ECE 576 Power System Dynamics and Stability

Slides:



Advertisements
Similar presentations
EE 369 POWER SYSTEM ANALYSIS
Advertisements

ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
TCIPG Reading Group Today’s Plan: Discuss Read and Work Ahead
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
Power Flow Problem Formulation
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems Prof. Hao Zhu Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
EE 369 POWER SYSTEM ANALYSIS
ECE 333 Renewable Energy Systems Lecture 14: Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
ECE 333 Renewable Energy Systems Lecture 13: Per Unit, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Per Unit Representation Load Flow Analysis Power System Stability Power Factor Improvement Ashfaq Hussain.
05 August 2015 Delft University of Technology Electrical Power System Essentials ET2105 Electrical Power System Essentials Prof. Lou van der Sluis Energy.
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
Load Flow Study using Tellegen’s Theorem. Load Flow – The load-flow study is an important tool involving numerical analysis applied to a power system.
Announcements Homework #4 is due now Homework 5 is due on Oct 4
ECE 476 Power System Analysis Lecture 11: Ybus, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
ECE 476 Power System Analysis Review 1 Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign
Lecture 13 Newton-Raphson Power Flow Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
The Power Flow Problem Scott Norr For EE 4501 April, 2015.
Lecture 11 Power Flow Professor Tom Overbye Special Guest Appearance by Professor Sauer! Department of Electrical and Computer Engineering ECE 476 POWER.
ECE 476 Power System Analysis Lecture 12: Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems Prof. Hao Zhu Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Optimal Power Flow- Basic Requirements For Real Life Their Problems And Solutions.
ECE 476 Power System Analysis Lecture 13: Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
ELEN 3441 Fundamentals of Power Engineering Spring Lecture 10: Power-Flow studies Instructor: Dr. Gleb V. Tcheslavski Contact:
Lecture 10 Transformers, Load & Generator Models, YBus Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Power in AC Circuits Introduction Power in Resistive Components
Announcements Please read Chapter 6
Announcements Please read Chapter 2.4, Chapter 6 up to 6.6
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECEN 460 Power System Operation and Control
ECE 476 Power System Analysis
Sinusoidal Excitation of Circuits
ECEN 460 Power System Operation and Control
ECE 476 Power System Analysis
ECE 476 Power System Analysis
ECEN 460 Power System Operation and Control
CHAPTER 2: DC Circuit Analysis and AC Circuit Analysis
Islamic University of Gaza
ECE 476 POWER SYSTEM ANALYSIS
Load flow solutions Chapter (3).
SWAMI VIVEKANAND COLLEGE OF ENGINEERING,INDORE(M.P)
ECEN 460 Power System Operation and Control
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECEN 460 Power System Operation and Control
UNIT-II POWER FLOW ANALYSIS
ECE 333 Green Electric Energy
Power in AC Circuits Introduction Power in Resistive Components
OUTAGE MODELING: PQ BUS NUMERICAL ANALYSIS & RESULTS
Load Flow Studies Eng. Edvan Moyo BEng, MEng, MBA
Submodular Optimization for Voltage Control in Power Systems
The Power Flow Problem Scott Norr For EE 4501 April, 2017.
ECE 333 Green Electric Energy
ECEN 460 Power System Operation and Control
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
ECEN 460 Power System Operation and Control
ECEN 460 Power System Operation and Control
ECE 576 POWER SYSTEM DYNAMICS AND STABILITY
ECE 333 Green Energy Systems
ECE 576 POWER SYSTEM DYNAMICS AND STABILITY
ECE 576 POWER SYSTEM DYNAMICS AND STABILITY
ECE 576 POWER SYSTEM DYNAMICS AND STABILITY
ECEN 615 Methods of Electric Power Systems Analysis
ECEN 615 Methods of Electric Power Systems Analysis
ECEN 460 Power System Operation and Control
Module T7 Power Flow Read Module T7.
Prepared by: Ismael K. Saeed
ECE 2202 Circuit Analysis II
ECEN 615 Methods of Electric Power Systems Analysis
Presentation transcript:

ECE 576 Power System Dynamics and Stability Introduction to Power Flow Analysis Dr. Karl Reinhard Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign reinhrd2@illinois.edu

Introduction We seek to analyze the power system performance under steady state conditions. The analysis in normal steady-state operation is called a power-flow study (load-flow study) and it targets on determining the Voltages, Currents, and Real and Reactive Power Flows in a system under specified generation and load conditions. At each bus, We make an assumption about either a Voltage at a bus or the Power being supplied to the bus Then determine Bus voltage magnitude and phase angles Line currents, etc. that would result

Basics for Power-flow Studies. The way ahead…. to find the power-flow solution via iteration: Create a bus admittance matrix Ybus for the power system; Make an initial estimate for the voltages at each bus in the system; Iterate to find conditions that satisfy the system’s load flow equations. Update the voltage estimate for each bus (one at a time), based on the estimates for the voltages and power flows at every other bus and the values of the bus admittance matrix. Since the voltage at a given bus depends on the voltages at all of the other busses in the system (which are just estimates), the updated voltage will not be correct. However, it will usually be closer to the answer than the original guess. Repeat this process to make the voltages at each bus approaching the correct answers to within a set tolerance level…

Basics for power-flow studies The equations used to update the estimates differ for each of 3 bus types. Load bus (PQ bus) – All buses not having a generator Real and reactive power (P and Q)are specified Bus voltage magnitude and phase angle (V and q) will be calculated Real and reactive powers supplied to a power system are defined to be positive Powers consumed from the system are defined to be negative. 2. Generator bus (PV bus) – Voltage and real power supplied are specified Bus phase angle (q) will be calculated during iteration Reactive power will be calculated after the case’s solution is found

Basics for Power-flow Studies. 3. Slack bus (swing bus) – Special generator bus serving as the reference bus for the power system. Voltage is fixed – both magnitude and phase (for instance, 10˚ pu). Real and reactive powers are uncontrolled – supplies whatever real or reactive power is necessary to make the power flows in the system balance. Key Points: Voltage on a load bus (P-Q bus) changes as the load varies – P and Q are fixed, while V (magnitude and angle) vary with load conditions. Generators (@ P-V buses) work most efficiently when running at full load – P and V are fixed Slack bus generator varies P and Q that it supplies to balance Complex power – V and Angle reference are fixed.

Ybus for Power-flow Analysis The basic equation for power-flow analysis is derived from the nodal analysis equations for the power system: I12 I32 I42 I2

Power-flow Analysis Equations The basic equation for power-flow analysis is derived from the nodal analysis equations for the power system: (1) For the four-bus power system shown above, (1) becomes (2) where Yij are the elements of the bus admittance matrix, Vi are the bus voltages, and Ii are the currents injected at each node. For bus 2 in this system, this equation reduces to (3)

Ybus for Power-flow Analysis Example: a simple power system has 4 buses, 5 transmission lines, 1 generator, and 3 loads. Series per-unit impedances are: Note: Ybus symmetric construction – Off diagonal elements are -Yij = -Yji line # Bus to bus Series Z (pu) Series Y (pu) 1 1-2 0.1+j0.4 0.5882-j2.3529 2 2-3 0.1+j0.5 0.3846-j1.9231 3 2-4 4 3-4 0.5+j0.2 1.1765-j4.7059 5 4-1

Ybus For Power-flow Analysis Example: a simple power system has 4 buses, 5 transmission lines, 1 generator, and 3 loads. Series per-unit impedances are: Note: Ybus symmetric construction – On diagonal elements: line # Bus to bus Series Z (pu) Series Y (pu) 1 1-2 0.1+j0.4 0.5882-j2.3529 2 2-3 0.1+j0.5 0.3846-j1.9231 3 2-4 4 3-4 0.5+j0.2 1.1765-j4.7059 5 4-1

Power-flow Analysis Equations However, real loads are specified in terms of real and reactive powers, not as currents. The relationship between per-unit real and reactive power supplied to the system at a bus and the per-unit current injected into the system at that bus is: (4) where V is the per-unit voltage at the bus; I* - complex conjugate of the per-unit current injected at the bus; P and Q are per-unit real and reactive powers. Therefore, for instance, the current injected at bus 2 can be found as (5) Substituting (5) into (3), we obtain (6)

Power-flow Analysis Equations (6)

Power-flow Analysis Equations B G (6)

Non-Linear – Newton Raphson Solution

Information from power-flow studies The basic information contained in the load-flow output is: All bus voltage magnitudes and phase angles w.r.t the slack bus. All bus active and reactive power injections. All line sending- and receiving-end complex power flows. Individual line losses can be deduced by subtracting receiving-end complex Power from sending-end complex power. Total system losses – deduced by summing complex power at all loads and generators and subtracting the totals.

Information From Power-flow Studies The most important information obtained from the load-flow is the system voltage profile. A power-flow program can be set up to provide alerts if the voltage at any given bus exceeds, for instance, 5% of the nominal value  such voltage variations may indicate problems… If │V│ varies greatly over the system, large reactive flows will result; this, in turn, will lead to increased real power losses and, in extreme cases, an increased likelihood of voltage collapse. When a particular bus has an unacceptably low voltage, the usual practice is to install capacitor banks in order to provide reactive compensation to the load.