Sample Preparation Electron Microprobe samples must be: 1) Solid 2) Flat 3) Well polished (1 micron polish or better) 4) Low vapor pressure 5) Conductive.
Chapter 6: MICROTOMY Learning Objectives:
Anodic Aluminum Oxide.
Flexographic Tapes 3M Industrial Business 3 3M™ Cushion-Mount™ Plus Tapes with Easy Mount Adhesive.
Sample Preparation and Mapping Steps –Cleaning and drying of bulk samples –Initial Preparation. Cutting, impregnation, cast- making, fusing –Mounting.
V Cleaning Optics Includes excerpt from “The Clean Microscope” ( > Support > Download Center.
What are you looking for? Topography? –Is the surface dirty? –Are you looking for the clean surface or the dirt? –If the dirt, no preparation is required!
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Sample Preparation or Sample Prep. Always Handle samples with GLOVED HANDS!
O RBIS — Micro-EDXRF System. XRF Advantages Non-destructive: No beam damage or coating of sample Minimal Sample Preparation: conductivity not required.
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Meteorite 101 Cutting, Surface Preparation, Etching, and Preserving Iron Meteorites Prepared for AOAS By Leonard Lynch.
General Semiconductor Packaging Process Flow
Basic Screen Printing Procedures for T-Shirts GOP_5-2 Screen Printing.
Quantitative Analysis Quantitative analysis using the electron microprobe involves measuring the intensities of X-ray lines generated from your unknown.
I.C. Technology Processing Course Trinity College Dublin.
Metallographic Sample Preparation and Examination Prepared by: Mahmoud R.M.Abusrea Teaching Assistant, MDP Dept. October,2008.
Microscopes SC.912.L.14.4 Compare and contrast structure and function of various types of microscopes.
Production Decisions Chapter 6 Mr. Higgins. Objectives Identify the need for a plan of procedure Identify the need for a plan of procedure List the steps.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Preparation of cross-section TEM specimen on sapphire substrate
Conventional SEM Specimen at high vacuum – requires sample fixation and dehydration or freezing. Charging is minimized by coating sample with metal or.
SEM Scanning Electron Microscope
Principles of Manufacturing Copyright © Texas Education Agency, All rights reserved 1.
MPRI Centralised Laboratories Gerrard Peters School of Physics 1.
IDdesign Academy MORE EDUCATION – MORE KNOWLEDGE – MORE SALES Leather 1 Furniture leather.
Polypterus senegalus SEM Imaging Sample Preparation Protocol Sample Imaging Parameters -Scales were embedded in resin and cured at 60˚ C for 16 hours -Embedded.
Dye Solar Cell Assembly Glass handling Titania deposition Sintering process Sensitizer impregnation Platinum deposition Sealing electrodes Electrolyte.
Geochemistry of Pyrite and Whole Rock Samples from the Getchell Carlin –type Gold Deposit, Humboldt County, Nevada Tim A. Howell and Jean S. Cline University.
Scanning Transmission Electron Microscope
PENETRANT TESTING. Non Destructive Inspection Red Dye Penetrant Fluorescent Dye Penetrant Eddy Current Magnetic Particle X Ray Ultrasound.
Clay A mixture of different types of clays and minerals for a specific ceramic purpose.
The hot dip galvanizing process
Mohammed Zeeshan BT/PE/1601/ Microtexture: Electron Diffraction in the SEM Texture And Microstructure & Anisotropy.
Holders and Pumps Summary
Tools of a Scientist and Introduction to the Microscope
Jerky.
Preparation Stationary Sample Holders
Activities: G. Carotenuto
SAND CASTING.
Exp.1: Preparation of Specimens for Metallographic Examination
Manufacturing Process 1 Abrasive Machining Prepared By : Joshi Shubham H. ( ) GUIDED BY: PROF V N BADRAKIA SIR Presentation slide for courses,
Grinding Grinding is a process which utilizes the use of abrasive particles bounded together to produce superior surface finishing An abrasive: is a small,
PVCu SPRAYING.
Chemical and Electro-Chemical Energy Based Processes
Chemical and Electro-Chemical Energy Based Processes
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
METALLURGICAL MICROSCOPE
THE DEMINERALIZATION IMPACT ON MORPHOLOGY AND COMPOSITION
Module 9: Microscope Maintenance
Antirust Properties of Petroleum Products by NACE Corrosion
Excellence 80, Acczent Platinium 100 Tapiflex Essential 50,
Preface: What’s EPMA all about? How does Geology 777 work?
Electron Probe Sample Preparation The Hebrew University of Jerusalem
Preparation of Samples
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Preparation of Specimens for Metallographic Examination
CLEANING VALIDATION FOOD & BEVERAGE –– WASTEWATER –– LABORATORY –– PHARMACEUTICAL & MEDICAL DEVICE.
Cell Biology Practical TEM&SEM
GLAZING 101 Ceramics 1.
Insulators and Conductors
Do it with electrons !.
Using the Rilem Test Contents: Surface Preparation: Test Procedures:
VISUAL KEYS For Successful Base Material Preparation
Optical Metallography. Metallography is the study of the physical structure and components of metals, by using microscopy. Introduction.
Density = mass of rock/volume (kg/m 3 ) ρ= M t /V t Unit weight of solids =weight of dry rock/true volume (kN/ m 3 ) γs= W d /V s Relative density = density.
Electron probe microanalysis - Scanning Electron Microscopy EPMA - SEM
Scanning Electron Microscopy (SEM)
Presentation transcript:

Sample Preparation and Mapping Steps Cleaning and drying of bulk samples Initial Preparation. Cutting, impregnation, cast-making, fusing Mounting. Stubs, embedded samples, thin sections, grain mounts Polishing. For quantitative analysis Cleaning Mapping Coating Handling and storage

Preparing Bulk Samples Initial Prep: Remove organic material with oxidizing agent such as K-permanganate or H2O2 Rinse sediments or soils to remove soluble salts and fines if desired Carbonate can be removed with HCl Remove hydrocarbons by soaking in trichlorethane

Drying: Wet samples must be oven- or freeze-dried before introduction into the instrument. Be aware that temperatures of over 50oC can remove structural water from clay minerals. Rock samples that have been cut using a saw should be thoroughly dried prior to mounting.

Initial Preparation Cutting Large samples must be cut to thin-section size, or cut or broken to a appropriate size for an SEM stub. Typically, diamond-blade circular saw is used. Friable samples may need to first be impregnated. Impregnating Friable or porous samples should be vacuum impregnated prior to sample prep. Loose material on the sample surface can cause contamination of the electron column, and unimpregnated porous samples can cause poor vacuum by prolonged outgassing. Cast-making SEM visualization of pore structure can be facilitated by vacuum impregnating a sample, followed by dissolution of the sample material using hydrofluoric acid. Topographic details of small fossils can also be facilitated by producing latex cast Fusing Bulk analyses of fused rock samples can be made using EMPA techniques. Samples and standards should be fused using the same procedure.

Mounting SEM Stubs: SEM samples can be mounted onto Al or C stubs. C can be used for low X-ray background in the case of particulate analysis. Mounting can be done using epoxy, quick-setting glue, double-stick tape (mostly for particulates) or wax. Small grains can be mounted onto double-stick tape or partially dried carbon or silver paint.

Quantitative Analysis Preparation Embedding, Thin Section, Grain Mounts These are the most common techniques for preparation of geological samples.

Sample holders

Polishing Polishing a sample to a flat, unscratched surface is CRITICAL for good quantitative analysis. An uneven, or scratched sample surface can lead to uneven production of x-rays from the sample surface, errors in absorbtion correction, and spurious results.

Polishing The polishing steps needed for a sample depends on the types of material present. Metallic phases typically polish very easily, whereas minerals with strong cleavage can be problematic. A typical polishing procedure would be as follows: Grinding the sample to a flat surface, using 100, 260, and 600 mesh grit diamond wheels, or equivalents. Wash sample in water Polishing the sample using 30 micron diamond grit (600 mesh) for 3 minutes. Ultrasonically clean sample in deionized water Polish the sample using 6 micron diamond grit for 3 minute Polish the sample using 1 micron diamond grit for 3 minutes Polish the sample using 0.5 micron diamond grit for 1 minute

Cleaning Any contaminating material, particularly skin oil, on the sample surface will end up contaminating the column. Also, contaminating material under the conductive coating of a sample can cause the conductive coating that will be placed on the sample to bubble and crack, making the sample impossible to analyze KEEP THE SAMPLE CLEAN AND OIL FREE!!! 1. After final polish, clean the sample ultrasonically with deionized water 2. Wipe the sample surface with petroleum ether. 3. Following the petroleum ether cleaning, handle the sample as carefully as possible. Glove handling is ideal, but often inconvenient. An alternative is to handle the sample with a kimwipe, or other lint-free papr or cloth. 4. Blow the sample off with air prior to coating.

Mapping Finding analysis areas on a sample using the optical microscope or electron imaging can be difficult because of the small field of view. The maximum optical field of view for our instrument is 1750 microns (1.75 mm), and the maximum electron image field is around 2500 microns (2 mm). So, having a good sample map, particularly for quantitative analysis, is very important. Sample mapping is much less important for SEM work. Two types of map may be useful, depending on you sample. 1. Macro-map. Map of entire section. Depending on sample type, this may be hand-sketched, made with a slide copier, or with an enlarging xerox machine. 2. Micro-map. Map of areas of analytical interest. This needs to be produced with a camera-equipped microscope, and can be used to locate and document exact analytical spots. A micromap can also be produced using the microprobe. You can also mark areas of interest on your sample, but this must be done on a clean sample surface prior to applying the conductive coat.

Sample Coating Many geological samples are nonconductors of electricity. Therefore, if an uncoated sample is placed in the path of the electron beam, the sample will charge, causing deviation of the electron beam, as well as catastrophic decharging. The sample must be coated with conductive material, such as carbon, gold, or gold-palladium alloy. CARBON: For quantitative analysis and X-ray mapping, carbon is the coat of choice. Because of its low Z, it has a minimal effect on the X-ray spectrum, either in terms of producing X-ray lines or absorbing X-rays. A carbon coat is applied using a vacuum evaporator at pressures of less than 10-4 torr. The ideal coating thickness is 20 nm. GOLD: Gold can be a better choice for SEM coating because of its higher secondary electron yield.