Signal studies OUTLINE 1- Signal extraction

Slides:



Advertisements
Similar presentations
20 Abr 2004Udine bootcamp1 First Analysis Results of the Crab Nebula and Mrk421 M. López Moya U.C.M. 1.Analysis chain 2.Mrk421 Camera rotation study Light.
Advertisements

AGS pp Status Feb. 6, 2015 RSC Meeting Haixin Huang.
Calibration Munich group version Checks. SWM UD, April 2004Nadia Tonello, MPI 2 Idea Calibration runs: same number of photons in all PMs Flat fielding:
19. April, 2004, Udine WorkshopKeiichi Mase Results from an Analysis of Muon Rings Keiichi Mase.
SPD commissioning Ricci, Míriam, Daniel, Edu, Hugo et al. from 1.
Checking the Acd hardware veto setting The hardware veto is generated in the front-end electronics Discriminator with coarse and fine settings Both are.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
H Yepes, C Bigongiari, J Zuñiga, JdD Zornoza IFIC (CSIC - Universidad de Valencia) STATUS OF THE ABSORPTION LENGTH MEASUREMENT WITH THE OB SYSTEM ANTARES.
Preliminary Results of the Test Run at SLAC Petra Hüntemeyer.
VELO ADC vs Charge Calibration Jianchun Wang April 16, 2008 This is an update to the presentation at April 11 st VELO Group Meeting. A new scan data of.
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting Apr, 16, 2008.
ACD calibrations Pedestals Measured from online script Measure PHA w/ HV off, no charge injection Use cyclic triggers ~ ADC counts, very narrow.
CFT Calibration Calibration Workshop Calibration Requirements Calibration Scheme Online Calibration databases.
ACORDE REPORT Pedro Podesta UAS Mexico. Geometry ( No changes) Alignment (No changes) QA (No changes ) Shuttle (In progress) To do Outline.
28 February, 2003 STAR Collaboration meeting Status of the dE/dx calibration Yuri Fisyak.
Leroy Nicolas, HESS Calibration results, 28 th ICRC Tsukuba Japan, August Calibration results of the first two H·E·S·S· telescopes Nicolas Leroy.
1 TOF Aging Discussion Background information Summary of results so far Examples of gain loss mechanisms Diagnostics Possible scenarios for 2006 Discussion.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
1 HBD Commissioning (II) Itzhak Tserruya HBD group meeting November 28, 2006 Progress from October 3 to November 28, 2006.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Updates on GEMs characterization with APV electronics K. Gnanvo, N. Liyanage, K. Saenboonruang.
Friday, April 23, 2004University Udine, Italy Razmick Mirzoyan MPI Munich Where do we stay after having seen the first signals from Crab and Mrk-421 ?
TDC-Related Processors in MarlinTPC/branches/oschfer by Oliver Schäfer MarlinTPC EVO-Meeting, 30 th April 2009 University of Rostock DESY Hamburg EUDET.
Commissioning of the ECAL A-side Irina Machikhiliyan, Reference data samples: #45498 PM HV nominal, LED LV = nominal, 5K of 5 TAE events, LED.
1 xCAL monitoring Yu. Guz, IHEP, Protvino I.Machikhiliyan, ITEP, Moscow.
Analysis chain for MAGIC Telescope data Daniel Mazin and Nadia Tonello Max-Planck-Institut für Physik München D.Mazin, N.Tonello MPI for Physics, Munich.
GEM-TPC Resolution Studies ECFA/DESY LC Workshop Prague, November 2002 Dean Karlen University of Victoria / TRIUMF.
1 Latency and pedestal test Mikko Nykänen
On behalf of joint ITEP / IHEP team: A. Arefiev, N. Filimonov, T. Kvaratskheliya, I. Machikhiliyan, P. Shatalov, T. Zakoryuchkina, A. Zhokhov, S. Zvyagintsev.
The islands method in the image analysis of atmospheric Cherenkov Telescopes data Nadia Tonello and Keiichi Mase Max-Planck-Institut für Physik München.
T0 offline status Alla Maevskaya for T0 team 8 March 2011 ALICE offline week.
MPPC Saturation Corection Idea -> how to do. MPPC Gain measurement To apply saturation correction to the beam data, all MPPC are needed to be calibrated.
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
Feature Extractor Dima Chirkin, LBNL The future is here.
Forward Carriage Commissioning CLAS Collaboration Meeting 6/19/2015CLAS12 CalCom Status Update1 ECAL PCAL FTOF Panel 1A FTOF Panel 1B Detector Status PMT.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
PMT Calibration R.Sawada 7/Jan/2007. Time calibration Method was talked at the previous meeting. The problems which was shown before were because I used.
Pixel Results from CRAFT09 U. Langenegger (PSI), G. Giurgiu (JHU) Pixel General Meeting November 10, 2009.
HBD Report Craig Woody BNL DC Meeting January 7, 2009.
M. LefebvreATLAS LAr week, November 19th HEC-EMEC beam test data analysis Filtering weight synchronization and timing issues TDC timing Cubic timing.
1 EMCAL Reconstruction in Pass pp 900 GeV 29/03/2010 Gustavo Conesa Balbastre.
Summary of IFAE analysis of Crab and Mrk421 for February & March 2004Udine bootcamp, 19th-22nd April STATUS OF DATA ANALYSIS Javier Rico for the IFAE group.
1 ECAL/PRS quality check with LED system Outline  Introduction, how to use LED time scan data for a detector quality check;  Last collected data of the.
Comparison of MC and data Abelardo Moralejo Padova.
PMT time offset calibration (not completed) R.Sawada 27/Dec/2007.
1M. Ellis - MICE Tracker PC - 1st October 2007 Station QA Analysis (G4MICE)  Looking at the same data as Hideyuki, but using G4MICE.  Have not yet had.
Sensitivity of HO to Muons Shashi Dugad for HO group India-CMS Meeting 6-7 Oct
Laser Measurements (as comparison to test beam data) Florian Lütticke University of Bonn 9 th VXD Belle 2 Workshop Valencia,
1 XCAL LED quality check and time alignment consideration CALO meeting Anatoli Konoplyannikov [ITEP / LAPP] Outline  CALO sub-detector status.
Proposal for the after-pulse effect suppression  Observation of pulses and after-pulses  Shape measurement  Algorithm  Results  Efficiencies for after-pulse.
Beam detectors in Au+Au run and future developments - Results of Aug 2012 Au+Au test – radiation damage - scCVD diamond detector with strip metalization.
Feb C.Smith UVA EC energy calibration – g13 pass0 For pass0 data were cooked with CALDB calibration constants reset to nominal 10 channels / MeV.
Momentum and Momentum Spread Measurements
Daniel Mazin and Nadia Tonello Max-Planck-Institut für Physik München
Pre-calibration of PM gain by photo-statistics
PMT characterisation for the KM3NeT Project
EZDC spectra reconstruction and calibration
Weekly PDL report (Jul 7-14)
The Silicon Drift Detector of the ALICE Experiment
The Standard Analysis chain
SANE Cherenkov - Bigcal Efficiency Update
Analysis of FADC single-crystal data
SuperB LNF meeting March 21st 2012 Marcello Piccolo
PCAL Cosmic Ray Tests Progress Report C. Smith μ U V W MODULE 2
Pulse Shape Fitting Beam Test September, October CERN
Calorimeter calibrations with Flight Software.
Status report Minjung Kim
Using Single Photons for WIMP Searches at the ILC
Slope measurements from test-beam irradiations
Status of the Calibration
Presentation transcript:

Signal studies OUTLINE 1- Signal extraction 1.1- Fixed window vs Slide window in calibration 1.2- Fixed window vs Slide window in cosmics 2- Calibration of the data (comments) 3- Hillas parameters in ON-OFF data

David Paneque, MPI Muenchen 1.1- Fixed window vs Slide window in calibration Fitted Charge inner pixels Fixed window (3-10 slide) Slide window (6 slides) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.1- Fixed window vs Slide window in calibration Fitted Charge Outer pixels Fixed window (3-10 slide) Slide window (6 slides) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.1- Fixed window vs Slide window in calibration RMS pedestal Inner pixels Fixed window (3-10 slide) Slide window (6 slides) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.1- Fixed window vs Slide window in calibration RMS pedestal Outer pixels Fixed window (3-10 slide) Slide window (6 slides) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.1- Fixed window vs Slide window in calibration Reduced / <Q> for inner pixels Fixed window (3-10 slide) Slide window (6 slides) Mean = 0.240 Sigma = 0.018 Mean = 0.235 Sigma = 0.017 <Nphe> = (<Q> / ) 2 x F2 = 23 ph. 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.1- Fixed window vs Slide window in calibration Reduced / <Q> for outer pixels Fixed window (3-10 slide) Slide window (6 slides) Mean = 0.152 Sigma = 0.016 Mean = 0.140 Sigma = 0.017 <Nphe> = (<Q> / ) 2 x F2 = 63 ph. 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.1- Fixed window vs Slide window in calibration Conversion factors for inner pixels Fixed window (3-10 slide) Slide window (6 slides) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.1- Fixed window vs Slide window in calibration Conversion factors for inner pixels Fixed window (3-10 slide) Slide window (6 slides) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.2- Fixed window vs Slide window in cosmics Slide window produces a SIZE about 30-40 % higher than Fixed window (3-10 slide) -->> See Munich group web page Maxim and Hendrik studied the arrival times of pulses from Cosmics in the FADC slices. Pulses DO arrive quite late Fixed window misses part of the signal This explains PARTLY discrepancy between Berlin’s signal (200 phe) and Munich signal (350 phe) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.2- Comments on the calibration of the data Inspection of the calibration runs before calibrating data (MANUALLY) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen CONVERSION FACTORS for all calibration runs taken In Crab Feb 15th observations 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen Inspection of individual conversion factors evolution Fitted charge vs Calibration run for pixel 200 (Crab Feb 15th) 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen Inspection of individual conversion factors evolution Fitted charge vs Calibration run for pixel 200 (Crab Feb 15th) 24/02/2019 David Paneque, MPI Muenchen

Rejection (Set conversion factor to ZERO) of those pixels with “strange” behaviour <Q> < 50 ADC counts Reduced /<Q> away by more than 4 sigmas of the distribution (inner/outer) Mean = 0.235 Sigma = 0.017 Mean = 0.140 63 ph. 23 ph.

David Paneque, MPI Muenchen Rejection (Set conversion factor to ZERO) of those pixels with “strange” behaviour 24/02/2019 David Paneque, MPI Muenchen

David Paneque, MPI Muenchen 1.2- Comments on the calibration of the data Inspection of the calibration runs before calibrating data (MANUALLY) Rejection of calibration runs in order to not destroy data Usage of “closest” calibration run to calibrate a given data run (regardless of ON-OFF) in order to correct for drifts in PMT response (PMT HV ??) Rejection of those pixels with “strange” behaviour This procedure can OBVIOUSLY be improved. It has been just a first approach to the be able to analyze data “in a decent way”… 24/02/2019 David Paneque, MPI Muenchen

1.2- Comments on the calibration of the data THIS IS JUST A TEMPORAL SOLUTION. STILL A LOT OF WORK TO BE DONE TO UNDERSTAND REASONS FOR THESE DEFFICIENCIES What is the reason for “corrupted” calibration runs, conversion factors drifts, “strange pixels” ?? Problem with PMT HV ? DAQ/FADC Problem ? Why OUTER pixels have a conversion factor of only 2.7 Times larger than INNER pixels ? Why do they have such a “wide” charge distribution ? Why do they have such a large dispersion in conversion factors ? Lower and larger dispersion in “effective QE” Problem with Inter-dynode collection efficiency (different F factor…) In my opinion, a group of people should take the responsibility of checking IN DETAIL (Runs, pixels, events) calibration data, and later cosmic data, in order to understand and correct ALL the problems in the pixel chain.

David Paneque, MPI Muenchen 1.3- Comparion ON-OFF DATA 24/02/2019 David Paneque, MPI Muenchen