Fluoroscopic Image Quality Considerations

Slides:



Advertisements
Similar presentations
Formation Characteristics
Advertisements

Advanced Biomedical Imaging Lecture 4 Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Digital Radiography.
Resident Physics Lectures
RAD 354 Chapt. 28 The Digital Image Spatial resolution Contrast resolution Contrast-detail curve Pt. dose considerations.
Resident Physics Lectures
X-RAYS IN MOTION “Viewing dynamic studies of the human body”
Dr. Mustafa Zuhair Mahmoud Mr.Ali B Alhailiy بسم الله الرحمن الرحيم 1.
Unsharpness Calculations and Resolution By Professor Stelmark.
Fluoroscopy: Viewing Systems
Fluoroscopy Equipment
FLUOROSCOPY.
Seeram Chapter 11: Image Quality
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
Special Imaging Systems
F luoroscopy. 2 Fluoroscopy system 3 Different fluoroscopy systems  Remote control systems Not requiring the presence of medical specialists inside.
Fluoroscopy Intro to EQUIPMENT
Quality Control.
Image Quality Radiographic Resolution.
Fluoroscopy Equipment. Introduction Fluoro: is dynamic radiographic examination Fluoroscopy is primarily domain of the radiologist The role of radiographer.
Geometric Factors Focal Spot Object Film Object b a h c Film B A H C
Rad Tech 265 More Digital Imaging. Digital Fluoroscopy Radiation dose –Patient dose for DF is significantly less than conventional fluoro At 7.5 pulses/second.
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Exposure Factors or Prime Factors
Appendix H: Chapter 40: Fluoroscopy
What is being tested? (kVp, mA, mAs, mR?) What is the purpose of the HVL test? If an x-ray tube does not pass the HVL test what is done to correct the.
Radiographic Quality Visibility and Sharpness
Image Quality Q&A. RAPHEX Diagnostic Question 2001 D9: The imaging system which is best for visualizing small high contrast objects is: A. Computed tomography.
RAD 150 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic (motion)
RAD 354 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Fluroscopy and II’s. Fluroscopy Taking real time x-ray images Requires very sensitive detector to limit the radiation needed Image Intensifier (II) is.
Sergeo Guilbaud School of Radiologic Sciences
FLUOROSCOPY & IMAGE INTENSIFICATION Sergeo Guilbaud, RT School of Radiologic Sciences.
RADIOGRAPHIC QUALITY S. Guilbaud, Education Director School of Radiologic Sciences.
Exposure Factors or Prime Factors
IMAGE QUALITY. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Chapters 21 & 22.
Resident Physics Lectures
Introduction to and History of Fluoroscopy Radiation Protection
Image quality and Performance Characteristics
Radiographic Contrast
Imaging System Components
Quality Control Testing of Screen Speed
Fluoroscopic Unit Thomas Edison 1896.
כיצד נרכשת התמונה בסרט הרנטגני?
Fluoroscopy: Dynamic Imaging Systems
Resident Physics Lectures
Resident Physics Lectures
Fluoroscopy Dynamic Image Recording Systems
Fluoroscopic Brightness Control Systems
Fluoroscopic Image Intensifier Image production
Mobile Fluoroscopy Based on:
Mobile Fluoroscopy Based on:
Fluoroscopy Dynamic Image Recording Systems
Fluoroscopy: Viewing Systems
Introduction to and History of Fluoroscopy Radiation Protection
Fluoroscopy Static Image Recording Systems
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy – Viewing Systems Optical Mirrors TV Camera & TV Camera Tubes Charge Coupled Devices (CCD) Based on: Principles of Radiographic Imaging, 3rd.
Fluoroscopy – Viewing Systems TV Monitors
Fluoroscopy Static Image Recording Systems
Digital Fluoroscopy PPT created by: Jed Miles, BSRS, RT(R), CRT-CA
Fluoroscopic Image Intensifier Image Production
Fluoroscopy: Static Image Recording Systems
Mobile Fluoroscopy.
Fluoroscopic Image Quality Considerations
Brightness Control Systems
Presentation transcript:

Fluoroscopic Image Quality Considerations

Factors to be considered are: (Quantum Noise or Scintillation) Image Quality Because the “imaging chain” of a fluoroscopic system is a complex system, there are more factors that affect image quality as compared to static radiography Factors to be considered are: Contrast Resolution Distortion Quantum Mottle (Quantum Noise or Scintillation)

(This affects overall image contrast exactly as in static imaging) Image intensified fluoroscopic contrast is affected by: Scattered ionizing radiation (same as static radiography) Penumbral light scatter from input and output screens Light scatter within the image intensification tube Transmitted incident primary beam striking the output phosphor Image contrast can be increased and/or controlled by electronically increasing the amplitude of the video signal Background Fog All of these phenomena contribute to produce a background ‘fog’ that raises the base density of the virtual image (This affects overall image contrast exactly as in static imaging)

Contrast An inherent decrease in image contrast near outer (or peripheral) edges of fluoroscopic image Increasing lowest density value decreases total visible contrast Lowest Density Value Total Visible Contrast Due to imperfect intensifier tube and electron beam geometry Overall effect is of reduced image contrast

Image Quality – Resolution Resolution is the ability of the imaging system to differentiate small objects as separate structures when they are positioned closer together Measured in line pairs per millimeter (lp/mm) Object size Spatial frequency Inverse Relationship As object size becomes smaller, the spatial frequency becomes higher Overall resolution of an imaging system is expressed in terms of its “modulation transfer frequency” (MTF) as a function of spatial frequency

Resolution Modular Transfer Function (MTF) “A” is a set of patterns of dark and light bars. There are 4 sets of bars at increasingly smaller spacing. “B” is an “image” of what those bars might look like when imaged by a lens. The edges of the dark and light regions will be blurred. The closer the spacing, the more blurred they become.

Resolution Ability to resolve recorded detail will vary depending on geometrical factors: (same as static radiography) Input and output screen diameter Minification Gain Electrostatic Focal Point Viewing System Resolution (monitor resolution) Phosphor crystal size and thickness OID Geometrical factors are of a different nature than in static radiography

Resolution Capabilities Zinc-cadmium input phosphor intensifier tubes 1-2 lp/mm Cesium iodide (CsI) input phosphor image intensifiers 4 lp/mm Optical mirror systems that permit “indirect” viewing of the fluoro output screen 3 lp/mm Magnification or multi-field image intensifiers 6 lp/mm (in mag mode)

Size Distortion Size distortion is caused by the same factors that affect static radiography magnification: OID Multifield image intensifiers that produce magnification by changing the electrostatic focal point do not significantly affect actual size distortion Some size distortion is always present in the minified image Size distortion becomes more visible in a magnified image

Is significant when distorting 8-10% of the image area Shape Distortion Is significant when distorting 8-10% of the image area Shape distortion (pincushion) is primarily caused by shape of image intensification tube Inherent edge distortion at output screen even with concave input screen Electron stream focusing not uniform across entire field of image intensifier Electrons at outer edges of image flare outward as they are electrostatically focused Due to repulsion of like charges Partially due to divergence of primary x-ray beam

Vignetting Center of output screen brighter than periphery due to unequal magnification of the electron stream causing unequal illumination at output phosphor In center of image: Resolution is better Distortion is minimized Contrast is improved periphery center

Veiling Glare Veiling glare is mainly the consequence of light scatter in the output window of the image intensifier Scattered light (like scattered radiation) adds to the background signal Thus, the contrast of the image is reduced Measuring the contrast ratio of an image intensifier is a good method to quantify the magnitude of this problem

Quantum Mottle, Quantum Noise, Scintillation Blotchy or grainy appearance caused by insufficient radiation to create a uniform image Static radiography: mA and time as mAs controls quantity of photons creating density on image receptor Fluoroscopy: factor of time limited by length of time human eye can accumulate or integrate enough visible light photons from the fluoro imaging chain to be perceived This time period is 0.2 seconds Fluoro mA must be high enough to avoid excessive mottle as perceived by the observer

Quantum Mottle, Quantum Noise, Scintillation Creates a special problem as fluoro units are operated with the minimum mA (dose) possible to activate the fluoro screen Quantum Mottle, Quantum Noise, Scintillation Inherently present in any electronic video system as ‘video noise’ or ‘electronic noise’ Creates a special problem as fluoro units are operated with the minimum mA (dose) possible to activate the fluoro screen A low SNR would produce an image where the "signal" and noise are more comparable and thus harder to discern from one another mA too low causes “excessive” quantum mottle / scintillation The image above has a sufficiently high SNR to clearly separate the image information from background noise mA increased enough to permit image signal to be visualized

Quantum Mottle, Quantum Noise, Scintillation Factors affecting quantum mottle include: Solutions Increasing efficiency of any of these will reduce quantum mottle Viewing system (direct, monitor, film, etc.) Initial Radiation Output Efficiency Quantum Mottle Conversion efficiency of input screen Total Brightness Gain Common solution is to increase fluoro tube mA Distance of observer from viewing sytem (inverse square law of light) Beam attenuation by subject matter (Results in an increased patient dose rate)

Quantum Mottle Another factor affecting quantum mottle is: Time How long the x-ray tube is energized by the fluoroscopist The fluoro “mA” must be high enough to avoid excessive mottle as perceived by the observer This is because the human eye needs 0.2 seconds to accumulate or integrate enough visible light photons from the fluoro imaging chain for an image to be percieved The minimum amount of time needed for a “look” is 0.2 seconds

Please close this PowerPoint presentation, and continue the lesson. What’s Next? Please close this PowerPoint presentation, and continue the lesson. Presented by Based on: Principles of Radiographic Imaging, 4th Ed. By: R. Carlton & A. Adler Radiologic Science for Technologists, 8th Ed. By: S. Bushong Syllabus on Fluoroscopy Radiation Protection, 6th Rev. By: Radiologic Health Branch – Certification Unit