Delayed cardiac tamponade by iatrogenic aortic perforation with pacemaker implantation Charles C. Sticco, DO, Leonard O. Barrett, MD The Journal of Thoracic and Cardiovascular Surgery Volume 131, Issue 2, Pages 480-481 (February 2006) DOI: 10.1016/j.jtcvs.2005.08.060 Copyright © 2006 The American Association for Thoracic Surgery Terms and Conditions
Figure 1 Transthoracic echocardiogram illustrating collapse of Right Ventricle, Left Ventricle and Pericardial Fluid surrounding myocardium. The Journal of Thoracic and Cardiovascular Surgery 2006 131, 480-481DOI: (10.1016/j.jtcvs.2005.08.060) Copyright © 2006 The American Association for Thoracic Surgery Terms and Conditions
Figure 2 Transthoracic echocardiogram doppler illustrating Tricuspid Valve flow velocity variation with respiration. The Journal of Thoracic and Cardiovascular Surgery 2006 131, 480-481DOI: (10.1016/j.jtcvs.2005.08.060) Copyright © 2006 The American Association for Thoracic Surgery Terms and Conditions