Control & Management Solutions

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

Remote Monitoring and Control System
Vehicle Tracking Remote Control & Monitoring System.
Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
What we do Larotecs Web2M is an off-the shelf, end-to-end, web-based solution designed to manage multiple widely distributed devices.
Transmitting & Receiving Contents  Hardware for Transmitting & Receiving:By Ryan Caulfield  Software for Transmitting & Receiving: By Todd John  Non-Computer.
G-Eye Extending your monitoring & control capabilities
EMS ROMC Environment monitoring system for ROMC..
POC Security System High security system combining PIN-on-Card, information security, physical access, control and alarm – all in one system.
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
Total HVAC Control from anywhere Easy control that can save a fortune
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Digital video security systems 2 Multi-functional CCTV Management System The Most Complete Integrated Digital CCTV Management System.
Remote Monitoring and Management Solutions ®
12-Port IP Power Manager IPM  Product Overview  Product Features  Applications  Comparison Presentation Outline 2 / 15.
Smart Guard of Your Data Storage EXAGATE monitors, manages and warns for you.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
REMOTE SITE MANAGEMENT SOLUTION. AGENDA 2  About KoçSistem  Current Situation in Base Stations  Remote Site Management System: Sitelink  Sitelink.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
©Kwan Sai Kit, All Rights Reserved Windows Small Business Server 2003 Features.
ACCOUNTABILITY shouldn’t mean working 24/7.
FOX AVL SYSTEM Satellite vehicle locating, tracking and fleet management.
Computer Emergency Notification System (CENS)
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
SECURITY. ANYWHERE, ANYTIME.. Mobeye team The company Mobeye is specialized in high quality GSM/GPRS alarm and telemetry technology. Mobeye products are.
NETWORKING FUNDAMENTALS. Network+ Guide to Networks, 4e2.
1 ARC reporting ARCCerny Verze INTERNET ARC events reporting Control panel 3. PSTN Telephone network - CID 1. GSM network – GPRS IP CID.
11111 Apollo Internet Monitoring Tutorial Apollo Solar, Inc. 23 F. J. Clarke Circle Bethel, CT (203)
Remote monitoring solutions to protect mission critical infrastructures Remote monitoring and control solutions to guard your mission-critical IT equipment.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
FLATPACK Rev.5 September 2002 Updated versions may be available.
Network and Server Basics. Learning Objectives After viewing this presentation, you will be able to: Understand the benefits of a client/server network.
Team Members: ECE- Wes Williams, Will Steiden, Josh Howard, Alan Jimenez Sponsor: Brad Luyster Honeywell Network Traffic Generator.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Poseidon 4002 Rack monitoring.
Frequently Asked Questions (FAQ)
Chapter 7. Identifying Assets and Activities to Be Protected
Avaya VA Line-interactive UPS
Case Study: Real Life Unified Architecture Value
ICON Signals Event Alert Notification Platform Overview March 28, 2017
COSEC ARC IP based Access Control Panel.
IP-based 8-port Switched Power Manager
Maintain, Manage And Monitor Outdoor Systems Remotely
BEST CLOUD COMPUTING PLATFORM Skype : mukesh.k.bansal.
SMS module HDL-MGSM.431.
Reveal™ Touch Screen Product Overview
Technology that lets you Trust your batteries!
Universal connection and monitoring for M2M applications
DS3 Fail-over Protection Switch
How SCADA Systems Work?.
Introduction to Computers
PowerValue 11 RT Sales Presentation
Programmable Logic Controllers (PLCs) An Overview.
PowerValue 11/31 T Sales Presentation
GSM door opener Model RTU5015 RTU5025 .Different appearance ,the same function.
STP Enhancements for z10 EC, z10 BC, z9 EC, z9 BC
ACS Webinar
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
ACOE347 – Data Acquisition and Automation Systems
Total HVAC Control from anywhere Easy control that can save a fortune
Integrated gateway-server
Simple, accurate tenant sub-metering
Villas, appartments, residence
Presentation transcript:

Control & Management Solutions July 2009

Control & Management There are various ways to control different equipment types and site conditions: Dry controls Measurements Environment Sensors / detectors Communication UPS and DC Systems 01:39

Older telecom equipment Equipment control Air Conditioners Older telecom equipment Access Manufacturing Generators 01:39

Equipment control Check status and control operation of air conditioners. Control industrial or custom process, like switching cooling fan on when internal street cabinet temperature gets too high. Control older UPS and DC systems through their dry contact connection controls. Check and operate generators using it’s control panel. Access (barrier, gate, door) control via SMS or calls, with access database. Remote control of all equipment by Internet or SMS. Automatic response actions for situation changes. Notifications on e-mail and/or SMS about all events. 01:39

Electricity measurement Special low voltage sensors KWH meters Frequency Special low voltage sensors Voltage Current 01:39

Electricity measurement Various electrical measurements are supported. High voltages require external transformer-less transducers that lower high voltages to <5v level. High AC voltages can be lowered to <5v level by external transformer as well. Direct isolated inputs for <60vDC and <40vAC are also available. Measurement Without adaptor With adaptor Adaptor type AC voltage (V) 0÷40 0÷450 Transducer DC voltage (V) ± 0÷60 ± 0÷450 AC current (A)   0÷100 Current transformer DC current 60mV measurement DC Shunt DC current (A) Hall sensor Frequency (Hz) 45÷65 (up to 40v) 45÷65 01:39

Environment and more Fuel level Humidity Temperature Gas 01:39

Environment and more Humidity and temperature sensors can be installed and monitored. Thresholds and hysteresis levels for alarms are configurable. Wide list of generic sensors can be connected and monitored as well, operating at 0÷5Vdc or 0÷60mVdc. Generic sensors include gas, fluid level in a tank, liquid flow, lighting, process control and more. 01:39

Process micro switch control Door/window detectors Sensors and detectors Smoke detectors Water detectors Process micro switch control Motion detectors Door/window detectors 01:39

Sensors and detectors Security alarms can be sent based on events generated by smoke, water, flame, intruder, and motion detectors. Any detector with dry contact indication can be connected. Auxiliary operation voltage might be required by some types of detectors. 01:39

IT Control 01:39 Servers Switches / Routers Network printers Workstations 01:39

IT Control Servers, workstations, routers, switches, network printers, hardware firewalls and spam filters, and any other device with Ethernet connection can all be controlled by the IT Control feature. Devices supporting SNMP (Simple Network Management Protocol) provide various status information: CPU load, hard drive space, physical and virtual memory, installed software, and list of running processes. Detailed information can be viewed remotely. Windows servers shutdown is integrated through free client software. Manual and automatic LAN wakeup function is implemented. 01:39

Other manufacturer’s UPS UPS and DC Systems Other manufacturer’s UPS PS1006 DC System Power+ Modular UPS µPS-SP Industrial UPS Small UPS systems 01:39

UPS and DC Systems Gamatronic UPS and DC Systems can be monitored through RS-232 serial communication port. Notifications and alarms can be sent on SMS, e-mail, dry contacts. Full information about UPS status and operation on the web interface. Remote control actions (shutdown, load on bypass…). Computers shutdown due to power failure or low battery condition. Computer wake up after power failure. Some other manufacturer’s UPS and DC Systems are supported. 01:39

Practical applications: DATACENTER Water was detected under the raised floor in unmanned computer room by water leakage detector. What can be automatically done to minimize the damage? Send SMS notification to relevant people Send shutdown signal to all servers Operate local audio alarm by means of dry contact Wait for emergency service 01:39

Practical applications: UNMANNED SITE Thousand of cellular sites consume power, need security system and environmental controls. Only for knowing electricity consumption, personnel is being sent to every site once a month. How to minimize overall cost? Management and Control unit is installed All site parameters are monitored and reported Emergency actions are programmed Site access can be controlled KWH meters power consumption is accessible remotely 01:39

Practical applications: ACCESS CONTROL Medium sized company has about 200 employees entering the underground parking every day. Electronic barrier controls entry. How to automate entry process without implementing expensive tag security system? C&M unit is installed inside the barrier mechanism Build internal database with employee’s phone numbers In front of the barrier, they just dial in from the mobile The gate will open by recognizing their phone number The phone call will not be answered by the unit, no cost since there was no conversation 01:39

Gamatronic C&M Solutions: WING WING is a simple cellular communication device. It is being installed on UPS and DC systems, and provides SMS alarms to the end user or control centers. On Power+ UPS, for example, the unit’s network board will automatically detect and start using the newly attached cellular modem for communication. Recipient's phone numbers are easily added through the user friendly web interface. 01:39

Gamatronic C&M Solutions: WING SIM card is required for GSM communication, such as SMS or GPRS 12vDC operating voltage can be taken either from Power+ System Controller auxiliary voltage connector for battery backup, or from a provided 12v AC/DC adaptor. SIM card is required for operation, quad-band GSM modem provides worldwide cell network coverage. Supported products: DC Power Systems: PS1006, PS2012, 1UDC+ UPS Systems: µPS-SP, MST, Power+, Power+ SA 01:39

Gamatronic C&M Solutions: G4 G4 is a sophisticated control and management solution that includes embedded software with web interface and wide list of equipment monitoring options. It can be installed as an added value for UPS or DC system, or just as a stand-alone site controller. Fully configurable and programmable interface makes this unit highly flexible to fit any site and application. Available in stand-alone or 19” rack mountable versions. 01:39

Gamatronic C&M Solutions: G4 Front panel includes: Network connection Extra RS-232 output (usually disabled) Indicators SIM card slot Reset buttons 01:39

Gamatronic C&M Solutions: G4 Temperature sensor: Rear panel includes: Dry input contacts Changeover dry output contacts Temperature sensors connector (adaptor board included) RS-232 serial communication port Cellular antenna connection 12vDC connection 01:39

Gamatronic C&M Solutions: G4 G4 operates with dry contacts and temperature measurements for environment and equipment control. It can also communicate with a power device through RS232 serial communication port, and monitor computer equipment via the IT Control (Ethernet connection). Connection Amount Remark Dry inputs 8 N.O. / N.C. programmable Dry outputs 4 Changeover (N.O. / COM. / N.C.) Temperature 5 One sensor is included with the unit RS-232 1 UPS / DC system comms., several protocols Ethernet Web / SNMP communication + IT Control 01:39

Gamatronic C&M Solutions: G4 web interface Configuration and programming of G4 is performed through web interface, no software is required: 01:39

Gamatronic C&M Solutions: G4 web interface IT Control monitors any equipment with IP address, and shows verbose information for SNMP-enabled devices: 01:39

Gamatronic C&M Solutions: G4 web interface Serial device configuration helps to access all supported types of equipment with auto-detect feature: 01:39

Gamatronic C&M Solutions: G4 web interface SMS notifications will be sent to specified cellular numbers, and according to the event type: 01:39

Gamatronic C&M Solutions: G4 web interface The G4 will also accept external control through SMS messaging and reply to the initiator: 01:39

Gamatronic C&M Solutions: G-Eye is the fully featured Site Manager. Monitoring and control options are extended compared with the G4. It also shows great emergency performance with it’s internal backup battery and front panel LCD. Complete site monitoring includes more features, like KWH meters and power measurements. Additional environmental control features include more options. 19” design to suit standard mounting equipment. 01:39

Gamatronic C&M Solutions: Connection Amount Remark Dry inputs 32 NO/NC programmable Dry outputs 16 Changeover Temperature 4 One sensor included RS-232 1 UPS / DC system monitoring Ethernet Communication + IT Control AC or DC volts / AC or DC amps 12 Transducer required > 40v/60vDC Isolated DC volts / DC amps Up to 60v or 60mV shunt Frequency 2 Transducer required > 40v kWH metering Pulse reading only Humidity Precise 0÷100% measurement Flood (with aux. voltage) Special sensors available Liquid level Various sensors exist on market 01:39

Gamatronic C&M Solutions: Servers Safety kWH Air conditioners Telecom equipment UPS Diesel generators DC Power Fuel level Measurements 01:39

Gamatronic C&M Solutions: With the G-Eye on the site, you receive the most complete data including live electricity measurements. All this without unnecessary complications and costs involved in installation and maintenance. All programming and fine tuning are performed remotely, without loosing the control even for a minute. Universal input power and the backup battery features will ensure that appropriate procedures will be executed and alarms sent even during total site blackout. Security is maintained by password protection on the web interface. No actions can be carried out without authentication. 01:39

Gamatronic C&M Solutions: G-Eye web interface G-Eye electricity measurements are highly configurable, all of them include high/low alarms and hysteresis. 01:39

Gamatronic C&M Solutions: G-Eye web interface All connected measurements must be calibrated carefully upon installation in order to achieve correct figures. 01:39

Gamatronic C&M Solutions: G-Eye web interface Internal log of events can be downloaded in MS Excel format for additional processing. 01:39

Gamatronic C&M Solutions: G-Eye web interface The complete configuration can be saved in a file and kept for backup, or used for configuring other units. 01:39

Gamatronic C&M Solutions: Management Software Control centers require global centralized control over large amount of units and/or sites. GEMSi software is designed for both large control centers and compact, in-company monitoring. Gamatronic Element Management System innovated 01:39

Gamatronic C&M Solutions: Management Software Secure user-controlled interface with action logging allows direct access to regions and sites, either on country/county or factory/room level. All Gamatronic and supported non-Gamatronic units can be put on one screen. Alarms pop up and logged for all units, with user-defined severity. Data logging is supported for detailed tracking of problematic site conditions. Unlimited event logging. Powerful, fully configurable reports generation supports excel output format. Database backup/restore feature. Includes all Gamatronic communication software. 01:39

Gamatronic C&M Solutions: Management Software Easy map oriented navigation makes control simple and intuitive. 01:39

Gamatronic C&M Solutions: Management Software Built in browser shows real-time data within GEMSi, without the need to open external windows. 01:39

Gamatronic hardware and software Control & Management solutions keep you confident and your site safe wherever you are at all times. 01:39