This program is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from Aqua Lung International. It may not be distributed through the internet or computer bulletin board systems without prior consent in writing from Aqua Lung International ©2007 Aqua Lung International, Inc. Legend Series First Stage Service Program Copyright notice
O-ring Removal (Pinch Method) P/n Pinch Method: Using fingers, push on opposite sides to create protrusion Use only brass or plastic pics to remove o-rings, this will protect delicate seating surfaces Never reuse o-rings
Product Features Go directly to Disassembly
Features Models Over-Balanced Diaphragm Design Dry Chamber (Environmentally Sealed) Air Turbo System Available In 300 Bar DIN Polyurethane Sheath
Features Easy Access To HP Seat Hose Configuration High Pressure Seat Conical Filter Nitrox Compatible
Features (Models) Five Models –Legend LX –Legend LX Supreme –Legend –Legend Supreme –Legend Glacia
Features (Diaphragm Mechanism) Proven high performance design Small components reduce friction compared to large piston Moving parts protected from environment Peak performance regardless of tank pressure or depth Easy to set the medium pressure externally
Features (Over-Balanced Design) Balanced First Stage –Medium pressure remains constant at 135 psi plus ambient Legend First Stage –Medium pressure increase at a rate faster than ambient –Increases by two atmospheres by 165 feet –Helps compensate for denser air at depth
Features (Dry Chamber) Protects main spring from freeze-up Keeps spring chamber free of contamination & corrosion No messy oil
Features (Air Turbo System) Shortcut between MP reservoir and diaphragm chamber Diaphragm reacts faster to pressure drop Reg becomes more responsive to air demand
Features (Yoke Or DIN) 3365 psi yoke (232 Bar) 4351 psi DIN (300 Bar)
Features (Polyurethane Sheath) Provides shock resistance Covers entire brass body Enhances cosmetics of first stage Replacement sheaths can dress up used regs
Features (Easy Access) End plug also balancing chamber Eliminates spring block and spring
Features (Hose Configuration) Can be mounted with diaphragm up or down Two HP ports for redundancy and versatility Four MP ports to accommodate drysuit hose
Features (High Pressure Seat) Best in industry! Operates up to 4500 psi Resilient to deep coining Forgiving of contaminants
Features (Conical Filter) More porous than previous filters Greater surface area –Better filtration –Better flow Same filter used in yoke or DIN configuration
Features (Nitrox Compatible) The Legend is nitrox (EAN) compatible to 40% out of the box Built with a high level of cleanliness EAN compatible components and lubricants Have passed required adiabatic compression testing to ensure their safety and compatibility
Features (Nitrox Compatible) Responsibility of the owner to maintain the cleanliness of the regulator If regulator will be used interchangeably with breathing air, the air should be oxygen-compatible or hyper- filtered whereas the condensed hydrocarbons do not exceed 0.1 mg/m3 Grade E air does not necessarily meet this criterion Hydrocarbons found in Grade E air can pose a risk in the presence of elevated oxygen content
Features (Nitrox Compatible) Hydrocarbons build up over time along the passageways of the equipment When hydrocarbons come in contact with high-pressure oxygen enriched air, they can pose a very real hazard that can lead to combustion If a regulator has had use with Grade E breathing air, it should receive a standard overhaul, including ultrasonic cleaning with a detergent solution, that removes hydrocarbons, prior to being put back into nitrox service
Features (Nitrox Compatible) Although second stage components are not exposed to high pressure EAN, Aqualung recommends that the same cleaning procedures be followed for the complete regulator This prevents the possibility of cross contamination and guarantees the cleanliness of the entire regulator
Disassembly
Remove One HP Port Plug 4mm hex key
Remove Cap 8mm hex key
Remove Ribbed Washer
Remove Secondary Diaphragm
Remove Piston
Remove Spacer
Remove Adjustment Screw 8mm hex key Remove washer
Remove Main Spring
Install Vise Mounting Tool Vise mounting tool (p/n ) CAUTION: If using a CO2 cartridge, use a HP adapter so threads dont break off in 1 st stage port ! Or discharged CO2 cartridge w/HP adapter
Remove Spring Retainer Install vise mount tool into bench vise –32mm wrench –17mm hex key for Glacia CAUTION: NEVER mount 1 st stage directly in vise !
Remove Spring Pad
Remove Thrust Washer NOTE: Pull thrust washer to one side and rotate
Remove Diaphragm Recommended method: –Keep finger over diaphragm –Use a quick blast of LP air –Alternate method to follow
Remove Pin Support & Pin
Remove HP Plug 8mm hex key
Remove HP Seat & Spring
NOTE: Pin will come out during this class because diaphragm is still installed
Remove Diaphragm (Alternate) Push out with seat extraction tool (p/n )
Remove HP Plug O-ring
Remove HP Plug O-ring & Backup Ring ! CAUTION: Care must be taken not to scratch the inside wall of the balance chamber or a leak could result
Remove Crown Orifice Work over padded surface –Use extraction tool –Insert tool at an angle
Remove Crown O-ring
Disassemble ACD Yoke (Auto-Closure Device) Click here Non-ACD Legend Click here Legend ACD (DIN)
Disassemble ACD (Yoke) Mount in vise –Remove yoke screw & dust cap –15 adj. wrench –Remove yoke retainer
Remove O-ring & Filter
Loosen Yoke Shutter Valve Install yoke retainer back into yoke –Install dust cap & yoke screw –Snug down yoke screw
Turn Clockwise Carefully clamp yoke retainer in vise by the wrench flats –Use 3mm hex key –Turn clockwise to loosen yoke shutter valve
Remove Yoke Screw Remove from vise –Remove yoke screw & dust cap
Remove ACD From Yoke Separate ACD components
Remove Shutter Valve O-ring Push shutter valve out of shutter crown Remove o-ring first
Remove Shutter Crown O-ring Remove o-ring from inside groove of shutter crown
Yoke ACD Components Click here move to next step
Disassemble ACD DIN Remove dust cap
Install DIN To Yoke Converter DIN to yoke converter (p/n )
Remove Shutter Valve Remove DIN shutter valve Secure 1 st stage into vise –4mm hex key NOTE: Early versions require a 3mm hex key
Remove DIN To Yoke Converter Remove shutter crown
Remove Shutter Crown O-rings
Remove Spring
Remove DIN Screw 7/16 or 11mm deep socket
Remove DIN Screw O-ring
Remove Handwheel
Remove Filter Holder 17mm wrench
Remove Filter & O-ring Seat extraction tool
DIN ACD Components
Disassemble Legend (Yoke) Mount in vise –Remove yoke screw & dust cap –15 adjustable wrench Click here Legend (DIN)
Remove C-clip & Filter Shield Reversible circlip pliers (p/n )
Remove Filter & O-ring Use blunt end of seat extraction tool Click here move to next step
Disassemble Legend (DIN) Mount in vise –Remove dust cap –6mm hex key –Remove DIN connector
Remove Handwheel
Remove DIN Connector Filter & O-ring seat extraction tool
Remove Face O-ring
Remove All Port Plugs Remove body from vise –Remove vise mounting tool –4mm hex key
Remove Sheath
This Concludes Disassembly
Cleaning & Lubrication Go directly to Reassembly
Cleaning Procedures Brass and Stainless Steel Parts –Pre-clean in warm soapy water; nylon bristle brush –Ultrasonically clean with soapy water; vinegar OK on tough corrosion –Rinse in fresh water; use distilled water if tap water is hard –Blow dry with hydrocarbon free gas (for EAN use)
Cleaning Procedures Aluminum, Plastic & Rubber Parts –Soak in warm, soapy water –Use soft nylon bristle brush to remove deposits –Rinse with fresh water –Blow dry with LP hydrocarbon free gas (for EAN use) CAUTION: DO NOT soak plastic parts in acidic solutions !
Cleaning Procedures Regulator Hose –Hose fittings - Ultrasonically clean with soapy water; vinegar OK on tough corrosion –Can run soapy water through hose if needed –Thoroughly rinse with fresh water –Blow out hose before installing
Lubrication Procedures Lubrication –Christo-lube MCG 111 –Light film only –Remove visible excess –If regulator will be used with EAN, you should wear powderless, latex gloves (or equivalent) when lubricating and handling o-rings
Reassembly
Install Sheath
Install Port Plugs 4mm hex key –Leave out 1 MP and 1 HP plug Install port plug o-rings
Inspect Crown Orifice Critically inspect the crown orifice under magnification –Confirm it is acceptable for reuse Sealing area O-ring groove
Install Crown O-ring
Install Crown Orifice Use seat installation tool –Place crown against plastic handle –Push crown into the body –Make sure crown is seated evenly
Install Backup Ring In HP Plug Concave side facing out; fits up against o-ring
Install HP O-ring
Install HP Plug O-ring
Install HP Seat & Spring
Install HP Plug 8mm hex key –Compress & turn simultaneously
Torque HP Plug 8mm hex key adapter –In/lb torque wrench –45 in/lbs (4.9 Nm) Torque: 45 in/lbs 4.9 Nm
Install Pin & Pin Support Press down several times, should feel spring loaded
Install Diaphragm & Thrust Washer Press edges to ensure its evenly seated Either side faces up –Press edges to ensure its evenly seated
Install Spring Pad Click here for Legend Glacia
Install Main Spring & Washer
Install Adjustment Screw 8mm hex key –Capture first few threads –DO NOT thread all the way in
Install Spring Retainer Main spring fits into adjustment screw
Torque Spring Retainer Install vise mount tool into body, mount in vise –Use Legend spring retainer socket (p/n ) & ft/lb torque wrench w/ 3 ext. –Torque to 18 ft/lbs (24.5 Nm) Optional: 32mm crow-foot Torque: 18 ft/lbs 24.5 Nm
Install Spring Retainer
Torque Spring Retainer Install vise mount tool into body, mount in vise –Use 17mm hex key adapter & ft/lb torque wrench –Torque to 18 ft/lbs (24.5 Nm) Torque: 18 ft/lbs 24.5 Nm
Install Main Spring & Washer
Install Adjustment Screw 8mm hex key –Capture first few threads –DO NOT thread all the way in
Preset Adjustment Screw 2-3 threads showing above inside rim
Assemble ACD Yoke (Auto-Closure Device) Click here Non-ACD Legend Click here Legend ACD (DIN)
Assemble ACD (Yoke) Install o-ring into shutter crown –Use seat installation tool to help guide o-ring
Shutter Valve Into Shutter Crown
Install Shutter Valve O-ring
Set Spring In Spring Retainer
Set Shutter Crown On Spring
Place Sub-Assembly In Yoke
Install Dust Cap & Yoke Screw Compress the spring by tightening the yoke screw until snug
Tighten Counter-Clockwise 3mm hex key –Tighten shutter valve counter- clockwise 3-full turns
Tighten Yoke Screw Snug
Tighten Counter-Clockwise Carefully clamp yoke retainer in vise by wrench flats –3mm hex key adapter and in/lb torque wrench –Torque to 18 in/lbs (2 Nm) Torque: 18 in/lbs 2 Nm
Remove Yoke Retainer
Measure Shoulder 1.5mm
Install Unlubricated O-ring & Filter
Assemble Legend (Yoke) Install filter shield –Flat side of C-clip faces upward Click here Legend (DIN)
Install Filter & O-ring Install unlubricated o-ring Insert conical end first
Install Inlet Fitting Pass inlet fitting thru yoke –Keep filter facing up; prevents o-ring from falling out
Torque Inlet Fitting Inlet socket (p/n ) –Ft/lb torque wrench & 3 extension –Torque to 18 ft/lbs (24.5 Nm) Torque: 18 ft/lbs 24.5 Nm
Install Yoke Screw Dust cap over threads w/Aqua Lung logo facing out –Remove 1 st stage from vise –Remove vise mount tool Click here move to next step
Assemble ACD (DIN)
Install O-rings In Shutter Crown Install unlubricated face o-ring
Install DIN Screw O-ring
Insert Filter Holder Into Handwheel
Install DIN Screw Thread DIN screw into filter holder –7/16 or 11mm deep socket –Tighten DIN screw hand-tight
Assemble ACD (DIN) Install filter Install unlubricated o-ring into filter holder
Install DIN Adapter Hold 1 st stage inlet side down –7/16 or 11mm deep socket –Thread DIN adapter up into body until snug
Torque DIN Screw Mount 1 st stage in bench vise –Ft/lb torque wrench & 7/16 or 11mm deep socket –Torque to 18 ft/lbs (24.5 Nm) Torque: 18 ft/lbs 24.5 Nm
Install Spring & DIN Crown
Install DIN To Yoke Converter
Insert DIN Shutter Valve
Torque DIN Shutter Valve In/lb torque wrench –4mm hex key adapter –Torque to 18 in/lbs (2 Nm) NOTE: Early versions require a 3mm hex key Torque: 18 in/lbs 2 Nm
Remove DIN To Yoke Converter Remove 1 st stage from vise –Remove vise mounting tool
Assemble Legend (DIN) Install unlubricated o-ring
Install Filter & Unlubricated O-ring
Install DIN Adapter Hold 1 st stage inlet side down –Thread DIN adapter up into body until snug by hand
Torque DIN Adapter Mount 1 st stage in bench vise –Ft/lb torque wrench –6mm hex key adapter –Torque to 18 ft/lbs (24.5 Nm) Torque: 18 ft/lbs 24.5 Nm
Adjusting & Final Assembly
Adjusting Medium Pressure (MP) Install MP gauge (p/n ) into 1 st stage MP port –If gauge lacks over-pressure relief valve, attach properly adjusted 2 nd stage as relief valve in case of HP leak
Adjusting Medium Pressure (MP) Attach Legend to fully charged cylinder 3000 psi (206 bar)
WARNING ! If the pressure gauge rapidly exceeds 145 psi (10 bar), there is a HP leak. Quickly close the cylinder valve and purge the regulator. Failure to do so may cause a rupture to the MP hose and/or MP gauge which, in turn, can lead to personal injury
Adjusting Medium Pressure (MP) With relief valve open on gauge, slowly open cyl. valve & pressurize the 1 st stage
Adjusting Medium Pressure (MP) Close the relief valve –If MP rapidly exceeds 145 psi (10 bar ), open relief valve & shut off cylinder valve –This means there is a HP leak
Adjusting Medium Pressure (MP) Using an 8mm hex key –Turn adjustment screw clockwise in 1/8 turn increments to increase the MP –Turn Adjustment screw counter- clockwise to decrease the MP
Adjusting Medium Pressure (MP) Using the relief valve on the gauge –Cycle the reg several times after each adjustment –Set the MP to: Legend Std psi (9-10 bar) –Legend Supreme psi (8-9 bar) Legend Std. MP Settings: psi 9-10 bar Legend Sup. MP Settings: psi 8-9 bar
Adjusting Medium Pressure (MP) Let the regulator stand for several minutes. Check that MP remains stable –If MP rises more than 5psi (0.3 bar), it indicates a leak –Close valve, purge line & pressurize again – Confirm MP is stable Legend Std. MP Settings: psi 9-10 bar Legend Sup. MP Settings: psi 8-9 bar
Install Spacer & Ribbed Washer Spacer flats face upward, align flats w/spring retainer flats
Install Piston (Load Transmitter) Dry chamber parts must be installed while under pressure
Install Diaphragm Cup side faces down –Diaphragm edge fits into outer groove –Work edges with finger
Torque Cap Mount 1 st stage in bench vise –In/lb torque wrench –8mm hex key adapter –Torque to 35 in/lbs (3.9 Nm) Torque: 35 in/lbs 3.9 Nm
Testing
Recheck MP MP should still be in proper range – psi for Std. (9-10 bar) – psi for Supreme (8-9 bar) –Readjust if necessary Legend Std. MP Settings: psi 9-10 bar Legend Sup. MP Settings: psi 8-9 bar
Immersion Test With Legend still pressurized –Submerge in bath of water –Look for streaming bubbles; dont mistake trapped air for leaks –Note leak source; refer to troubleshooting table in Technical Maintenance Manual
This Concludes Service Of Legend 1 st Stage Rev 07/10/07