CECOM LAR Tropo Operation Course

Slides:



Advertisements
Similar presentations
AU-200 Digital Audio Workstations Mbox 2 overview.
Advertisements

Isolation Verification Control Mining - Marine - Transit – Solutions LIVE Distributed By Locksafe Industrial Safety Equipment.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Orion Telecom Networks Inc Slide 1 E2, 2Mbps x 4 Opti Multiplexer Integrated E2, OLTE and Multiplexer Updated : January, , Avenue of Fountains,
GS3055-I GSM Universal Wireless Alarm Communicator
Trouble - Shooting ELR - Electric Latch Retraction.
Engineer Training Control Unit TJ8300 / TJ8500 Control Unit.
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
SGI Confidential Copan 400 Installation. SGI Confidential Installation Overview The approximate minimum time to complete this procedure is.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
PLC Fundamentals Module 2: Hardware and Terminology.
Using Your Arduino, Breadboard and Multimeter Work in teams of two! living with the lab 1 © 2012 David Hall.
Embedded Programming and Robotics
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
The physical network Unit objective: Identify network cables and connectors, and use networking tools.
June 2008 R&D Center / BCS HW Team Introduction to iPECS P5 Hardware.
RM2F Input / Output (I/O) Pin grouping code!. I/O Pin Group Operations: The Spin language has provisions for assigning values to groups of bits in the.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
Basic Stamp Free Pins These pins can be used by the operator for digital Inputs and Outputs Used Pins 0.
Datron World Communications Inc. RT7000 HF TRANSCEIVER FIELD MAINTENANCE PROCEDURES.
User’s Manual INSTALLATION / OPERATION 1/3 4ch or 8ch UTP Receiver (1U Rack Type) ONU - R4000 ONU - R8000.
GS3055-I GSM Universal Wireless Alarm Communicator
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
Codan 5700 Series C-Band Transceiver Technical Overview.
Page 1 LXMG , LXMG LXMG , LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Modules Training.
Acquisition Crate Design BI Technical Board 26 August 2011 Beam Loss Monitoring Section William Vigano’ 26 August
Ethernet I/O Set-Up This presentation will step through a typical configuration of the DVT CON-IOE. Intellect 1.0 is used for the software portion.
FEB Slide 1 Task No.:Point(s):1Only one answer is correct.Cat. No. To measure electrical … A current, the ammeter must be in line with the current.
Page 1 LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Module Training Kit Rev 1.1 November 2006
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Introduction to IP Cameras Over Coax. Replacing Analog Cameras With IP Cameras Over Coax Analog Camera RG59U Coaxial Cable 18/2 Power Cable Low Voltage.
Power Supply. 2 Power Supply w/Line Conditioner The power supply is the heart of the Millenium System. It can support between 15 DCD boards (power for.
Brooks Expert Support Tool (BEST) Software
Technical Specification
Site Controller Unit and Trunk Interface Unit
음향 시스템 사양서 POWER SUPLY WITH 3.5 PHOENIX CONNECTOR AMX: PSN6.5
AUTOMATIC STREET LIGHT CONTROL USING LDR
Redundancy Switching Components
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
HVI HIPOT TEST SET Pft sERIES.
ARDUINO     What is an Arduino? Features 14 Digital I/O pins 6 Analogue inputs 6 PWM pins USB serial 16MHz Clock speed 32KB Flash memory 2KB SRAM.
PLC Hardware Components.
Chapter 2 Push button and Potentiometer
ET 438B Sequential Control and Data Acquisition
NI Data Acquisition (DAQ) Wiring and Connections
Wiring the Light and Relay
Module 1 – Power Supply AMC APS-PBC-60
Unit 2 Introduction to the AN/TRC-170
CECOM LAR Tropo Operation Course
CECOM LAR Tropo Operation Course
CECOM LAR Operation Course
AM-7027 Up Converter-Amplifier
AM-7026 Down Converter-Receiver
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
AC POWER REQUIREMENTS & AC TO AC CONVERTER
SN-553 Frequency Synthesizer
CECOM LAR Operation Course
ACOE347 – Data Acquisition and Automation Systems
CECOM LAR Operation Course
CECOM LAR Tropo Operation Course
TD-1236 Trunk Group Multiplexer
ORDERWIRES CECOM LAR Course CONUS Branch FT McPherson, GA.
Let’s use a PUSH-Button!
TD-1235 Loop Group Multiplexer
AN/TRC-170 COMSEC Devices
CECOM LAR Operation Course
Student Studyguide Unit 3 Major Systems and Functions
Presentation transcript:

CECOM LAR Tropo Operation Course MD-1026 (GM) CECOM LAR Course CONUS Branch FT McPherson, GA TITLE PAGE MD-1026 GM

CECOM LAR Tropo Operation Course Purpose Converts CDI to NRZ Routes cable DVOW to/from OCU Routes cable AVOW to/from AVOW unit RECAP SLIDE MD-1026 GM

CECOM LAR Tropo Operation Course Specifications Dimensions 19” X 8.5” X 12” deep Weight 35 lb. Input Power 115 VAC  10%, 47 to 420 Hz Data Rates- 72 KB/s to 4608 KB/s RECAP SLIDE MD-1026 GM

CECOM LAR Tropo Operation Course Block Diagram 1. Show NRZ and CDI sides of equipment. 2. Show where DVOW is extracted. MD-1026 GM

CECOM LAR Tropo Operation Course C&I A- TEST- This push-button switch energizes the BITE circuit in a test mode to light all fault lamps on the GM or fault LED on A4 - A16. B- LOSS OF INPUT- This lamp lights if the GM loses an external input. The associated CCA fault lamps also lights. Operator should check the LS (Line Side) light on the Alarm Monitor. If On, the LOI is from the Cable Side C- PWR SUPPLY- A lamp, which lights if one or more power supply voltages is out of tolerance. Operator should open cover of Power Supply to see which CCA Fault Lamp is lit. D- SUMMARY- Illuminates when the GM detects a fault. E- Label- A label on the front panel which indicates internal controls and indicators. F- Power ON/OFF- Switches 115 V AC on/off G- POWER- A lamp indicates 115 V AC has been applied. H- MAIN POWER- A front panel Circuit Breaker that provides over current protection MD-1026 GM

CECOM LAR Tropo Operation Course C&I A- FAULT-This red LED indicates a fault has been detected on the AC input CCA. B- FAULT- The red LED indicates a fault has been detected on the multi VDC CCA. C- FAULT- A red LED indicating a fault has been detected on the 5 VDC CCA. D- FAULT- A red LED lights if DPHS A CCA malfunctions or lacks proper input. E- FAULT- A red LED lights if DPHS B CCA malfunctions or lacks proper input. This usually means that there is no Orderwire, and Switch G is set to SYS. Try setting Switch G to MAINT F- FAULT- A red LED lights if BITE 1 CCA malfunctions. G- OW SYST/ MAINT- Toggle switch selects either System Orderwire or MAINT analog voice orderwire function. This will normally be in the SYS position as Orderwire is being extracted from the Data Stream. H- RATE Thumbwheel selects the group data rate. MD-1026 GM

CECOM LAR Tropo Operation Course Group Rate Settings 0 OFF 1 72 2 128 3 144 4 256 5 288 6 512 7 576 8 1024 9 1152 10 1536 11 2048 12 2304 13 4096 14 4608 This Setting is found on each DPHS A CCA. Setting will be set to input Data Rate. All unused MODEMS will be set to 0 (Zero) MD-1026 GM

CECOM LAR Tropo Operation Course C&I   A- Group 1-4- Multi-pin connectors, these are the NRZ BAL input/output going to the BBPP. B- LINE SIGNAL- BNC Connectors, these are the 4 group outputs OUT 1-4 (CDI) to the Roadside Entry Panels. C- LINE SIGNAL- BNC Connectors, these are the 4 group inputs IN 1-4 (CDI) from the Roadside Entry Panels. D- TO ROA- These multi-pin connectors are not used. They GROUP 1-4 are for a Fiber Optic Upgrade, which was planned, but since has been dropped. E- POWER- 115 V AC input power. F- GND- External Ground connector G- ORDERWIRE- These connectors route the Orderwire as described in the Transmit section. H- STATION CLK AND ALARM- Provides Station Clock derived from CDI input. MD-1026 GM

CECOM LAR Tropo Operation Course Summary- MD-1026 Contains 4 Group Modems Converts CDI to NRZ and vice versa Processes and Routes Orderwire Signals show I/O Summarize MD-1026 MD-1026 GM