MODELING DG IN BASE CASES

Slides:



Advertisements
Similar presentations
Summary of Second Draft of the NERC Standard PRC Disturbance Monitoring and Reporting JSIS Meeting August 10, 2010 Salt Lake City, UT.
Advertisements

Questions about AVR & PSS
Model Specification Requirements MSRATF Meeting – Mar 11, 2013 Stephanie Lu, MVWG Chair Seattle City Light.
Distributed Generation (DG)
Connection of Wind Farms to Weak AC networks – ERCOT Experience and Challenges Shun-Hsien (Fred) Huang ERCOT System Planning CIGRE WG B4.62 Meeting June.
Energy Storage Systems Prof. G. Bothun Dept. of Physics University of Oregon.
1 Smart Distribution Systems: Sustainability Issues S. S. (Mani) Venkata Alstom Grid and University of Washington (UW)
1 FRCC Compliance Organization and Entity Registration 2008 FRCC Compliance Workshop.
Novel Strategies to Reduce Variation of Wind and Solar Generation at its Source Stephen Rose Eric Hittinger.
Net Metering and Embedded Generation NB Climate Action Change Hub Advisory Committee Meeting – October 1, 2008 Saint John, NB Linda Berthelot.
Distributed Generation Registration June 30, 2008.
RiversidePublicUtilities.com Arts & Innovation RiversidePublicUtilities.com MOD GENERATOR TESTING REQUIREMENTS RESOURCE PLANNERS LeeAnne Uhler, Regulatory.
SERC Reliability Corporation 1 SERC RELIABILITY CORPORATION MID-AMERICA RELIABILITY CONFERENCE June 21, 2006 COLUMBUS, OHIO.
ERRA 4th Annual Conference May 19, Budapest, Hungary. Latvia Country Update UPDATE ON REGULATION Ainars Čunčulis Head of Energy Department Public.
Renewable & Alternative Power Implementation of the California Renewables Portfolio Standard February 6, 2007 Senate Energy, Utilities, and Communications.
Jagan Mandavilli Senior Reliability Engineer Texas RE NERC DERTF Update ERERERCOT WMS June 3, 2015.
Energy: Challenges with Becoming More Sustainable © 2011San Diego Gas & Electric Company. All copyright and trademark rights reserved. Robb Anderson Director.
WECC REMTF Workshop Spencer Tacke WECC Renewable Energy System Models Workshop March 9, 2016.
Interpreting HB 3693 Interstate Renewable Energy Council
Interconnecting Wind & Solar Energy in Texas
Modeling DER in Transmission Planning CAISO Experience
SCE Energy Storage Perspective
Energía eólica // Wind energy
Western Electricity Coordinating Council
Transmission Planning Base Case Loads & Transmission System Model
DWG Meeting March 7, 2017 (Update to a Meeting held July 26, 2016)
GSR022: Review of Security and Economy Required Transfer Conditions
Operationalizing One Nation One Grid
WECC Load Modeling and Validation Group Meeting
Use other resources to generate electricity
Grid Integration of Intermittent Resources
East Bay Community Energy Local Development Business Plan
EE5900: Cyber-Physical Systems
Current as of 12/12/2017 RES-BCT.
DISTRIBUTED GENERATION (DG) MODELING CRITERIA SWEDE 2016
Design of Electric Power Systems and Utilities
EU-IPA12/CS02 Development of the Renewable Energy Sector
DEC System Voltage Planning - June 2018
Distributed Generation (DG) Modeling Criteria
WECC REMTF Workshop Spencer Tacke
Presenter: Peter Heidrich, FRCC – BES Drafting Team Chair
Renewable Energy. Sustainable Future.™
CMPLDWG Composite Model with Distributed Generation Approval
Holy Cross Energy CREA Energy Innovations Summit 2016
NERC-WECC Coordination
Jonathan young ColumbiaGrid
2500 R Midtown Sacramento Municipal Utility District
Min/Max Load field Addition
ADS and WPR Seed Case Background
NERC-WECC Coordination
Byron Woertz, Manager—System Adequacy Planning
Composite Load Model with Distributed Generation (CMPLDWG)
MODELING DG IN BASE CASES
Study Results PC8-PC16 System Stress Tests
CMPLDWG Composite Model with Distributed Generation Approval
Byron Woertz, Manager—System Adequacy Planning
WECC Load Modeling and Validation Group Meeting
Donald Davies Chief Senior Engineer
TONBRIDGE POWER GREEN LINE
ADS and WPR Seed Case Background
Min/Max Load field Addition
User Experience with New Solar PV Models California ISO
WECC REMTF Workshop Spencer Tacke
—Two power conditioning units (PCU)’s needed only if batteries are added for grid failure —AC output is consistent with the requirements of most loads.
System Review Work Group Update to TSS
WECC REMTF Workshop Spencer Tacke
Solar Energy Commercialization Utility Scale Business:
National Institute of Wind Energy(NIWE)
PA Supplier Workshop Net Metering September 10, 2019.
UM 1856 PGE’s Energy Storage Proposal – Commission Workshop #1
Presentation transcript:

MODELING DG IN BASE CASES 1/24/2018

DPM Generator Modeling Guidelines Page 10 – 2018 DPM…… Modeling of generators shall comply with the following: If the individual-generator-unit capacity is 10 MVA or larger and the generator is connected to the WECC transmission system at 60 kV or higher, then submit steady-state data and dynamics data for each generator. If the aggregated-generator-unit capacity is 20 MVA or larger, the generators are connected to the WECC transmission system at 60 kV or higher, and it is not a collector-based generation facility− then submit steady-state data and dynamics data for each generator. (Wind and solar farms are examples of collector-based generation facilities.) If the aggregated-generation capacity is 20 MVA or larger, the generators are connected to the WECC transmission system at 60 kV or higher, and it is a collector-based generation facility− then submit steady-state data and dynamics data for the aggregated generation capacity as a single-unit generator model. All other generating facilities shall be netted with bus load in steady-state data and have their Non-Conforming Load Flag set appropriately. Steady-state and dynamic generator data shall be consistent.

Distributed Generation DG expected to be significant in future years (some states have RPS requirements for DG) DG can be any resource connected on the distribution grid – hydro, solar, energy storage etc Two types of DG - Utility scale (community solar etc). Historical output and location should be known - Commercial and residential. Historical output data may not be available Dynamic Model – CMPLDWG not approved for base case implementation by MVWG Implement Power flow model for now

DG Criteria Any member already modeling DG ? Criteria Used ? Power flow Model – Change existing Criteria? New Criteria? 1. Model DG if > a percentage of load Plot on next slide 2. Model DG > a set MW ? Different criteria for Utility scale and Residential/Commercial?

2018HS4.sav – Load Analysis X-axis: Load from 0 to 10MW Y-axis: count of loads above a MW value by area