Motor Data 890 RPM vertical motor Stator slots = 84, Rotor Bars = 68 Bearings / Fault Frequencies
Velocity Overall History. No changes thru 12/21/12
Spike Energy Trend. No change 12/31/12 12/31/12
Acceleration Trend. Slight increase on 12/31/12? 12/31/12
1A waterfall
1H1 waterfall
1H2 waterfall
2A waterfall
2H1 waterfall
2H2 waterfall
3H1 waterfall
3H2 waterfall
1A compare (log scale). RPM=890.8, 890.4. <=2*LF SSPF <=6*LF 2*lf SB <=7x <=3.17 = bpor <=1x <=4.00 2*lf SB 2*lf SB 2*lf SB <=4*LF 2*lf SB 2*lf SB RBPF <=2*bpfi+1 <=3*bpfi-1 RPM=890.4 <=bpfi-1V <=bpfi <=3*bpfi <=bpfi+1 <=2*bpfi-1 <=3*bpfi+1 <=5*bpfi-1 <=5*bpfi/6LF <=6*bpfi+1 <=2*bpfi <=4*bpfi <=4*bpfi+1 <=6*bpfi <=7*bpfi+1 <=2*LF <=7*bpfi <=9*bpfic SSPF <=9*bpfi+1x <=8*bpfi-1x <=11*bpfi+1 <=8*bpfi <=12*bpfi-1 <=12*bpfi <=12*bpfi+1 <=11*bpfi <=13*bpfi+1 2*lf SB <=9*bpfi-1x <=11*bpfi-1 <=13*bpfi-1 <=13*bpfi <=14*bpfi <=10*bpfi-1 <=10*bpfi <=18*bpfi <=18*bpfi+1 <=3.17 = bpor <=15*bpfi-1 <=14*bpfi-1 <=15*bpfi <=15*bpfi+1 <=16*bpfi+1 2*lf SB <=17*bpfi <=16*bpfi <=17*bpfi-1 <=19*bpfi
1H1 compare (log scale)
1H2 compare (log scale)
2A compare (log scale)
2H1 compare (log scale). Non-sync ~ 1.5 on
2H2 compare (log scale)
3H1 compare (log scale)
3H2 compare (log scale)
Look closely for BPIR 12/13/12…No BPIR series in sight Look closely for BPIR 12/13/12…No BPIR series in sight. However tiny BPOR has been present/growing slightly since installation
Waterfall with frequency trend of [minor] BPOR evolution
BPOR evolution 2/28/11
BPOR evolution 5/23/11
BPOR evolution 8/16/11
BPOR evolution 11/7/11
BPOR evolution 12/14/2011
BPOR evolution 1/30/12
BPOR evolution 4/24/12
BPOR evolution 10/9/12
BPOR evolution 12/31/12