Satish C. Muluk, MD, David A. Vorp, PhD, Donald A

Slides:



Advertisements
Similar presentations
Endothelial cell seeding reduces thrombogenicity of Dacron grafts in humans Per Örtenwall, MD, PhD *, Hans Wadenvik, MD, PhD **, Jack Kutti, MD, PhD **,
Advertisements

The role of arteriovenous shunts in the pathogenesis of varicose veins Howard C. Baron, M.D., Sebastiano Cassaro, M.D. Journal of Vascular Surgery Volume.
The effect of inguinal lymphatic manipulation on regional lymph flow patterns Jeffrey R. Rubin, MD, Lisa B. Eberlin, MD Journal of Vascular Surgery Volume.
A review of 100 consecutive reconstructions of the distal vertebral artery for embolic and hemodynamic disease  Ramon Berguer, MD, PhD, Mark D. Morasch,
Popliteal artery stenosis caused by a Baker's cyst
Christopher A. DeMaioribus, MD, Charles A. Anderson, MD, Sandy S. G
Matthew R. Quigley, M. D. , Julian E. Bailes, M. D. , Hau C. Kwaan, M
Daniel J. Lindner, M. D. , James M. Edwards, M. D. , Edward S
Axillary-to-carotid artery bypass grafting for symptomatic severe common carotid artery occlusive disease  Joseph P. Archie, PhD, MD  Journal of Vascular.
Ultrasound measurement of the luminal diameter of the abdominal aorta and iliac arteries in patients without vascular disease  Ole Martin Pedersen, MD,
Mark F. Fillinger, MD, Emanuel R. Reinitz, MD, Robert A
Robert J. Pitsch, MD, David J. Minion, MD, Margaret L
In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization.
Effect of a femoral arteriovenous fistula on lower extremity venous hemodynamics after femorocaval reconstruction  Sunil S. Menawat, MD, Peter Gloviczki,
Creation and closure of temporary arteriovenous fistulas for venous reconstruction or thrombectomy: Description of technique  Richard J. Sanders, M.D.,
Mycotic axillary artery aneurysm
A new valvulotome for in situ bypass grafts
Walter J. Scott, M.D., Bruce L. Gewertz, M.D. 
Ambulatory venous pressure revisited
Effect of retroviral transduction on human endothelial cell phenotype and adhesion to Dacron vascular grafts  Ronald J. Jankowski, MS, Donald A. Severyn,
Malcolm O. Perry, MD, Richard Kempczinski, MD 
Laura Garvey, MD, Michel S. Makaroun, MD, Visala S
Protecting the brain and spinal cord
Adventitial cystic disease of the popliteal artery: Failure of percutaneous transluminal angioplasty as a therapeutic modality  Robert L. Fox, M.D., Mark.
L. J. Downing, MD, T. W. Wakefield, MD, R. M. Strieter, MD, M. R
Daniel J. Lindner, M. D. , James M. Edwards, M. D. , Edward S
Limited B-mode venous imaging versus complete color-flow duplex venous scanning for detection of proximal deep venous thrombosis  Roberta Poppiti, BS,
Objective tinnitus resulting from internal carotid artery stenosis
Refinements in the ultrasonic detection of popliteal vein reflux
Vein compression by arterial aneurysms
Transarterial wall oxygen gradients at a prosthetic vascular graft to artery anastomosis in the rabbit  Steven M. Santilli, MD, PhD, Shane E. Wernsing,
Does the end-to-end venous anastomosis offer a functional advantage over the end-to- side venous anastomosis in high-output arteriovenous grafts?  Mark.
Angioscope-assisted occlusion of venous tributaries with prolamine in in situ femoropopliteal bypass: Preliminary results of canine experiments  John.
Boulos Toursarkissian, MD, David Schwartz, MD, PhD, Paul R
A. N. Nicolaides, MS, FRCS, M. K. Hussein, MD, FRCS, G. Szendro, MD, D
William C. Pevec, MD, Douglas Hendricks, MD, Marc S
Calvin B. Ernst, MD  Journal of Vascular Surgery 
Provoked compliance of the supernormal popliteal vein
An improved retraction system for vascular surgical procedures
James R. Burnett, MB, BS, FRACS, Robert J. Lusby, MD, FRCS, FRACS 
Mesenteric venous thrombosis
Miltos K. Lazarides, MD, Spyros N
Cardiovascular surgery—The rocket and its stars: Presidential address
Preoperative noninvasive assessment of arm veins to be used as bypass grafts in the lower extremities  Sergio X. Salles-Cunha, Ph.D., George Andros, M.D.,
The fate of the donor artery in extraanatomic revascularization
Composite sequential bypasses to the ankle and beyond for limb salvage
Ambulatory venous pressure revisited
Research and research funding in vascular surgery
Regarding “Venous ulcers and the superficial venous system”
James E. Edwards, MD, Lloyd M. Taylor, MD, John M. Porter, MD 
Seizures following subclavian-carotid bypass
Jay B. Fisher, MD, Marc A. Granson, MD  Journal of Vascular Surgery 
Carotid biaxillary bypass: A new operation
Cells derived from omental fat tissue and used for seeding vascular prostheses are not endothelial in origin  Michel J.T. Visser, MD, J.Hajo van Bockel,
Kim J. Hodgson, M.D., David S. Sumner, M.D. 
Repair of incompetent venous valves: A new technique
The effects of endothelial injury on smooth muscle cell proliferation
Glenn C. Hunter, M.D., Stan N. Carson, M.D. 
Salvage of exposed arteriovenous hemodialysis fistulas
Surgical management of refractory venous stasis ulceration
Homologous veins as an arterial substitute: Long-term results
Recognition and treatment of arterial insufficiency from Cafergot
Presidential address: The second-generation vascular surgeon
George D. Lilly 1906–1988 Journal of Vascular Surgery
James A. DeWeese, MD  Journal of Vascular Surgery 
Axillary-to-carotid artery bypass grafting for symptomatic severe common carotid artery occlusive disease  Joseph P. Archie, PhD, MD  Journal of Vascular.
Popliteal entrapment syndrome: A report of tibial nerve entrapment
Endovascular repair of two abdominal aortic aneurysms
Optimal proximal anastomosis/tunnel for axillofemoral grafts
Splenic infarction after splenorenal arterial bypass
Presentation transcript:

Enhancement of tissue factor expression by vein segments exposed to coronary arterial hemodynamics  Satish C. Muluk, MD, David A. Vorp, PhD, Donald A. Severyn, MS, Susan Gleixner, BS, Peter C. Johnson, MD, Marshall W. Webster, MD  Journal of Vascular Surgery  Volume 27, Issue 3, Pages 521-527 (March 1998) DOI: 10.1016/S0741-5214(98)70327-1 Copyright © 1998 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 1 Schematic of perfusion apparatus. For clarity, the pumps and the pulse duplicator apparatus are not shown. The specimen is housed inside a sterile chamber, which contains oxygenated and temperature-controlled media. The motors, carriage, and bellows are used only for coronary graft (CAVG) simulation. PP, Proximal pressure; DP, distal pressure; FG, frame grabber; MC, motion controller; A/D, analog/digital board. Journal of Vascular Surgery 1998 27, 521-527DOI: (10.1016/S0741-5214(98)70327-1) Copyright © 1998 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions

Fig. 2 Results of tissue factor (TF) immunohistochemical staining (original magnification, ×100) of vein segments from one experiment with HSV. A, Segment perfused under coronary artery conditions (CAVG). C, Segment perfused under venous (VEN) conditions. The upper and lower sets of panels differ only with respect to the peroxidase substrate used for staining (VIP and SG are the names assigned to these products). Horizontal arrows, positive staining on luminal side; vertical arrows, positive staining on adventitial side. Journal of Vascular Surgery 1998 27, 521-527DOI: (10.1016/S0741-5214(98)70327-1) Copyright © 1998 Society for Vascular Surgery and International Society for Cardiovascular Surgery, North American Chapter Terms and Conditions