SETTLING COLUMN ANALYSIS FOR FLOCCULATING PARTICLES (Type II settling)
Type II Settling Flocculent Settling Flocculating but not concentrated suspension. The diameter of particles changes. This means that there is not a unique settling velocity Increase in particle size caused by flocculation varies with time. Size and settling velocity will vary with depth. Take samples over the depth of the column at set time intervals. Mustafa Nasser 2012
Type II Settling Flocculent Settling
Type II Settling Flocculent Settling
Type II Settling Flocculent Settling
Type II Settling Flocculent Settling
Type II Settling Flocculent Settling xij is the mass fraction of particles remaining in suspension at depth i and time j, then the percentage of particles removed at that depth and time is
A further complication: Type II Settling Flocculent Settling A further complication: Concentration and settling velocity of particles are also a function of the total depth of settlement (i.e. the maximum depth through which they settle) The settling analysis must be carried out using a column having the same depth as the proposed settling basin. Mustafa Nasser 2012
Type II Settling Flocculent Settling Ways of performing the calculation (a) BY USING INTERPOLATED VALUES OF r The following calculations are carried out in the table below: (i) identify the residence time t0 (ii) interpolate for the concentration profile at this time; (iii) convert the concentration profile to r-values (iv) calculate the values of Δr; (v) identify the average depth corresponding to each value of Δr; (vi) form the product z Δr; (vii) find the sum of all the values of z Δr; (viii) divide this by the depth of the column.
Average concentration at t (B) THE CONCENTRATION PROFILE IN THE SETTLING COLUMN As there is information about the concentration profile throughout the column the average concentration in suspension at any time, t, is Average concentration at t Concentration at t as a function of z The mass fraction remaining in suspension must be and the removal = (1 x0(t)) Mustafa Nasser 2012
By (a) using interpolated values of r (b) By considering the concentration profile
Interpolate for the concentration profile at 105 minutes
The mass fraction remaining in suspension must be (b) By considering the concentration profile The mass fraction remaining in suspension must be and so the removal is Mustafa Nasser 2012
Depth Time of sampling /(min) Average /(m) 90 120 105 Concentration dz C(av)dz 0.0 0 0 0 22 0.5 11 0.5 50 38 44 61.5 0.5 30.75 1.0 93 65 79 92.25 0.5 46.125 1.5 118 93 105.5 114 0.5 57 2.0 135 110 122.5 128.15 0.5 64.125 2.5 145 123 134 139 0.5 69.5 3.0 155 133 144 SUM = 278.5 Mustafa Nasser 2012
Recall the average concentration is mg ℓ−1 So if the original concentration was 250 mg ℓ−1 That is the mass fraction left in suspension is 0.37 Thus 1 – 0.37 = 0.63 is the mass fraction removed Mustafa Nasser 2012
Type III and Type IV Settling
Type III and Type IV Settling
Type III and Type IV Settling
Type III and Type IV Settling
Types of Sedimentation Tanks
Sedimentation Tanks
Types of Sedimentation Tanks Horizontal Flow Tanks – Rectangular Tanks
Types of Sedimentation Tanks Horizontal Flow Tanks – Rectangular Tanks
Types of Sedimentation Tanks Horizontal Flow Tanks – Rectangular Tanks
Types of Sedimentation Tanks Horizontal Flow Tanks – Rectangular Tanks Inlet
Types of Sedimentation Tanks Horizontal Flow Tanks – Rectangular Tanks Inlet
Types of Sedimentation Tanks Rectangular Tanks-Settling Zone
Types of Sedimentation Tanks Rectangular Tanks-Sludge Zone
Types of Sedimentation Tanks Rectangular Tanks-Outlet
Types of Sedimentation Tanks Rectangular Tanks-Outlet
Types of Sedimentation Tanks Rectangular Tanks-Outlet
Types of Sedimentation Tanks Rectangular Tanks-Outlet
Types of Sedimentation Tanks Circular Tanks
Types of Sedimentation Tanks Circular Tanks
Types of Sedimentation Tanks Circular Tanks –Inlet Design
Types of Sedimentation Tanks Circular Tanks –Outlet Design
END