Objectives Finish with tracer gas measurement Blower door and duct bluster measurements.

Slides:



Advertisements
Similar presentations
Energy Efficient Heating Ventilating and Air Conditioning.
Advertisements

TOUR OF NIST MANUFACTURED RESEARCH HOUSE Andy Persily, Steve Nabinger, Steve Emmerich, Cindy Howard Reed Building and Fire Research Laboratory National.
Chemical Fume hood or Biosafety Cabinet
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
PowerPoint ® Presentation Chapter 15 Troubleshooting and Mitigating IAQ Problems Troubleshooting and Mitigating IAQ Problems Overview of Non-IAQ Problems.
1 Application of for Predicting Indoor Airflow and Thermal Comfort.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Problems With Determining Oxygen Deficiencies in Ratios Used for Assessing Spontaneous Combustion Activity Darren Brady Manager OHECC Simtars Department.
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
Residential Ventilation in the Pacific Northwest Field Study of Mechanical Ventilation Effectiveness in Tightly Constructed Houses David Hales Washington.
PowerPoint ® Presentation Chapter 5 Handheld Meter Testing IAQ Complaints Measurement and Testing Air Properties Handheld Meter Testing for Contaminants.
Ventilation Systems As Control Measures. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit.
Ventilation Effectiveness & Indoor Air Quality Douglas Spratt February 2001.
The House as a System 1. Air Temperature and Water Vapor.
Station 3 ?? Air Meters Combustion Analyzer Carbon Monoxide Carbon Dioxide Particles Air Flow Vane Anemometer Exhaust Flow Box Pressures CAZ Test.
HVACR416 - Design Air Distribution Air Properties and Behavior Important properties of interest include: o Weight of air. o Manner in which air.
Reactors . ä Reactor: a “container” where a reaction occurs ä Examples: ä Clear well at water treatment plant (chlorine contact) ä Activated sludge tank.
Objective Finish with: Heat Flux & Relative Humidity Measurement Pressure measurement Start tracer gas measurement.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Blower Door Basics WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Objectives Blower door and duct bluster measurements - Theory and lab
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
The Energy Conservatory
TRI MARTIANA.  A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes,
Air Quality Controls Engineering Controls Administrative Controls Personal Protective Equipment.
Measurements of improved stoves distributed by AHDESA Presentation by Tami Bond 15 July 2006.
Implementing Demand Controlled Ventilation to Meet ASHRAE Standard By Klas C. Haglid, P.E., R.A., CEM 1.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Indoor Environmental Quality: Investigating the Problem
VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Objectives Finish talking about ways to minimize ventilation losses Discuss role of ducts in building energy use Describe coheating test methodology Interpret.
Michael Logsdon, Ben Larson, David Baylon 13 December th Avenue NE, Seattle, WA (206)
MODEL-BASED DETERMINATION OF HYDROGEN SYSTEM EMISSIONS OF MOTOR VEHICLES USING CLIMATE- CHAMBER TEST FACILITIES Dr. Martin Weilenmann.
ASHRAE A Ventilation Standard for Residential Structures Ventilation and Acceptable Indoor Air Quality in Low- Rise Residential Buildings.
Ben Larson 1 November th Avenue NE, Seattle, WA (206)
Lecture Objectives Answer your questions related to CFD software Ventilation Effectiveness Thermal Comfort.
HVACR416 - Design IAQ / Ventilation / Pathways. Ventilation Most air handling units distribute a mix of outdoor air and re-circulated indoor air. Some.
Michael Logsdon, Ben Larson, David Baylon 13 December th Avenue NE, Seattle, WA (206)
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
Minimizing Structural Energy Loss Andrew Layman Lisa Phillips.
Objectives Finish air cleaner problem Measure ventilation rates Focus on smaller buildings.
Air quality made simple A Balanced Approach Whole House Ventilation and IAQ Airflow Control Make-up Air Solutions Application by Geographic Region.
Indoor Air Quality Modeling. Purpose of Indoor Air Quality Modeling To estimate the indoor air pollutant concentration in a building To estimate the indoor.
Lecture Objectives -Finish with age of air modeling -Introduce particle dynamics modeling -Analyze some examples related to natural ventilation.
HEATING AND COOLING SYSTEMS
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
Radon Mitigation using Ventilation Assessment Tool Group 9 William Allred Joshua Chastain Daniel Diaz Ryan Nester.
Objectives Ventilation analysis with HOP Human exposure/IAQ Ventilation and energy.
VENTILATION AND FENESTRATION
Objectives Propose residential system related final project –Compare VAV systems with DOAS systems.
Review Project 1 Define Project 2 Define parameters for Thermal Comfort and Air Quality analyses in CFD Lecture Objectives.
Day 3 Part 3 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Reactor Models for Ventilation Modeling Solve differential equation Manipulate terms Ventilation rate Set up and solve generic problem.
CHAPTER 6 Gases and Vapors. Learning Objectives Describe the various properties of the chemicals that are most important to the practice of industrial.
Part 9 Technician’s Guide & Workbook for Duct Diagnostics and Repair
ASHRAE Annual Conference 2014 July 2, 2014
Lecture Objectives Discuss: Project 1 Diffuser modeling
Lecture Objectives Learn about particle dynamics modeling
Chapter 3B: INDOOR AIR QUALITY
CHAPTER 3 VENTILATION.
Things you need to know before you play the game
Lecture Objectives Review for exam Discuss midterm project
Ventilation Measurement Tracer Gas Decay Testing
Chapter 3B: INDOOR AIR QUALITY
Chapter 3B: INDOOR AIR QUALITY
Chapter 6B: INFILTRATION CALCULATION
Presentation transcript:

Objectives Finish with tracer gas measurement Blower door and duct bluster measurements

Tracer gas and IAQ Applications Quantification of outside air Air distribution system efficiency –Air change Efficiency –Contaminant removal effectiveness Leak detection House/chamber/duct/… Duct flow Re-entrainment of exhaust air into ventilation system Simulate toxic pollutant distribution Many other applications

A Good Tracer Gas? Non-toxic Environmental friendly Colorless and odorless Easily detectable Inert No other sources

Common Tracer Gases Used Carbon Dioxide Nitrous Oxide Freon Helium Sulfur Hexafluoride

Application 1:Quantification of outside air Volumetric Air Measurements Standard Test –ASTM E (2006) Available by the UT library website Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution

ASTM E741 Test Method Different methods: –Concentration Decay (or concentration increase) –Constant Injection

Concentration Decay Method Inject predetermined volume of gas into room Mix room air to get uniform concentration Monitor gas concentration decay Aim for 10 samples over measured time Use reactor model to predict concentrations

Theoretical Basis Space balance V V C in N Source C out V ol ·dC/d = V·C in -V·C out +N 0 If C in = constant & V ol /V = ACH dC/(C in -C out ) = ACH· d Integrate: ……. ACH =1/ Δ ·{ln[C in ( = Δ )- C out )]- ln[C in ( =0)- C out )]}

Concentration Decay Method Air Change Rate: In the case of zero inlet concentrate and perfect mixing in the space ACH =- (ln C 2 - ln C 1 )/Δ (in hours) C 1 = Tracer Gas Concentration at start of test C 2 = Tracer Gas Concentration at end of test

Tracer gas result [minutes]

Decay Test Advantages –Dont need to release precise amount –Dont need to measure volume (if C out = 0) Disadvantages –Need to keep building well-mixed –Recontamination from buffer spaces –House needs to stay in one condition for entire test

Single zone Example: Coffee Houses Lohaus and Waring (2006) ArE 381E Course Project

How do you estimate uncertainty? 1.Use standard error of slope 2.Follow ASTM E741 –ΔACH < 10%

Advanced Tracer Gas Testing Multi-zone flows –Easiest – Use several unique tracer gases –Harder – Use flow and mass balances

Consider Two-Zone Building (non-perfect mixing) V1V1 V2V2 V4V4 V3V3 V1V1 V2V2 E vdAvdA V6V6 V5V5 Tools Mass balance on tracer gas Mass (flow) balance on air Measured concentrations in each space º º º º º º

Equations How many unknowns? Equations? Flow direction for interzonal flow Air exchange rate for spaces Sums of flows

Solution procedure Reduce mass balance to one equation by solving C 2 equation for C 1 and substituting into C 1 equation –2 nd order ODE –Same thing for C 1 equation 6 unknown flows –Overall flow balance can be used to get two unknown flows –Measured tracer gas concentrations can be used to eliminate two more flows –Additional data needed for solvable system We need to use multiple tracer gasses! Or we need to measure flows with flow meters!

Example 2 Air distribution system efficiency How well is outside supply air distributed to breathing zones in occupied areas? Air exchange efficiency ASHRAE Standard 129 – Measuring Air Change Effectiveness Uses Tracer Gas Techniques Age-of-Air Measurements

Why Worry About Good Mixing? Poor Mixing Occupant complaints ASHRAE Standard, Ventilation for Acceptable Indoor Air Quality ASHRAE Standard is based on amounts of outside air getting to breathing zone not to supply air louvers Short – circuiting airflow patterns Where a significant portion of supply air flows directly to the exhaust, bypassing the occupied portion (breathing zone) of the ventilated space.

Air Exchange Effectiveness The definition is based on a comparison of the age of air in the occupied portions of the building to the age of air that would exist under conditions of perfect mixing of the ventilation air.

Age of Air The age of the air at a give location is the average amount of time that has elapsed since the air molecules at that location entered the building. Amount of time outside air has been in an area Two Methods of determination –Step-up constant tracer gas injection –Tracer gas concentration decay

How to measure Age of Air? Step down method: Injection and mixing –Air in the room is marked with tracer gas (injection and mixing) –Ventilation turned on Age of Air Measurements –Locations of interest –In the exhaust (C)

Constant Injection V = N / (C out - C in ) º V º V º C in N Source C out You need to get to steady state injection

Constant Injection Advantages –Can determine time-dependence of air exchange rates Disadvantages –Need to keep building well-mixed –Recontamination from buffer spaces –Need to have mass flow controller –Need to measure volume (for ACH( ))

How to measure Age of Air and Air Exchange Effectiveness Age of air at a location = Average tracer gas level during test Tracer gas level at beginning of test Air change effectiveness (E) E = < 1.0 (less than perfect mixing) E = 1 (perfect mixing) avg age of air – Exhaust avg age of air – age of air in breathing zone E = avg age of air =

Significance of Air Exchange Effectiveness ASHRAE Standard Ventilation for Acceptable Indoor Air Quality - Outside air requirements = QA/E as E decreases, OA should increase US Green Building Council LEED Rating requires an E > 0.9 in all ventilated zones

Tracer Gas Instrumentation

Tracers which we use SF 6 Gas analyzer –ppm with IR absorption or photo-acoustic IR –ppb with GC/ECD CO 2 Tracers gas analyzer ( CO 2 sensor )

31 Infiltration/Leakage Measurements (Calibrated Fans) Flow going through fan is calibrated to pressure rise across fan –If you measure pressure, than you know flow Requires very smooth inlet and outlet conditions Often have to restrict flow to get measurable pressure signal for low flows Examples: –Blower door and Duct Blaster 31

Fan Pressurization In 1970s, smoke evacuation fans used to find air leakage 1. Install blower door 2. Use fan to create artificial pressure difference between inside and outside 3. Use smoke stick (or cigarette, etc.) to visualize flow patterns. 4. Seal leaks

Quantitative Blower Door How many points should you measure? How can you estimate uncertainty?

Test Data 1000 ft 2 house, 10 ft high ceilings Two-point test –1688 CFM at 51 Pa –1048 CFM at 24.5 Pa What is ACH 50 (λ 50 ), C?

Answers λ 50 = 1 ACH C = CFM/Pa n n = 0.65

Reporting blower door data Flow (or air exchange rate) at a given pressure Equivalent Leakage Area –What are dimensions of c?

Comment Blower doors do not measure air exchange rate –Why not? What do they measure?

40 Blower Door Misc. All windows and doors to outside closed –Why? What about buffer spaces? HVAC off Hard to do on windy days Watch out for buckling linoleum floors and fireplaces Flow direction change/ring change can be discontinuous Remember to record before and after reference pressures with fan covered 40

More Blower Door Tests Measure component leakage –What fraction of leakage is due to a certain component? –Tape off component and repeat test What are issues with this approach? Series leakage paths (AKA pressure diagnostics) –Air leaks to attic and then to crawlspace and then to outside

Residential Component Leakage ComponentRangeAverage Walls18-50%35% Ceilings Windows/Doors Fireplaces HVAC Other Vents2-125