CECOM LAR Operation Course

Slides:



Advertisements
Similar presentations
Hardware Integration of the Prototype Wes Grammer NRAO September 24-26, 2012EOVSA Prototype Review1.
Advertisements

Chapter Six: Receivers
HARP-B Local Oscillator
Modem Technologies ADSL Modem
 Like a server cabinet  The BTS3012 cabinet is purple gray in color and vertical in appearance.
Technician License Course Chapter 3 Types of Radios and Radio Circuits Module 7.
Wireless MODEM for 950 MHz Digital Communication
Department of Electronic Engineering City University of Hong Kong EE3900 Computer Networks Transmission Media Slide 1 Overview Guided - wire Unguided -
Integrated Circuits Design for Applications in Communications Dr. Charles Surya Department of Electronic and Information Engineering DE636  6220
Technician License Course Chapter 3 Types of Radios and Radio Circuits Module 7.
IT-101 Section 001 Lecture #15 Introduction to Information Technology.
King Saud University College of Applied studies and Community Service 1301CT By: Nour Alhariqi 1nalhareqi st semester
Technician License Course Chapter 3 Lesson Plan Module 7 – Types of Radio Circuits.
Electricity, Electronics And Ham Radio “Kopertroniks” By Nick Guydosh 4/12/07.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
All rights reserved © 2010, Mobiserve Prepared By: RIZWAN AHMED RAFIQ Operation Support Engineer (Training & Consultancy) ALCATEL BTS.
COMMUNICATION SYSTEM EEEB453 Chapter 7(Part I) MULTIPLEXING.
Technician License Course Chapter 3 Types of Radios and Radio Circuits Module 7 Presented by: The Brookhaven National Laboratory Amateur Radio Club Instructor:
1 ELE5 COMMUNICATIONS SYSTEMS REVISION NOTES. 2 Generalised System.
DATA TRANSMISSION AND RETRIEVAL This Chapter includes 1.Demodulation 2.Data Transmission and Retrieval 3.FAX 4.Modem.
Codan 5700 Series C-Band Transceiver Technical Overview.
Introduction to Communication Lecture (07) 1. Bandwidth utilization Bandwidth utilization is the wise use of available bandwidth to achieve specific goals.
Chapter4 Transmitter and Receiver Applications AM and FM Radios
1. Students will understand the function of the equipment associated with a closed circuit TV system. 2. Students will understand the function and purpose.
Chapter 6 Long Distance Communication. Long-Distance Communication Important fact: an oscillating signal travels farther than direct current For long-distance.
IT-101 Section 001 Lecture #15 Introduction to Information Technology.
CHAPTER 3 Physical Layer.
Maker 7660: Not Your Grandpa’s Ham Radio!
EARTH SEGMENT & SPACE LINK
MODEMS (Converts analog signals to digital and vice-versa)
Power Point presentation on DTH
Redundancy Switching Components
Introduction to electronic communication systems
Overview Communication is the transfer of information from one place to another. This should be done - as efficiently as possible - with as much fidelity/reliability.
21 September 2018 Project IEEE: Networks (WPANs) IEEE P Working Group for Wireless Personal Area Submission Title: [Multi-gigabit wireless demonstration.
DATA TRANSMISSION AND RETRIEVAL
Long-Distance Communication (Carriers, Modulation, And Modems)
Lecture 4 Continuation of transmission basics Chapter 3, pages 75-96
COMMUNICATION SYSTEMS
Chapter Five: Transmitters
DATA TRANSMISSION AND RETRIEVAL
Unit 2 Introduction to the AN/TRC-170
Chapter 2 Transmission Basics.
Lecture 8: Modems (Converts analog signals to digital and vice-versa) 1nd semester By: Adal ALashban.
Data Communication.
CH-6 CABLE TV.
Chapter 8 Circuit Switching and Telephone Network
CECOM LAR Tropo Operation Course
CECOM LAR Tropo Operation Course
Instructor Lesson Plan Unit 6 System End-to-End
AM-7027 Up Converter-Amplifier
AM-7026 Down Converter-Receiver
CECOM LAR Tropo Operation Course
AC POWER REQUIREMENTS & AC TO AC CONVERTER
Welcome to “TRC-170” Training
SN-553 Frequency Synthesizer
CECOM LAR Operation Course
CECOM LAR Operation Course
CECOM LAR Tropo Operation Course
TD-1236 Trunk Group Multiplexer
Basics of Telecommunications and Networks
ORDERWIRES CECOM LAR Course CONUS Branch FT McPherson, GA.
communications system
TD-1235 Loop Group Multiplexer
Technician License Course Chapter 3
AN/TRC-170 COMSEC Devices
CECOM LAR Operation Course
The Physical Layer Chapters
Student Studyguide Unit 3 Major Systems and Functions
Presentation transcript:

CECOM LAR Operation Course AN/TRC-170 SIGNAL FLOW CECOM LAR Course Logistics Assistance Division Fort Monmouth, New Jersey This is a critical part of this class. Understanding the flow will help you in the operation and troubleshooting the AN/TRC-170. Signal Flow

CECOM LAR Operation Course V2 SEP Location The AN/TRC-170(V)2 /3 has two Signal Entry Panels (SEP). The signal entry panels are the way we interface with the local subscribers. The SEP in both versions of the terminals are identical. However they are in different locations. Here we see the V2 SEP 1 & 2 SEP #1 is located on the bottom as shown in your LAR Handbook on page 4-2 SEP #2 is located on the top. Signal Flow

CECOM LAR Operation Course V3 SEP Location Here we see the curbside of the V3 TRC-170. SEP #1 is located on the right, closest to the door of the shelter. SEP #2 is located on the left, nearest the front of the shelter. Signal Flow

CECOM LAR Operation Course Signal Entry Panel 1 SEP-1 GM-1 Connects to CX-11230 Coaxial cable and to the right of it there is a surge protector assembly labeled GM-1. GM-2 Connects to CX-11230 Coaxial cable and to the right of it there is a surge protector assembly labeled GM-2. LGM-1 Can handle 16, 4 wire subscribers, digital or analogue, which can be brought in via 16 sets of quad push binding post that have surge protectors attached: or the 26 pair cable can support the first 13 subscribers. Subscribers 14 through 16 must be brought in through the binding post. Signal Flow

CECOM LAR Operation Course Signal Entry Panel 2 SEP-2 GM-3 Connects to CX-11230 Coaxial cable and to the right of it there is a surge protector assembly labeled GM-3. GM-4/LSCDM Connects to CX-11230 Coaxial cable, and to the right of it there is a surge protector assembly labeled GM-4/LSCD. NOTE the surge protector must be changed if the LSCDM is used. LGM-2 Can handle 16, 4 wire subscribers, digital or analogue, which can be brought in via 16 sets of quad push binding post that have surge protectors attached: or the 26 pair cable can support the first 13 subscribers. Subscribers 14 through 16 must be brought in through the binding post. ROCU- Two sets of quad binding post are also provided for connection of the ROCU. Signal Flow

CECOM LAR Operation Course V2 Block Diagram Now lets take a look at the Signal Flow of the AN/TRC-170V)2. Please refer to FO 4-1. Follow Signal Flow Multiplexer TD-1235 (LGM) 6A2, 6A5. The two Loop Group Multiplexer will multiplex up to 16 four wire, 16 or 32 KB/s conditioned diphase digital, or voice frequency analog inputs into one balanced NRZ digital group on the equipment side.   Digital data Modem MD-1026 (GM) 6A3. The main purpose of the GM is to change the cable format to a balanced NRZ signal and vice versa. It contains 4 separate pairs of Group Modem cards. These are referred to as GM 1 through 4. In addition to mission traffic, each individual group of the diphase GM interfaces a 2 KB/s data orderwire (DOW) and a 16 KB/s digital voice orderwire (DVOW) or an analog voice orderwire (AVOW). Cable Driver Modem TD-1023 (LSCDM) 6A5. The Low Speed Cable Driver Modem (LSCDM) interfaces a repeated CX-11230 coax cable system on the cable side with the AN/TRC-170 system on the equipment side. The optional equipment is not installed in any Army TRC-170 and will not be discussed. Baseband Patch Panel 6A1. The Baseband patch Panel is used to interface the DGM gear and the Tropo Modem.   Signal Flow

CECOM LAR Operation Course V2 Block Diagram Multiplexer TD-1236 (TGM) 6A4. The Trunk Group Multiplexer (TGM) multiplexes up to 4 data groups into 1 super group. The TGM is capable of controlling a TSEC/KG-94A Trunk Encryption Device (TED) on both the group and super group side. Trunk Encryption Device TSEC/KG-94A (TED). The TED performs full encryption/decryption of group or super group mission traffic. One or two TEDs are used, as required. TED 1 (5A1A1) is used on the radio (super group) side while TED 2 (5A1A2) is used on the cable (group) side. 2 KB/s DOW- Coming out of each GM you will notice a 2 KB/s DOW. This orderwire is only used by the Air Force. We will discuss it very briefly. The DOW is extracted and patched to the 7A1 Level converter. The level converter changes the level of the signal required for the KG-84. The signal is then sent to the DLED (KG-84) it is unencrypted and sent to the CESE. The CESE adds the status of the local terminal and sends it to the next DLED. There it is encrypted and sent back to the 7A1 level converter. Here the levels are changed back to the requirements for the Tropo Modem. 16 KB/s DVOW- A 16 KB/s is received by the GM and with the exception of GM-4 is routed directly to the 7A3 TOCU. Here the signaling and voice traffic is processed. Secure voice is provided by the KY-58. These orderwire signals are routed to the Tropo Modem for transmission. Signal Flow

CECOM LAR Operation Course V2 Block Diagram AVOW- The TRC-170 has the capabilities for a non-secure Analog Voice Orderwire. This is only sent across the cable side of the system. This used to talked to cable repairmen and to the TD-1234 (RMC). Demodulator-Modulator Group OM-71 (Tropo Modem). The TM has two sections, a Modulator and Demodulator. We will first discuss the 5A3 Modulator 5A3 section. The Tropo Modem takes the 2 orderwire signals and the super group data and multiplexes it onto one data stream. This data stream is then modulated unto a nominal 70 MHz IF and sent to the two up converters.The TM sends a Modulated 70 MHz signal out to the 7A5 IF Test Panel for internal loop back testing. The TM also sends two 10 MHz Reference signals to the Frequency Synthesizers.  Frequency Synthesizer 5A4 & 5A5. The synthesizer provides stable outputs in the 4.47 to 5.07 GHz ranges. These outputs supply local oscillator signals to the two Up Converters and two Down Converters. The synthesizer is phased locked to the 10 MHz signal from the Tropo Modem. Transmitter Amplifier-Converter AM-7027 (Up Converter). The Up Converter mixes the nominal 70 MHz IF with 4.47 to 5.07 GHz from the Synthesizer to produce the 4.4 to 5.0 GHz output signal. The converter has tow modes of operation, LOS and Tropo.  Signal Flow

CECOM LAR Operation Course V2 Block Diagram RF Amplifier (HPA). In the LOS mode of operation, the signal from the Up converter is routed through a filter in the HPA and no amplification is performed. In the Tropo mode the signal is routed through a 5 cavity klystron. There the signal is amplified and routed to the diplexer. kW, air cooled amplifier. It operates in the 4.4 to 5.0 GHz band. The klystron and High Voltage Power Supply is not used when operating in the LOS mode. Diplexer. This device is used in the V2 terminal only. It enables the transmitter and receiver to operate from a common antenna port. Waveguide Entry Panel- This panel on located on the outside of the shelter. Here we connect the four external wave guides which connect to the antenna. Antenna- The V2 uses two 9.5 foot parabolic antennas. Signal Flow

V2 Waveguide Entry Panel CECOM LAR Operation Course V2 Waveguide Entry Panel Wave guide Entry Panel #1 (Shown on the left, three ports) ECCM The top port is not used. It was intended to be used with a ECCM (Electronic Counter-Counter measure up grade. XMT/RCVR 1 Is located on the left. This connected the HPA #1 and Down Converter Receiver #1. RCV-4 Is located on the right of Entry Panel #1. This a receive only port and is connected to Down Converter Receiver #4. Waveguide Entry #2(Shown on the right, two ports) XMT/RCV 2 Is located on the right side. This connected to HPA #2 and Down Converter Receiver #2. RCV-3 Located on the left side of Wave guide entry Panel #2. This is a receive only port and is connected to Down Converter Receiver #3. Signal Flow

CECOM LAR Operation Course V2 Block Diagram Receiver Amplifier Converter AM-7026 (Down Converter). The Down Converters contain a LNA and a mixer which converts the 4.4 to 5.0 GHz to a 70 MHz IF. Two Down Converters are used for space diversity and two for frequency diversity reception. IF Test Panel 7A5. The IF Test Panel contains a loop back circuit and an antenna alinement circuit. The loop back circuit provides a calibrated means of applying the Tropo Modem modulator IF output to any one or any combination of Tropo Modem demodulator inputs. Tropo Modem-Demodulator 5A6. The demodulator performs the inverse function of the modulator. Specifically, it recovers the Baseband data from the 4 receiver IF inputs. Orderwire Control Unit C-10602 (VOCU) 7A3. The Voice Orderwire Control Unit (VOCU) provides a means of interfacing a VINSON, KY-58 secure voice instrument, with the 16 KB/s/s Digital Voice Orderwire. The connection is made on first come first served party line basis.   Signal Flow

CECOM LAR Operation Course V2 Rack Layout Point out locations of the equipment discussed Signal Flow

CECOM LAR Operation Course V3 Block Diagram Now let’s take a look at the Signal Flow of the AN/TRC-170V)2. Please refer to FO 4-1. Follow Signal Flow Multiplexer TD-1235 (LGM) 6A2, 6A5. The two Loop Group Multiplexers will multiplex up to 16 four wire, 16 or 32 KB/s conditioned diphase digital, or voice frequency analog inputs into one balanced NRZ digital group on the equipment side.   Digital data Modem MD-1026 (GM) 6A3. The main purpose of the GM is to change the cable format to a balanced NRZ signal and vice versa. It contains 4 separate pairs of Group Modem cards. These are referred to as GM 1 through 4. In addition to mission traffic, each individual group of the diphase GM interfaces a 2 KB/s data orderwire (DOW) and a 16 KB/s digital voice orderwire (DVOW) or an analog voice orderwire (AVOW). Cable Driver Modem TD-1023 (LSCDM) 6A5. The Low Speed Cable Driver Modem (LSCDM) interfaces a repeated CX-11230 coax cable system on the cable side with the AN/TRC-170 system on the equipment side. The optional equipment is not installed in any Army TRC-170 and will not be discussed. Baseband Patch Panel 6A1. The Baseband patch Panel is used to interface the DGM gear and the Tropo Modem.   Signal Flow

CECOM LAR Operation Course V3 Block Diagram Multiplexer TD-1236 (TGM) 6A4. The Trunk Group Multiplexer (TGM) multiplexes up to 4 data groups into 1 super group. The TGM is capable of controlling a TSEC/KG-94A Trunk Encryption Device (TED) on both the group and super group side. Trunk Encryption Device TSEC/KG-94A (TED). The TED performs full encryption/decryption of group or super group mission traffic. One or two TEDs are used, as required. TED 1 (5A1A1) is used on the radio (super group) side while TED 2 (5A1A2) is used on the cable (group) side. 2 KB/s DOW- Coming out of each GM you will notice a 2 KB/s DOW. This orderwire is only used by the Air Force. We will discuss it very briefly. The DOW is extracted and patched to the 7A1 Level converter. The level converter changes the level of the signal required for the KG-84. The signal is then sent to the DLED (KG-84) it is unencrypted and sent to the CESE. The CESE adds the status of the local terminal and sends it to the next DLED. There it is encrypted and sent back to the 7A1 level converter. Here the levels are changed back to the requirements for the Tropo Modem. 16 KB/s DVOW- A 16 KB/s is received by the GM and with the exception of GM-4 is routed directly to the 7A3 TOCU. Here the signaling and voice traffic is processed. Secure voice is provided by the KY-58. These orderwire signals are routed to the Tropo Modem for transmission. Signal Flow

CECOM LAR Operation Course V3 Block Diagram AVOW- The TRC-170 has the capabilities for a non-secure Analog Voice Orderwire. This is only sent across the cable side of the system. This used to talk to cable repairmen and to the TD-1234 (RMC). Demodulator-Modulator Group OM-71 (Tropo Modem). The TM has two sections, a Modulator and demodulator. We will first discuss the 5A3 Modulator 5A3 section. The Tropo Modem takes the 2 orderwire signals and the super group data and multiplexes it into one data stream. This data stream is then modulated unto a nominal 70 MHz IF and sent to the up converter.The TM sends a Modulated 70 MHz signal out to the 5A4 IF Test Panel for internal loop back testing. The TM also a 10 MHz Reference signal to the Frequency Synthesizer.  Frequency Synthesizer 3A2. The synthesizer provides stable outputs in the 4.47 to 5.07 GHz ranges. These outputs supply local oscillator signals to the Up Converter and two Down Converters. The synthesizer is phase locked to the 10 MHz signal from the Tropo Modem. Transmitter Amplifier-Converter AM-7027 (Up Converter). The Up Converter mixes the nominal 70 MHz IF with 4.47 to 5.07 GHz from the Synthesizer to produce the 4.4 to 5.0 GHz output signal. The converter has two modes of operation, LOS and Tropo.  Signal Flow

CECOM LAR Operation Course V3 Block Diagram RF Amplifier (HPA). In the LOS mode of operation, the signal from the Up converter is routed through a filter in the HPA and no amplification is performed. In the Tropo mode the signal is routed through a 5 cavity 1 kW, air cooled amplifier klystron. There the signal is amplified and routed to the diplexer. It operates in the 4.4 to 5.0 GHz band. The klystron and High Voltage Power Supply is not used when operating in the LOS mode. Waveguide Entry Panel- This panel on located on the outside of the shelter. Here we connect the three external wave guides which connect to the antenna. Antenna- The V2 uses two 6 foot parabolic antennas. Signal Flow

V3 Waveguide Entry Panel CECOM LAR Operation Course V3 Waveguide Entry Panel Wave guide Entry Panel #1 (Shown on the left) XMT Is located on the left. This connected the HPA . RCV Is located on the right of Entry Panel #1. This a receive only port and is connected to Down Converter Receiver #1. Waveguide Entry #2(Shown on the right) RCV Located on the right side of Wave guide entry Panel #2. This is a receive only port and is connected to Down Converter Receiver #3. ECCM The top port is not used. It was intended to be used with a ECCM (Electronic Counter-Counter measure up grade. Signal Flow

CECOM LAR Operation Course V3 Block Diagram Receiver Amplifier Converter AM-7026 (Down Converter). The Down Converters contain a LNA and a mixer which converts the 4.4 to 5.0 GHz to a 70 MHz IF. Two Down Converters are used for space diversity reception. IF Test Panel 7A5. The IF Test Panel contains a loop back circuit and an antenna alinement circuit. The loop back circuit provides a calibrated means of applying the Tropo Modem modulator IF output to any one or any combination of Tropo Modem demodulator inputs. The two 70 MHz IF signals are split and routed to the 4 inputs in the TM. Tropo Modem-Demodulator 5A6. The demodulator performs the inverse function of the modulator. Specifically, it recovers the Baseband data from the 4 receiver IF inputs. Signal Flow

CECOM LAR Operation Course V3 RF Rack Point out the equipment. Signal Flow

CECOM LAR Operation Course V3 Baseband Rack Point out the equipment. Signal Flow

CECOM LAR Operation Course Summary The most important part to becoming a good Tropo Communicator is understanding the path the signal travels through your equipment. Recap Slide Signal Flow

THIS PAGE LEFT BLANK