Beam Profile Monitor Instrumentation in the Fermilab M-Test Beam

Slides:



Advertisements
Similar presentations
Triple-GEM detector operation for high-rate particle triggering W. Bonivento, G. Bencivenni, A. Cardini, C. Deplano, P. de Simone, F. Murtas, D. Pinci,
Advertisements

Plasma Window Options and Opportunities for Inertial Fusion Applications Leslie Bromberg Ady Herskovitch* MIT Plasma Science and Fusion Center ARIES meeting.
GEM Chambers at BNL The detector from CERN, can be configured with up to 4 GEMs The detector for pad readout and drift studies, 2 GEM maximum.
Prototype sPHENIX Calorimeters
Beam test of novel ASICs and sensors Marcin Chrząszcz Cracow University of Technology Itamar Levy Tel Aviv University.
Overview of Fermilab Accelerator Complex and Beam Lines T. Kobilarcik FNAL.
Machine Physics at ISIS Proton Meeting 24 th March 11 Dean Adams (On behalf of ISIS Accelerator Groups)
SNS Spallation Neutrino Source 1 SNS layout GeV proton linear accelerator Accumulator ring Main target Stripping foil.
CSC Test Beam Data Analysis Alexander Khodinov and Valeri Tcherniatine.
MTest Facility Low Energy Beam Erik Ramberg AEM 15 October, 2007.
Micromegas studies using cosmic rays Franck Sabatié May 7th 2009 Saclay cosmic ray bench Data acquisition system and analysis tools MIP detection Position.
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
Argonne Laser Test Stand and Fermilab Test Beam Facility Karen Byrum 8 March, 2007 Status of Argonne Laser Teststand (Joint ANL – UC program) Some first.
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
MC_ Muon Beam Lines 8/3/06 Want a  beam of ~300MeV/c –This requires a  beam of ~300 MeV/c Possible Sources: SY Proton Beam line components removed.
ILC Controls & Instrumentation R&D Activities at Fermilab G. Tassotto, M. Votava, M. Wendt Fermi National Accelerator Laboratory, Batavia, IL 60510, U.S.A.
Sept. 24, Status of GEM DHCAL Jae Yu For GEM-TGEM/DHCAL Group Sept. 24, 2010 CALICE Collaboration Meeting Univ. Hassan II, Casablanca Introduction.
Eric Prebys USPAS, Knoxville, TN, Jan , 2014.
Instrumentation Specifications July 26, 2001 S. Childress Page 1 NuMI Specifications for NuMI Primary Beam Instrumentation.
9/25/031 First Tests of an Optical Transition Radiation Detector for High-Intensity Proton Beams at FNAL September 25, 2003 Vic Scarpine.
Apex Target Marco Oriunno, April 23, Design and fabrication by: Marco Oriunno, Dieter Walz, Jim McDonald, Clive Field, Douglas Higginbotham, and.
LHCC, V0, Sept The V0 detector (Mexico Lyon collaboration)  Segmentation  Simulated performances secondaries / beam-gas  Counters design 1 /
A Fiber Profile Monitor for Low Beam Intensities * G. Tassotto †, H.Nguyen, G. Sellberg, D. Schoo, Fermi National Accelerator Laboratory, Batavia, IL 60510,
Neutron Structure Functions and a Radial Time Projection Chamber The Structure of the Neutron The BoNuS Experiment at CLAS A New Proton Recoil Detector.
NEW NEW Ionization Chamber Technology Anne Dabrowski Results on behalf of Mayda Velasco’s Hardware Research group. P. Ball 3, A. Darowski 1, G. Graham.
Status of the NO ν A Near Detector Prototype Timothy Kutnink Iowa State University For the NOvA Collaboration.
THE FORWARD PROTON DETECTOR AT DZERO Gilvan Alves Lafex/CBPF 1) MOTIVATION 2) DETECTOR OPTIONS 3) FPD R&D 4) OUTLOOK Lishep 98 Lafex/CBPF Feb 17, 1998.
AAC February 4-6, 2003 Protons on Target Ioanis Kourbanis MI/Beams.
Beam Instrumentation for Future High Intensity Hadron Accelerators at Fermilab Manfred Wendt Fermilab 8/25/2008HB2008 WG F: Diagnostics1.
V.Grishin, A.Koshelev, A.Larionov A.Pushkarev, V.Seleznev, M.Sleptsov A.Sytin.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Comissioning the NuMI Beam at Fermilab with Ion Chamber Arrays D. Indurthy, R. Keisler, S. Kopp, S. Mendoza, M. Proga, Z. Pavlovich, R. Zwaska Department.
C. Fischer – LHC Instrumentation Review – 19-20/11/2001 Gas Monitors for Transverse Distribution Studies in the LHC LHC Instrumentation Review Workshop.
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
The Meson Test Beam Facility Erik Ramberg LRP Meeting – Oct. 30,2003 Delivering MI beam to MTBF User area layout Operational characteristics Detectors.
G5 Beam Instrumentation D. Gassner, E. Pozdeyev 4-09.
Towards a 1m 3 Glass RPC HCAL prototype with multi-threshold readout M. Vander Donckt for the CALICE - SDHCAL group.
High Rate Tracking Test Beam Area David Christian & Richard Coleman.
LHC Beam Loss Monitors, B.Dehning 1/15 LHC Beam loss Monitors Loss monitor specifications Radiation tolerant Electronics Ionisation chamber development.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
UPDATE ON THE FORWARD PROTON DETECTOR Gilvan Alves Lafex/CBPF Introduction Accelerator Roman Pots Detector Future Plans April 1, 1998 (no kidding)
2002 LHC days in Split Sandra Horvat 08 – 12 October, Ruđer Bošković Institute, Zagreb Max-Planck-Institute for Physics, Munich Potential is here...
The BoNuS Detector: A Radial Time Projection Chamber for tracking Spectator Protons Howard Fenker, Jefferson Lab This work was partially supported by DOE.
Status and organization of the H8c area Mirko Berretti 08/07/2015 (with M.Bozzo, N.Minafra, E.Oliveri, X. Pons…)
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
NUMI Primary Beam Review August 14, 2001 NUMI PRIMARY BEAM INSTRUMENTATION Multiwires, Loss Monitors, Toroids Gianni Tassotto.
NuMI Hadron and Muon Monitoring Robert Zwaska University of Texas at Austin NBI 2003 November 10, 2003 Fermilab UTexas -- AustinUWisconsin.
SDHCAL. outline  SDHCAL concept, validation and construction  Test Beam and technological prototype performance  Perspectives and Conclusion  SDHCAL.
Beam on Target Diagnostics Beam on Target Meeting 2013 March Tom Shea.
AB/BI J. Koopman New WS design - Brain storm session 18/06/2007 1/16 New WS design - Brain storm session.
ESS wire scanner Benjamin Cheymol
Scintillating Fiber Profile Monitor The M-Test Experience Gianni Tassotto 112/15/2014.
Performances of a GEM-based TPC prototype for the AMADEUS experiment Outline: GEM-TPC in AMADEUS experiment; Prototype design & construction; GEM: principle.
NMLTA Protection System Update -Loss Monitors- Arden Warner September 2 nd, 2009.
PROFILE MONITORS FOR kW PROTON BEAM G. Tassotto, S. Childress, D. Jensen, D. Schoo Sept 24, 2014 NBI2014.
R. Arnold SLAC 24 June 2002 Real Photon Collaboration Conceptual Design Review Beam Monitoring Instruments.
Primary Design Parameters July 13,2001 S. Childress Page 1 NuMI Besides design specifications driven by physics and Main Injector beam parameters, significant.
The MiniBooNE Little Muon Counter Detector
Alexander Aleksandrov Spallation Neutron Source Oak Ridge, USA
FCAL R&D towards a prototype of very compact calorimeter
The Transition Radiation Detector for the PAMELA Experiment
From: A fast high-voltage switching multiwire proportional chamber
of secondary light ion beams
Beam Tests of Ionization Chambers for the NuMI Neutrino Beam Monitoring System MINOS.
C.Octavio Domínguez, Humberto Maury Cuna
Presentation transcript:

Beam Profile Monitor Instrumentation in the Fermilab M-Test Beam Gianni Tassotto, Wanda Newby, Rick Pierce, Linda Purcell-Taylor, Daniel Schoo, Greg Selberg, G. Tassotto TIPP-2011-Chicago

Fermilab Test Beam Facility The Site Fermilab Test Beam Facility G. Tassotto TIPP-2011-Chicago

Beam to M-Test Beam destined for M-Test via Switchyard is accelerated to 120 GeV in the Main Injector. It can be extracted in two ways: slow spill and single-turn extraction. Slow spill, currently the most common operational method, uses the QXR quadrupole circuit to resonantly extract beam over 1 second ( TEV event 20) or 4 seconds (TEV event 21). In single-turn extraction, beam is extracted with the MI-52 kicker/Lambertson combination. Switchyard begins in the Transfer Hall at F49, where the P3 line ends and the beamline branches away from the Tevatron to continue onwards through the Transfer Hall and eventually to M-Test Mode of Operation: Proton mode 120 GeV protons reach MT6 experiment Pion mode 8 to 66 GeV pion. Low energy pion mode where pion fluxes down to 1 GeV can be selected. G. Tassotto TIPP-2011-Chicago

M-Test Beam Layout Beam Test Facility M-Test beam G. Tassotto TIPP-2011-Chicago

M-Test Profile Monitors The energy range - 120 GeV down to 1 Gev at the experiment The beam intensity – from about 4x1011 ppp to a few thousand particles at the experiment All of the devices described below are interceptive and therefore cause beam losses. Multiwire/SEMs - Based on secondary emission phenomenon - Used in medium and high intensity beamlines SWICs - Segmented Wire Ion Chamber – Based on ionization - Middle and low intensity range PWCs - Proportional Wire Chamber - Ionization - low and very low intensity range SFPMs - Scintillation Fiber Profile Monitor - Very low intensity range G. Tassotto TIPP-2011-Chicago

Electronics FNAL uses the same electronics for all beamline profile monitors – designed by Al Franck Scanner has 48 integrating inputs in both X,Y planes Integration time is programmable from 5 μsec - 6.5 sec Trigger timing can use Tevatron clock events or a remote trigger The A/D for each plane processes +/- 10 volt signals. The amplifier is programmable for 1, 10 or 100 gain settings placed between the integrator outputs and the A/D inputs Noise  0.2% of full scale A calibration option is included to check for proper operation of all channels A network of scanners can be realized by connecting the scanners via Arcnet to a frontend which interfaces to the control systems Dynamic range – Scanner can display a minimum of around 5 pCoul. Depending on mode of operation, M-Test secondary beamline could have very low intensity. - a few 1000’s particles which translates to a few pCoul Typical minimum beam intensities: - SEMs  1010 particles - SWICs  104 particles - PWCs  103 particles - Fibers – first prototype a few thousand G. Tassotto TIPP-2011-Chicago

SEMs - 1 Medium to high beam intensity Located in the P1, P2 and P3 beamlines. These detectors have been made by first winding a 75 μm diameter AuW wire at 80 g of tension on a transfer frame, then, transferring the wind over the bare board, then soldering the wires on the pads on G-10 strips. Each paddle contains both a horizontal and a vertical set of 50 wires. No clearing field HV plane: 25 μm dia. AuW wire Limitations - Poor mechanical stability - Loss of wire tension - Poor vacuum due to G-10 G. Tassotto TIPP-2011-Chicago

SEMs - 2 New SEMs Ceramic substrate - “Flash test” option Kapton tape Bake assembly to over 100 C - Vacuum to 109 Torr Types: Cut-out to avoid insertion losses Figure 8 for lower residual losses - Ti substrate made by UTA with 5μm Ti strips Figure 8 Signal strength: Q = εNe where - ε secondary emission efficiency – around 3% - N is th number of particles through a wire - e is the electron charge 1.602 x 1019 Coul Programs that estimate the of the charge on a wire by knowing ε, the beam FWHM, and the wire diameters: 1012 ppp, FWHM=2 mm, 75 μm wire Q= 170 pF 1012 ppp, FWHM=6 mm, 50 μm wire Q= 37 pF or about 10 times above background Cut out Ti substrate G. Tassotto TIPP-2011-Chicago

SWICs Segmented Wire Ion Chamber Medium intensity beamlines, to 1012 ppp Chamber has a HV plane sandwitched between a X, Y plane Signal planes: wound 75 μm AuW wire at 80 g tension. Pitch 0.5 to 3 mm HV plane: 25 μm AuW wire wound at 20 g tension. Pitch 2 mm Gas: ArCO2 80/20 % Gas gain 105 at +2400 Volts Material in the beam: - (2) 3 mil Ti windows - (2) 3 mil Kapton windows - 1.25” ArCO2 gas Chamber design Complete Chamber Signal Planes Installed Assembly G. Tassotto TIPP-2011-Chicago

PWCs Proportional Wire Chamber. It enables us to display beam profiles down to a few thousand particles per pulse with background subtraction. Chamber Specifications Require vacuum break, typically 2 75 μm Ti windows Modular X,Y sense plane between HV foils Signal wires 12.5 μm AuW. These wires are fragile and an arc can break them. That’s why these chambers are modular Material: 60 m Al foils, 12.5 m diameter W, 2 cm gas Gas: Ar/Co2 at 80/20 % ratio Chamber Layout Completed chamber G. Tassotto TIPP-2011-Chicago

SFPMs -1 • Reduce beam losses of SWICs and PWCs M-Test beam energy range – 1-120 GeV Low beam intensity - down to a few ppp Detector Specifications: Fiber type – St. Gobain BCF-12MC Fibers are mated to 64 channel microchannel plate PMT for electron multiplication: Burle Planacom #85011-501 HV = -2300 (Gain = 800,000) Light output – 5 photo-electrons/MIP/fiber/ Detector Assembly: Set of 32 fibers/plane having Diameter 0.75 mm are epoxied to both sides of a ceramic board at a pitch of 2 mm. Fibers are bundled and epoxied into a vacuum feed-through called “cookie” that match the optical inputs of the Planacon PMT. Vacuum to 10-7 Torr – limited by the epoxy Tests showed noise overcame signal around 2000 particles with background subtraction. SFPM assembly SFPM in vacuum can G. Tassotto TIPP-2011-Chicago

SFPMs -2 New Design: Reduced length of scintillation fibers to beam active area Picture to the right shows assembly of fibers on ceramic substrate to cookie Picture below shows how the scintillation fibers are spliced to clear fibers using Bicron BC-600 optical grade epoxy Image below-right show light check raster scan of fibers with a light source G. Tassotto TIPP-2011-Chicago

SWIC/PWC/Fiber signal Display of SWIC starting in Switchyard, PWCs and Fibers downstream of target Beam on target E = 120 Gev, 2E11ppp - Secondary beam 32 GeV, 200,000 ppp G. Tassotto TIPP-2011-Chicago

Beam Losses Rick Coleman studied the transmission of the secondary beam and found that it gets degraded by the profile monitors and the air gaps The scintillation fibers of a SFPM intercept only 10 – 20 % , depending on spot size, of that of a scintillator paddle listed in the table By replacing all or even some of the SWICs and PWCs with SFPMs the quality of the beam would improve Type of Material Radiation Length (X0) Interaction Lengths () Air 0.055 0.022 17 Windows 0.049 0.007 Scintillator paddle 0.038 0.020 PWCs 0.036 0.008 Total 0.18 0.057 G. Tassotto TIPP-2011-Chicago

Conclusion Efforts continue to seek to improve the beam quality of the M-Test beamline by improving the detectors design to display low intensity beams while minimizing beam losses We are in the process of assembling an improved Scintillation Fiber Profile Detector that will enable us to display lower beam intensities Finally, for more information about the Beam Facility please click on: http://www-ppd.fnal.gov/FTBF/ G. Tassotto TIPP-2011-Chicago

MCT-PMT G. Tassotto TIPP-2011-Chicago