Multiparameter Display System

Slides:



Advertisements
Similar presentations
Data Collection. Status LEDs 5 MP Camera Touch Screen GNSS Receiver Light Sensor SD Card Slot.
Advertisements

easyEmission - 1st Steps & Overview
Unit Test Calibration Training
Data Collection Device (DCD) Job Aid – Burn-in In DOIS Log onto DOIS. Click Options on the DOIS menu bar. Click on Utilities. Click DCD Software Burn-In.
Fluke thermometer 54II Press green button to turn the thermometer on or off. If it does not turn on replace batteries.
Using the Unity 98 Cordless Response System Directions : Courtesy of IHC public relations.
EPOCH 1000 File Management Data Logging and Reporting
Kuskokwim Watershed Council Water Quality Training Workshop
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
1 Starting & Stopping Motors Pico Pico LAB#4. 2 Program a series of three basic ladder logic rungs. These basic rungs are the most common rungs found.
TrendReader Standard 2 This generation of TrendReader Standard software utilizes the more familiar Windows format (“tree”) views of functions and file.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
Working with GPS Stephen M. Kiama (MSc) [Geo-information Specialist]
Creating a Web Site to Gather Data and Conduct Research.
Navigation 3 GPS for ICS Data Transfer Review of DNR Garmin Uses Download Upload.
Developed By Information Technology Services University Of Saskatchewan.
© 2007 Ideal Industries 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.
How do I export the Address Book to Excel? The first step is to go to "Address Book Report" under Admin Only menu Choose the fields you want. note that.
Overview of MSWS Control of 212-LC July 15, 2006.
JDS5 Training Guide. On Start Up you will see this screen click the OK button Click OK.
Program a Gas EndPoint. 2 SENSUSAR5001 You will need a AR5001 or AR5002 Handheld unit connected by a serial cable to a 900 Unit Field Tool. Connected.
Important! Be sure to connect the communication cable to your computer before opening the Aqua4Plus Lite software. (Click to continue)
PRO OX ® -100 Kit PROGRAMMABLE DIGITAL OXYGEN MONITOR US & FOREIGN PATENTS ISSUED & PENDING STATE-OF-THE-ART TECHNOLOGY FOR PRECISE OXYGEN MONITORING MADE.
Fab25 User Training Cerium Labs LabCollector - LIMS Lynette Ballast.
Hardware Configuration Guide Configuring Dongles and Creating Barcodes for Devices Used with VSC.
5/14/2003Sprint TekNet IP Train the Trainer1 Open TekNet Software If working at a client station, enter the IP address of the server and mark page as a.
After Construction Name: Per #:.
T3/Tutorials: Data Submission
ICE Integrated Cloud Environment Cloud Scanning and Mobile Printing
THIS IS THE OPENING SCREEN
Measurement Equipment
Word Lesson 1 Word Basics
NEWCNT Import/load option
Exploring Computer Science Lesson 6-5
                                                                                                                                                                                                                   Your basic Windows keyboard
Chapter 1 Getting Started
IPOM and E-Booking.
A Software for Weighing Systems
Fulton County Public Library
Microsoft Excel 101.
Central Document Library Quick Reference User Guide View User Guide
Basic Computing for Teachers
Science Learning Center Chemistry Pre-laboratory Tutorials
Roller Coaster Design Project
office.com/setup installation and Activation
office.com/setup download,installation and Activation support guide
ALEPH Version 22 Beginning Cataloging
Pico Pico LAB#1 Starting & Stopping Motors.
Repair in Control Center
MCS-Connect Change all frames to windows
G450 and G460 battery pack maintenance
Updating instrument firmware
HHCApp Auditors.
Exploring Computer Science Lesson 6-5
OdaStat-G – Getting Started with the OdaLog Type L2
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Cisco 7925 Phonebook Userguide
P-Series Power Meter Firmware Upgrade Process
Add a dues payment to the Dues manager module for the Grand Lodge of Nebraska LSI Lodge Secretary Interface online Membership Database.
Grauer and Barber Series Microsoft Access Chapter One
Year 9 Entry Level Computing
LEGO Education - Mindstorms EV3 - Computer/control center – The Brick
Main Unit Establishment
Reporting 101 Keenan & Mona.
G&H Radiometer/Photometer Reset Notes
Department of Engineering Science EE 465 (CES 440) - Intro
Nellcor™ Bedside SpO2 Patient Monitoring System, PM100N - Home use
Presentation transcript:

Multiparameter Display System 650 MDS Multiparameter Display System

Outline Front & Rear Covers Keypad & Characters 650 Main Menu Interfacing with Sonde Setting up a Logging Run Setup Logging Files Collect Data View Data on 650 Download Data to PC and View Data Export Data

Front Cover Display On/Off Arrow Keys Backlight Key Escape Key Enter Key Handstrap Keypad MS-8 Connector Strain Relief Lanyard

Rear Cover Accessory Connections Screws Barometer Patch Vent Battery Lid Screws Accessory Connections

Keypad 1 = 1 2 = ABC2abc2 3 = DEF3def3 4 = GHI4ghi4 5 = JKL5jkl5 6 = MNO6mno6 7 = PQRS7pqrs7 8 = TUV8tuv8 9 = WXYZ9wxyz9 - = Minus/Hyphen 0 = 0 . = Period/Decimal Point

Interfacing a 650 with a Sonde 650 MDS Integral or Detachable Field Cable YSI 6-Series Sonde

Operating the 650 Menus

650 Flow Chart 650 Main Menu Run Screen Continued... Sonde run Sonde menu File Logging Setup System Setup Run Screen Continued... Directory Upload to PC View file File memory Delete all files Interval Use site list Store Barometer Store Lat and Long Store site number Edit Site List Version Date & Time Power Sonde Baud rate to sonde Shut off time Comma radix ID Circuit Board Serial # Barometer Units Calibrate Barometer

“Report setup” includes a list of all enabled sensors. Sonde Menu Flow Chart Sonde Menu Discrete Sample Unattended Sample Conductivity DO % DO mg/L Various other Parameters Run Directory Upload to PC Quick Upload View File Quick view file Delete all files Calibrate Version Date Time Bat volts Bat life Free bytes Logging File Status Date & Time Comm setup Page length Instrument ID Circuit Board SN GLP filename SDI-12 address Language System Report “Report setup” includes a list of all enabled sensors. “Sensors enabled” gives a list of all available sensors and shows if they are enabled. Sensor Cal constants Setup Sensor Data filter Advanced

Calibration

650 Logging Available Memory Low Memory 12 File Names 100 Site Names High Memory 35 File Names

Logging to the 650 Simple Logging From the Main Menu highlight Logging setup. Press The ‘Use site list’ should be inactive. Set the interval to 2 seconds (00:00:02) and press Press Highlight Sonde run and press

Logging to the 650 Simple Logging You should now see the Run screen With 650, “Log one sample” is highlighted

Logging to the 650 Simple Logging Enter “Pond” for a file name and Press Arrow down and enter site description press Arrow up to highlight OK and press

Logging to the 650 Under Different File Names Press until you return to the Main Menu Under Logging Setup, Highlight ‘Use site list’ and press Highlight ‘Edit Site List’ and press

Logging to the 650 Using a Site List For file name enter “BLUELAKE”. For each site name and site number, set them up as in the example below:

Logging to the 650 Using a Site List Once your site list is set up, press until you reach the Main Menu. Highlight Sonde run and press Select ‘start logging’ under the 650 menu and press

Logging to the 650 Using a Site List

Logging to the 650 Parameter mismatch

Parameter mismatch Use this chart to Troubleshoot a Parameter Mismatch:

Additional Hints Adjust contrast by holding down the Back Light key and pressing the Up / Down arrow keys When logging directly to 650, make sure report menu in Sonde is setup with what Parameters you wish to capture. You can log data to Sonde if memory in 650 gets full while in the field.

FILE MANAGEMENT - Viewing Data on 650 - Downloading Data from 650 to PC You will need your PC adapter cable. From the 650 Main menu, File Upload to PC Select your file name, press

Interfacing a 650 & PC for File Management 650 MDS PC Interface Cable Personal Computer

Open EcoWatch Open Com Port Download Data from 650 to PC

Select only the Parameters of Interest

Data Display #1

Data Display #2

Readings on Plot Readings of any particular point on plot press and hold the right mouse button

Export Data

Open Excel (find file and open using wizard)

Questions….