoperation  Alessandro Frigiola, MD, Marco.
Mathieu Vergnat, MD, Melissa M. Levack, MD, Benjamin M
Aortic replacement for bicuspid aortic valve aortopathy: When and why?
Hans-H. Sievers, MD, Claudia Schmidtke, MD, MBA 
Bicuspidization of the Unicuspid Aortic Valve: A New Reconstructive Approach  Hans-Joachim Schäfers, MD, Diana Aicher, MD, Svetlana Riodionycheva, MD,
The Journal of Thoracic and Cardiovascular Surgery
Konno procedure for infective endocarditis involving aortic valve in a small child  Kazutomo Goh, MD, Hiroshi Yamamoto, MD, Naoya Tsuda, MD, Tadahiro Sasajima,
Johnson Hua, BS, William R. Mower, MD, PhD  Journal of Vascular Surgery 
Dynamic analysis of the aortic valve using a finite element model
Sixty Years After Tetralogy of Fallot Correction
Biomechanical implications of the congenital bicuspid aortic valve: A finite element study of aortic root function from in vivo data  Carlo A. Conti,
A novel method for reconstructing the sinus and annulus for the treatment of annuloaortic ectasia  Takeshi Shimamoto, MD, Akira Marui, MD, PhD, Takeshi.
Andrew Gogbashian, MD, Ravi K
Mechanisms of aortic valve incompetence: finite element modeling of aortic root dilatation  K.Jane Grande, PhD, Richard P Cochran, MD, Per G Reinhall,
Aortic root numeric model: Annulus diameter prediction of effective height and coaptation in post–aortic valve repair  Gil Marom, MSc, Rami Haj-Ali, PhD,
David J. Kaczorowski, MD, Y. Joseph Woo, MD 
Wobbe Bouma, MD, Chikashi Aoki, MD, Mathieu Vergnat, MD, Alison M
Paul Urbanski, MD, PhD  The Annals of Thoracic Surgery 
Preservation of the Bicuspid Aortic Valve
Severe aortic regurgitation immediately after mitral valve annuloplasty  Anique Ducharme, MD, Jean-François Courval, MD, Annie Dore, MD, Yves Leclerc,
Mathieu Vergnat, MD, Arminder S. Jassar, MBBS, Benjamin M
Remodeling of the aortic root and reconstruction of the bicuspid aortic valve  Hans-Joachim Schäfers, MD, PhD, Frank Langer, MD, Diana Aicher, MD, Thomas.
Bicuspid Aortic Valves and Dilatation of the Ascending Aorta: Reply
Designing valves: An art or science?
Aortoscopy: a less invasive intraoperative method to assess the aortic valve  Eduardo A Tovar, MD, Jon R Sherman, MD, David M Weinberg, MD, Yonghun C Suh,
Presentation transcript:

The congenitally bicuspid aortic valve: how does it function The congenitally bicuspid aortic valve: how does it function? Why does it fail?  Francis Robicsek, MD, PhD, Mano J Thubrikar, PhD, Joseph W Cook, MD, Brett Fowler, RT  The Annals of Thoracic Surgery  Volume 77, Issue 1, Pages 177-185 (January 2004) DOI: 10.1016/S0003-4975(03)01249-9

Fig 1 Schematic drawings of the geometry of the three bicuspid aortic valves studied. Numbers in parentheses represent either the length of the free edge or the height of each leaflet in millimeters. Numbers without parentheses represent abnormalities in the respective valves. Valve A: (1) free edge of the leaflet is attached to the sinotubular ridge away from the commissure; (2) hole in the leaflet in the coaptation surface; (3) a raphe in the leaflet; (4) the line of attachment is almost flat; (5) the line of attachment is skewed. Valve B: (1) very tiny third leaflet; (2) very thick cordal structure; (3) considerably increased leaflet height; (4) very wide commissure. Valve C: (1) very thick raphe; (2) very long free edge; (3) flat attachment line; (4) very thick leaflet free edge; (5) thickened free edge region. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 2 Valve A: views in closed (a) and (b) open positions in a pulse duplicator. In the open position, the attachment of the free edge to the sinotubular ridge, away from the commissure, produces the appearance of two triangular “curtains.” A prominent raphe and the arrangement of collagen cords also may be noted. In the open valve, the leaflet separation is much less than the diameter of the aorta. (c) Silicone mold prepared at a pressure of 80 mm Hg shows the geometry of the sinuses, presence of raphe, orientation of collagen cords, configuration of the line of closure, curve in the leaflet surface, the contour of the line of leaflet attachment, and the protrusive nature of the leaflet surface. (d–i) Photographs taken at a high speed (500 fps) during the valve opening. The change in topography of the leaflet surface can be appreciated. (a) The leaflet with raphe in the closed valve. (d–i) Its surface is curved upward, indicating that a circumferentially oriented fold (wave) is traveling from the base to the free edge. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 3 Valve A: short-axis intravascular ultrasound images show cross-section of the aortic root. (a) Curved line of closure is evident. (b and c) Smaller leaflet separation is restricted at the free edge compared with that towards the base. (c) The raphe causes the base at 7 to 8 o'clock to appear thick. (d–f) Long-axis views show the leaflets during opening. Folds and kinks are clearly visible. (e and f) The open channel is dome-shaped. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 4 Valve B: (a and b) aortic views in the pulse duplicator reveal a third rudimentary leaflet (located at 5 o'clock). The closure line is straight in a. (c) Silicone mold prepared at a pressure of 80 mm Hg. (c) Ventricular aspect of the mold of valve. Note the elliptical shape of the aortic root and the extensive folding and creasing of the leaflet belly present even under diastolic pressure. Note the bulbous protrusion in the leaflet surface. (d-i) Photographs from the aortic aspect taken at a high speed (500 fps) during the valve opening. (e-g) During opening, the leaflet surface is curved upward even before the valve opens. Circumferentially oriented fold (wave) travels through the leaflet surface from the base towards the free edge. A bubble-like protrusion is visible in the leaflet surface at 11 o'clock, corresponding to the similar but inverted protrusion in the mold. (i) Fully open valve. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 5 Valve B: (a) short-axis intravascular ultrasound images show a straight line of closure and a wide commissure. (b) Opening is restricted at the free edge and (c) increases towards the base. (a) The aortic root is elliptical. (d) Long-axis views show coaptation surface as well as (e and f) folds and kinks in the leaflet as the valve opens. (f) The open channel is dome-shaped. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 6 Valve C: (a and b) aortic views in the pulse duplicator. (a) The contour of the closure line and the overall appearance is more like that seen in the trileaflet valve. (a) In the conjoined leaflet, enhanced thickness of the free edge and of the raphe can be noted. Also, a central hole is visible. (b) In the open valve, the raphe near the base of the leaflet appears to produce a partitioning membrane. The orifice of the valve is highly elliptical. (b) One leaflet moves well whereas the other moves only a little. (c) Silicone mold prepared at a pressure of 80 mm Hg. The valve has a central hole and silicone leaking through the hole may be noted. The raphe is prominent, and makes one of the sinuses look like two separate ones. The mold appears as if it is of a trileaflet valve with regurgitation. (d–i) Photographs from the aortic aspect taken at a high speed (500 fps) during the valve opening. Closed valve showing a hole at the center. Also, leaflet fusion, thick raphe, and thickened free edge of one leaflet is obvious. There is limited leaflet folding because one leaflet is very stiff and the other somewhat thicker and stiffer than those of valves A and B. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 7 Valve C: (a) short-axis intravascular ultrasound images reveal two unequal sinuses. (b) Leaflet separation is restricted near the free edge and (c) increases towards the base. (b) Increased thickness in the free edge of the leaflet at 4 o'clock. (d) Long axis views show the valve shut. (e and f) With the valve open, only one leaflet could be seen. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 8 (A) Digital modeling of a cusp of a bicuspid valve. (B) The stress distribution on the leaflets of the eccentric bicuspid valve. Because of asymmetrical geometry of the open valve, the blood flow path is forced toward the left by the leaflets. It resulted in an uneven stress distribution in the two leaflets. A high stress is present in one leaflet only. This is because the leaflet on the right needs to provide the force to alter the flow path. Such a high stress is seldom present in a normal trileaflet valve. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 9 (A) Flow and (B) stress patterns of an eccentric bicuspid valve. The valve opening is tilted to the left. The commissure attachment is 5 mm off from the center of the valve. Valve dimensions: annulus, 20 mm; sinotubular junction, 20 mm; leaflet height, 16 mm; leaflet free-edge length, 26 mm. The area of the orfice is approximately 50% of that in the nonstenotic valve. For the stenotic valve, the left ventricle needs to contract harder and, as a result, the blood may carry a higher momentum (energy, velocity) into the aorta. Consequently, the aortic arch needs to provide a larger force to turn the flow path into the descending aorta. This causes a higher and uneven stress distribution in the ascending aorta. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 10 Digital modeling of bicuspid valve 1 in a closed position. Note the extensive wrinkling and folding. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)

Fig 11 Folding and unfolding of the free edge of the leaflets is necessary for opening and closure of the normal tri leaflet (left) as well as for the bicuspid aortic valve (right). Note that whereas the former fully unfurls at both full opening and full closure, the maximum folding of the bicuspid valve occurs at full closure. The degree of folding is illustrated below. The Annals of Thoracic Surgery 2004 77, 177-185DOI: (10.1016/S0003-4975(03)01249-9)