Implant- Secured Dentures using Locator® Abutments

Slides:



Advertisements
Similar presentations
Altered Cast Technique
Advertisements

Complete Denture.
Lab Techniques for Flexible Partial Dentures
Repair, relining and rebasing
Zest Anchors, Inc. is a global leader in the manufacturing of dental attachments. Their new Locator Overdenture Abutment is on the cutting edge of dental.
Fabricating Removable Partial Denture Bases
Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.
Treatment of grossly resorbed mandibular ridge
Introduction to Removable Prosthodontics
بسم الله الرحمن الرحيم.
DR. NORA SHETA ASSISTANT PROFESSORS PROSTHODONTIC.
Almitech Implant System for implant retained overdentures. Mike Shulman, DDS Utilizing the Almitech Implant System to restore completely edentulous mandible.
Impression tray and impression technique
Impression procedure.
DOUBLE IMPRESSION TRAY TECHNIQUE A 55 year old male patient presented with a highly resorbed mandibular ridge and with three natural teeth. He did not.
INTRODUCTION - REMOVABLE PARTIAL DENTURE
Anatomic Abutment.
Copyright 2003, Elsevier Science (USA). All rights reserved. Removable Prosthodontics Chapter 52 Copyright 2003, Elsevier Science (USA). All rights reserved.
In partnership with Nobel Biocare Diagnosis and treatment planning for the replacement of missing teeth Module 1 | Session 4 Treatment planning and restoring.
32 Removable Prosthodontics. 2 Artificial structures replacing teeth and tissues Restore lost functions –Stabilize arch –Improve aesthetics Additional.
3shape Trios Intraoral Scanner CU Protocol
Introduction In Removable Partial Denture
Unless otherwise noted, the content of this course material is licensed under a Creative Commons Attribution - Non-Commercial - Share Alike 3.0 License.
1. Stability - Housing does not contact the fixture directly. - 3pcs of ceramic balls provide perfect retention.  Distributes masticatory force properly.
Copyright © 2006 Thomson Delmar Learning. ALL RIGHTS RESERVED. 1 PowerPoint ® Presentation for Dental Materials with Labs Module: Prosthodontics: Fixed.
PROSTHETIC PROCEDURE MANUAL BR SYSTEM. CEMENTED RESTORATION Impression Copings Set Screw Pick-up Transfer Implant Analog Cemented Abutment Angled Abutment.
What Is an Overdenture A complete denture that is supported and often
McCracken’s Removable Partial Prosthodontics. Chapter 10 & 19
Complete Denture Duplication
PowerPoint® Presentation for Dental Materials with Labs
Occasionally needed. How to avoid?? Careful diagnosis, treatment planning, adequate mouth prepara­ tions, and the carrying out of an effective partial.
The Atlantis Abutment  precision milled titanium alloy  ideal coronal preparation  correct path of insertion  perfect emergence profile straight path.
Laboratory stages of manufacture of complete dentures
Extra-oral photos Full Face SmileFull Face at Rest Lateral View.
Straumann® Bone Level Implant Prosthetic Product Portfolio
Removable partial denture framework try-in Dr Balendra Pratap Singh BDS, MDS, MAMS, FISDR, FPFA, FAAMP, ICMR-IF Assistant Professor Department of Prosthodontics.
Gold Abutment for bridge
Principles of complete denture prosthodontics.
REMOVABLE PROSTHETICS
Fabricating Removable Partial Denture Bases. (1) Factors Affecting Selection of Artificial Teeth (2) Altered Cast Technique (3) Procedures for Articulating.
 A thin shell crown or fixed partial denture can be made from any of the acrylic resins, and then that shell can be relined indirectly on a plaster cast.
©2013 Delmar, Cengage Learning. All Rights Reserved. May not be scanned, copied, duplicated, or posted to a publicly accessible website, in whole or in.
The Many Advantages of Dental Implants. If you are missing teeth due to an accident, tooth decay, or another oral disease, you may be a good candidate.
Next Generation Locator R-TX ™ Attachment Solution GMT Locator ® and Locator R-Tx TM is a registered trademark of Zest Anchors Inc. Distributed.
LABORATORY PROCEDURES FOR PROCESSING ACRYLIC DENTURES Dr Barbara Ndagire.
Altered Cast Technique
Clinical Protocol for Removable Partial Dentures
Guide Right™ CASE FOR ANGLED IMPLANTS
Atlantis® Crown Abutment – titanium, with composite, tooth no 26
Phases of partial denture treatment
Prosthodontics Introduction lec. 1
Adjustment of complete denture occlusion
Inter occlusal Record (Bite Registration)
DEPARTMENT OF PROSTHODONTICS
Repairs for RPD.
The altered cast technique
BORDER SEAL After finish the festooning of all polished surfaces and carving of the cast in the post dam area. Now the next step is to do border seal.
Flasking and wax elimination
Support for the Distal Extension Denture Base
Impressions for Complete Denture
NobelProcera® restorations for edentulous cases
Locator® Abutment Workflow presentation
Snappy™ Abutment – clinical cases
Delivery and insertion
Complete Denture Overview
Clinical Protocol for Removable Partial Dentures
Planning with the CrossFitTM PLAN Set
Planning with the CrossFitTM PLAN Set
Customized Impression Post
Presentation transcript:

Implant- Secured Dentures using Locator® Abutments Reline a Locator Denture- Replace Denture Caps Step-by-Step

Reline a Locator® Denture- Replace Denture Caps Step 1: Grind out Denture Caps from denture and, similar to a retrofit procedure, create a concave recess in the denture with a bur at each location where a new Denture Cap will be retrofitted during the reline process. LOCATOR® IS A REGISTERED TRADEMARKOF ZEST ANCHORS, INC. ALL RIGHTS RESERVED STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps Step 2: Place new Denture Caps on Locator Abutments. Note: These Denture Caps will act as impression copings at this step in the reline process. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps Step 3: Using a marking material, verify passive fit of denture on tissue with no contact to Denture Caps. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps Step 4: Apply impression tray adhesive to the internal aspect of the denture. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps Denture Caps, acting as impression copings, are picked up into impression Step 5: Apply impression material to the internal aspect of the denture. Take a reline impression with the patient in passive, centric occlusion utilizing a border mold impression technique. Send to lab. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps Analog Step 6: Lab places analogs into Denture Caps. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps Step 7: Lab pours master cast. Remove Denture Caps from impression and place on analogs. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps New Denture Caps retrofitted and cured into relined denture. Step 8: Lab relines denture on master cast with new Denture Caps in place. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps Black processing inserts inside the denture cap. Black processing inserts are used for relining the denture only and must be removed. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps Removal Tool Step 9: Lab “plucks-out” and removes black processing insert using the Removal Tool of the Locator Core Tool. STRAUMANN 23 February 2019 Image courtesy of Dr. Bob Vogel

Reline a Locator® Denture- Replace Denture Caps The replacement male is inserted with the male seating tool. Step 10: New Retention Rings are selected and placed into the New Denture Caps of the relined denture. STRAUMANN 23 February 2019

Reline a Locator® Denture- Replace Denture Caps The denture is then inserted in the patient’s mouth and if necessary occlusion is adjusted after checking for pressure spots. Step 11: When relined denture is returned from lab, place into patient, check for pressure spots, and adjust the occlusion. STRAUMANN 23 February 2019