-Bypass/Isolation Switches-

Slides:



Advertisements
Similar presentations
All Russelectric 4 pole Open Transition ATS’s have a fully rated -break before make- switched neutral, identical in every way to the main power poles and.
Advertisements

Closed Transition ATS’s
Automatic Transfer Switch (ATS)
Variable Frequency Drives Bypass Options
B757 Review Questions.
Introduction to Switchgear
ETC is your One-Stop-Shop for control upgrades on all types of Automatic Transfer Schemes: Emergency Transfer Controls Automatic Transfer Switches (ATS.
VL Connector To introduce the VL wire-to-board and wire-to-wire, crimp style connector series.
Thermostats, Pressure Switches, and Other Electric Control Devices
HYDRAULICS & PNEUMATICS
Automatic Transfer Switch using microcontroller
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
De-energization and Lockout
KLINGE’S NMR 262 Two Independent Systems Integrated into one Unit This Requires Special Features:  Total Redundancy of Refrigeration Components  Total.
ATS Popular Features and Accessories John J. Stark Marketing Services Coordinator, Russelectric Inc.
Transferring Inductive Type Loads John J. Stark Marketing Services Coordinator, Russelectric Inc. (Refer to Russelectric Technical Brief: “Eliminating.
The Vanjen Group • Manufacture's Representative – Power Generation/Oil & Gas • Covering TX, OK, LA, AK, in some cases NM and MS • Extensive.
Manufacture's Representative – Power Generation/Oil & Gas Covering TX, OK, LA, AK, in some cases NM and MS Extensive Power Gen Experience Extensive Docking.
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
Chapter 7 SYSTEM PROTECTION
ABS(Antilock braking system)

SISTEMA Example One. Schneider Electric – Sistema Example 1 – June Example 1: Start/Stop Facility with Emergency Stop Device Circuit Diagram.
Mehran University Of Engineering & Technology, SZAB Khairpur Mirs Campus ENGR. AHSANULLAH MEMON LECTURER DEPARTMENT OF ELECTRICAL ENGINEERING MUCET KHAIRPUR.
Electro-Pneumatics Module 1
THE ELECTRIC SUB STATION
Uninterruptible Power Systems
Net Optics Confidential and Proprietary 1 Bypass Switches Intelligent Access and Monitoring Architecture Solutions.
Introduction to switchgears
SERVICE ENTRANCE EQUIPMENT
Main contacts closed – RED Colour with ON
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Basic study of a switch Unit 3.Lesson 3. A switch Purpose A switch is a mechanical device used to connect and disconnect a circuit at will Parts seen.
Teknologi Pusat Data 12 Data Center Site Infrastructure Tier Standard: Topology Ida Nurhaida, ST., MT. FASILKOM Teknik Informatika.
Series and Parallel Circuits. Series Circuits ► Are the simplest type of circuits. ► Series circuits – all the components (lamps, cells, switches, etc.)
A new fail-safe principle for railway signaling
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Auto turn off battery charger Auto turn off battery charger.
MCB Connor, Sunny, Kia. What does it do? A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from.
ELECTRICAL INSTRUMENTS ( service and utilization )
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Equipment 1.Circuit Breaker. 3.Fuses. 4.Protecti- ve relay.2.Bus bar. TYPES OF SWITCH GEAR EQUIPMENT:-
Push Button Station and Relay
Automatic Transfer Switches
Sub Station.
Instrumentation Power Supply - Agenda
SUB-STATIONS.
Circuit Protection Unit 9.
Chapter # 25 Sub-Stations risemark.pbworks.com.
Computer Network Collection of computers and devices connected by communications channels that facilitates communications among users and allows users.
Programmable Logic Control - Agenda
ANTI LOCK BRAKING SYSTEM
DESCRIPTION AND GUIDE TO OPERATIONS
Mersen’s Fused Coordination Panelboard
Technical Guidelines to Turn off Norton 360 Auto Update.
One Line Diagram Example
Circuit Breakers & Reclosers
HVI HIPOT TEST SET Pft sERIES.
What are the Common Symptoms of a Failing Starter Relay.
MAINTENEANCE AND REPAIR OF STARTING SYSTEMS
Chapter 7 © 2010, The McGraw-Hill Companies, Inc..
ELECTRICAL POWER-II Electrical engineering sixth semester
Workbook Section.
Interconnection of AES With The Grid
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
Treatment – Ultraviolet (UV)
PSS0 Design & Concept of Operations
lesson 3.4 DRIVING WITH A MANUAL TRANSMISSION
Presentation transcript:

-Bypass/Isolation Switches- Russelectric Builds Two Types: Failsafe & Maintenance

A Bypass/Isolation switch (switch within a switch)… Benefits and main purpose of a bypass/isolation switch Bypass switching section ATS switching section (mounted in a draw-out assembly) A Bypass/Isolation switch (switch within a switch)… Power can be maintained to load during ATS failure and until the ATS is repaired. Provides a means of bypassing the ATS for maintenance Unit can be operated as a manual transfer switch until the automatic portion is serviced and/or repaired

Bypass/Isolation Functions Variations on the Theme Russelectric offers the most variations, beginning with 2 major considerations: 1. Bypass feature used mainly for maintenance of the automatic transfer switch portion of the unit (Maintenance bypass) 2. Bypass feature used mainly in emergency situations (Failsafe bypass) ATS Portion of unit may be open transition or closed transition, regardless of Maintenance or Failsafe bypass

Maintenance Bypass (All manufacturers offer this type) Advantages: Disadvantages: Can bypass the ATS portion of the unit without disturbing the load Cannot bypass the ATS portion of the unit to the alternate source. RTB(D) - Load Break design (Break-Before- Make Bypass) NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO Design relies on both electrical and mechanical interlocking, arguably reducing reliability. (This interlocking cannot be isolated, so unit must be taken completely off line for servicing.) Routine maintenance on ATS portion of units is possible with by no interruption to the load. X

Maintenance Bypass design Handle LOAD BYPASSED TO NORMAL ATS ATS Contacts are electrically interlocked to prevent bypassing to the alternate source, thus connecting normal and emergency sources together. NORM NORM NORM NORM ISOLATE Load Break Contacts Load Break Contacts Load Break Contacts Load Break Contacts Load Break Contacts Load Contacts Overlap Bypass Handle Bypass Handle AUTO AUTO BPN BPE Load Momentarily Disconnected Load Momentarily Disconnected Load Momentarily Disconnected BPN BPN BPN BPE BPE Bypass Handle Bypass Handle Bypass Handle Bypass Handle Bypass Handle Bypass Handle Bypass Handle Bypass Handle Emergency Power Available LOAD LOAD LOAD LOAD BYPASSED TO NORMAL LOAD BYPASSED TO NORMAL LOAD BYPASSED TO NORMAL Switch Bypassed to Emergency Maintenance Bypass design NORMAL EMERGENCY EMERGENCY EMERGENCY

X Bypass Handle LOAD BYPASSED TO NORMAL Load Break Contacts Load Break ATS ATS X NORM NORM NORM NORM ISOLATE Load Break Contacts Load Break Contacts Load Break Contacts Load Break Contacts Load Break Contacts Bypass Handle Bypass Handle AUTO AUTO BPN BPE Load Momentarily Disconnected Load Momentarily Disconnected Load Momentarily Disconnected BPN BPN BPN BPE BPE Bypass Handle Bypass Handle Bypass Handle Bypass Handle Bypass Handle Bypass Handle Bypass Handle Bypass Handle Emergency Power Available LOAD LOAD LOAD LOAD BYPASSED TO NORMAL LOAD BYPASSED TO NORMAL LOAD BYPASSED TO NORMAL Switch Bypassed to Emergency NORMAL EMERGENCY EMERGENCY EMERGENCY

Failsafe Bypass Switches (Where simplicity of operation is critical during an emergency condition) Load Contacts Diagram showing a normal operating state.

Failsafe Bypass Switches Bypass operation Load Contacts Bypass Handle

Failsafe Bypass Switches Bypassing to normal Load Break Contacts Bypass Handle Load Momentarily Disconnected

Failsafe Bypass Switches NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO Isolating the ATS Portion LOAD BYPASSED TO NORMAL

Failsafe Bypass Switches NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO LOAD BYPASSED TO NORMAL NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO Isolating the ATS Portion LOAD BYPASSED TO NORMAL

Failsafe Bypass Switches NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO LOAD BYPASSED TO NORMAL NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO If the transfer switch portion is bypassed & isolated to normal. If the normal power fails an engine start signal will initiate... LOAD BYPASSED TO NORMAL

Failsafe Bypass Switches NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO LOAD BYPASSED TO NORMAL NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO If the transfer switch portion is bypassed & isolated to normal. if the normal power fails an engine start signal will initiate... LOAD BYPASSED TO NORMAL

Failsafe Bypass Switches NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO Emergency Power Available LOAD STILL BYPASSED TO NORMAL

Failsafe Bypass Switches NORMAL LOAD EMERGENCY NORM ISOLATE ATS BPN BPE AUTO Switch Bypassed to Emergency

Failsafe Bypass Switches Should Normal Source return switch can still be racked in…

Failsafe Bypass Switches ATS RTB(D) - Load Break design (Break-Before- Make Bypass) NORM ISOLATE AUTO BPN BPE BPN BPE Should Normal Source return switch can still be racked in… LOAD NORMAL EMERGENCY