Heat transfer Chapter 7.

Slides:



Advertisements
Similar presentations
Automobile Engine NO.4. NO.1 Mercedes-Benz E-class.
Advertisements

Electronics Cooling MPE 635 Mechanical Power Engineering Dept.
Ss Hefei, China July 19, 2011 Nuclear, Plasma, and Radiological Engineering Center for Plasma-Material Interactions Contact: Flowing.
Part F Practical Applications. 28. Fan-Cooled Enclosure of a PC System Physical System The physical system of interest is a fan-cooled enclosure containing.
Free Convection: General Considerations and Results for Vertical and Horizontal Plates Chapter 9 Sections 9.1 through 9.6.2, 9.9.
Extended Surfaces Chapter Three Section 3.6.
MECHANISM OF HEAT TRANSFER Mode of Heat transfer Conduction Convection
Extended Surfaces/Fins Convection: Heat transfer between a solid surface and a moving fluid is governed by the Newton’s cooling law: q = hA(T s -T  ).
CHE/ME 109 Heat Transfer in Electronics LECTURE 22 – ELECTRONICS COOLING MECHANISMS.
AAE450 Spring 2009 Slide 1 of 7 Orbital Transfer Vehicle (OTV) Thermal Control Ian Meginnis February 26, 2009 Group Leader - Power Systems Phase Leader.
Cooling of Chips in Circuit Boards. Problem One way to cool chips mounted on circuit boards is to encapsulate the boards in metal frames that provide.
Jed Goodell Jesse Williams. Introduction Problem How much heat does a particular heat sink dissipate How many fins are needed to dissipate a specific.
Heat Transfer Overview
CPU Cooling Benjamin Crummett. Objective Reduce CPU operating temperature. Reduce CPU operating temperature. Over clock the CPU without over heating it.
Free Convection: Mass Transfer Chapter 9 Section 9.10.
Chapter 2 Section 1  The sun provides nearly all of the energy which powers the atmosphere.  That energy comes to us in the form of electromagnetic.
External Flow: The Flat Plate in Parallel Flow
Heat Sink Selection Thermal Management of Electronics
Lab-1,Week 1, EML 3016 C- Spring 2003 Electronic Device Cooling A thin (assume zero thickness) electronic chip has a square shape of an area 5x5 cm 2,
Adapted from “Cooling Systems” – CTAE Information Technology Essentials PROFITT Curriculum.
HEAT EXCHANGER.
INTRODUCTION Definition:
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Submerged PC Cooling By: Patrick Hague Geoffrey Clark Christopher Fitzgerald Group 11.
COOLING SYSTEM IN IC ENGINES
EXAMPLE 27.1: A copper wire carries a current of 10 A. It has a cross- sectional area of 0.05 cm 2. Estimate the drift velocity of the electrons.
Chapter 4 Control Volume Analysis Using Energy. Learning Outcomes ►Distinguish between steady-state and transient analysis, ►Distinguishing between mass.
Analytical Modeling of Forced Convection in Slotted Plate Fin Heat Sinks P. Teertstra, J. R. Culham & M. M. Yovanovich Microelectronics Heat Transfer Laboratory.
Electronics Enclosures
2/28/05ME 2591 Electronics Cooling Reference: Cengel, Heat Transfer, 2 nd Edition, Chapter 15.
One-Dimensional Steady-State Conduction
Heat Transfer from Extended Surfaces Heat Transfer Enhancement by Fins
External Flow: Mass Transfer Chapter 7 Sections , 7.7, 7.8.
Heat Transfer Equations. Fouling Layers of dirt, particles, biological growth, etc. effect resistance to heat transfer We cannot predict fouling factors.
Cooling Systems. High temperatures can shorten the life expectancy of electronic components. High temperatures can shorten the life expectancy of electronic.
Introduction to Energy Management. Week/Lesson 9 part a Evaporative Cooling and Cooling Towers.
External Flow: The Flat Plate in Parallel Flow Chapter 7 Section 7.1 through 7.3.
Date of download: 5/28/2016 Copyright © ASME. All rights reserved. From: Numerical Simulation and Parametric Study of Heat-Driven Self-Cooling of Electronic.
Computer Hardware Components. Cases There are desktop cases and tower cases.
Heat Sinks and Component Temperature Control
AFE BABALOLA UNIVERSITY
Date of download: 9/27/2017 Copyright © ASME. All rights reserved.
Thermally managing high power devices using heat pipe assemblies
Ultra Quiet CPU Cooler CNPS80F Sales Guide
Unit 42: Heat Transfer and Combustion
INTRODUCTION : Convection: Heat transfer between a solid surface and a moving fluid is governed by the Newton’s cooling law: q = hA(Ts-Tɷ), where Ts is.
HEAT TRANSFER WITH EXTENDED SURFACES (FINS)
ECE Engineering Design Thermal Considerations
Date of download: 12/25/2017 Copyright © ASME. All rights reserved.
Extended Surface Heat Transfer
Written by Tim Keyser Georgia CTAE Resource Network 2010
Date of download: 12/31/2017 Copyright © ASME. All rights reserved.
Chapter 8 : Natural Convection
Concentric Tube (double-pipe) Heat Exchangers
Dr John Fletcher Thermal Management Dr John Fletcher
FREE CONVECTION – FIXED POWER TD1005
Heat Transfer in Extended Surface
FORCED CONVECTION AND EFFECTIVE VELOCITY
Heat Transfer.
Lecture 16 Aeration.
Heat Transfer from Extended Surfaces (Fins)
Thermal behavior of the LHCb PS VFE Board
Chapter 8 Heat Transfer.
Exercises. Introduction to Fins
THERMODYNAMIC IN ELECTRONICS
CHAPTER 12 MECHANISMS OF HEAT TRANSFER
Written by Tim Keyser Georgia CTAE Resource Network 2010
3 x Transformer boards ISO View Fans Oriented as in Super Micro Case
How to design the size of heatsink
Presentation transcript:

Heat transfer Chapter 7

7–28 A transformer that is 10 cm long, 6 7–28 A transformer that is 10 cm long, 6.2 cm wide, and 5 cm high is to be cooled by attaching a 10 cm 6.2 cm wide polished aluminum heat sink (emissivity 0.03) to its top surface. The heat sink has seven fins, which are 5 mm high, 2 mm thick, and 10 cm long. A fan blows air at 25°C parallel to the passages between the fins. The heat sink is to dissipate 20 W of heat and the base temperature of the heat sink is not to exceed 60°C. Assuming the fins and the base plate to be nearly isothermal and the radiation heat transfer to be negligible, determine the minimum free-stream velocity the fan needs to supply to avoid overheating.

7–55 The components of an electronic system are located in a 1 7–55 The components of an electronic system are located in a 1.5-m-long horizontal duct whose cross section is 20 cm 20 cm. The components in the duct are not allowed to come into direct contact with cooling air, and thus are cooled by air at 30°C flowing over the duct with a velocity of 200 m/min. If the surface temperature of the duct is not to exceed 65°C, determine the total power rating of the electronic devices that can be mounted into the duct.

Ch7 questions 14-16-20-21-24-27-28-30-32-39-40-44-46-48-52-55-57-58-60-64-66-68-69-70