Application note # QAN-0058 CHROMATOGRAMS FLOW RATE: 1.0 mL/min

Slides:



Advertisements
Similar presentations
Gas Chromatography.
Advertisements

Chromatographic Process Provides the analyte transport. Immobile phase. Mixture of components dispersed in the mobile phase.
Lecture 9 Yuri Kazakevich Seton Hall University
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
Analyte Ionization Lecture 3 Yuri Kazakevich Seton Hall University
11 Determination of the Levels of Fungicides on Citrus Fruits By Miseung Borgers Chem 4101, Fall 2008.
Evaporative Light Scattering Detector
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
Chromatography Year 12.
High Performance Liquid Chromatography High Performance Liquid Chromatography Chem. 331.
ENVIRONMENTAL ANALYSIS I. Solid Phase Extraction example - triazines.
Introduction to High Performance Liquid Chromatography.
Created with MindGenius Business 2005® Performance parameters (Advanced) Theoretical Plate Model Performance parameters (Advanced) Theoretical Plate Model.
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
PHASED: a Faster, Smarter & More Affordable Analysis Device - Update U.Bonne, J.Detry, R.Higashi, K.Newstrom-Peitso, H.Pham,
Varian 920-LC Integrated Analytical HPLC
Simple Scale-up on a 940-LC Analytical to Preparative HPLC
Comparison of Competitors’ Evaporative Light Scattering Detectors
The Use of Evaporative Light Scattering Detection in Pharmaceutical Analysis 1.
Nano Quantity Analyte Detector (NQAD) A New Aerosol-based HPLC Detector February 2008.
Summary of Analytical protocols used for Dye and organic pigment analysis Maarten van Bommel.
First Impressions Compact, modern design Flat top Small footprint, stackable Operation via control panel and simple keypad Column connection at front of.
Intensive General Chemistry Chemical separations II Isabelle Vu Trieu
Determination of ochratoxin A in wine by means of immunoaffinity column clean-up and high-performance liquid chromatography Ochratoxin A (OTA) Toxicity.
PL-ELS 2100 Ice. PL-ELS 2100 Ice Evaporation at Sub Ambient Temperatures The PL-ELS 2100 Ice comprises an Integrated Cooled Evaporator in combination.
E q u i p m e n t and chemicals HPLC (High Pressure Liquid Chromatography): C18 column Settings: 280nm, 2.5mL/min (4000psi), isocratic conditions (10.
HPLC – High Performance Liquid Chromatography
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
Midwest AOAC, St. Paul, MN, June 10, 2003
HPLC.
Chapter 28 High Performance Liquid Chromatography.
HPLC 1. Introduction 1.Introduction  INSTUMENTAL ANALYSIS  PRACTICAL 213 PHC  HPLC.
Comparison of the Varian 920-LC with Agilent 1200 Series HPLC.
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
Gas Chromatography Gas Chromatography Effendy De Lux Putra.
Forensic Toxicology Use Only Analysis of ETG, ETS using the Thermo Scientific Exactive Mass Spectrometer Kent Johnson Fortes lab, Portland Oregon.
Experiments in Analytical Chemistry
Chapter 5 – Organic Analysis
Column# m x 2.0mm 80/100 ShinCarbon ST
Overview Determining Identity Quantitative Analysis
QuEChERS Tubes Compounds : Aldicarb Oxamyl Methomyl Diuron Carbaryl
QuEChERS LRC Cartridge
Determination of Algae Compounds in Drinking Water
Functional group: ADME
Figure 1. Typical structure of polysorbate 80.
For Forensic Toxicology use Only
LC-MS/MS Analysis of Tetracycline antibiotics in Honey using Advance UHPLC-EVOQ™ SIMA LAB PVT LTD.
A sensitive and repeatable method for characterization of sulfonamides and trimethoprim in honey using QuEChERS extracts with Liquid-Chromatography-Tandem.
Agility WCX SPE Cartridges
High Performance Liquid Chromatography HPLC
Determination of Vismodegib by
HPLC.
HPLC Equipment : Detectors
Clinical Research Use Only Not For Diagnostic Purposes
Introduction 3. Instrumentation 2. Objectives 4. Results
The Right Solution: The Agilent 1200 Infinity Series for LC Analysis
HPLC.
Satish Pradhan Dnyanasadhana College, Thane (W)
High Performance Liquid Chromatography
Application note # QAN-0085 ™ APPLICATION NOTES CHROMATOGRAMS
APPLICATION NOTES THE NQAD IS HIGHLY SENSITIVE,
Aspartic acid racemization reveals a high turnover state in knee compared with hip osteoarthritic cartilage  J.B. Catterall, R.D. Zura, M.P. Bolognesi,
SEE LOWER CONCENTRATIONS WITH THE NQAD DETECTOR
High Performance Liquid Chromatography
Application note # QAN-0090 ™ APPLICATION NOTES CHROMATOGRAMS
Levofloxacin structural formula
Selvadurai Muralidharan, Jayaraja kumar, Venugopal Vijayan
Darrell Clinton and H. Dorota Inerowicz Purdue University
Fig. 6. HPLC analysis of RP key components
Damiana Gentili Qualified Person/QU Director 09/05/2019
Presentation transcript:

THE NQAD IS HIGHLY SENSITIVE, ALLOWING MORE SAMPLE COMPONENTS TO BE DETECTED Application note # QAN-0058 CHROMATOGRAMS FLOW RATE: 1.0 mL/min COLUMN: Thermo BetaBasic C18, 150 x 4.6 mm, 5u COLUMN TEMP: Ambient INJECTION VOLUME :10 µL ANALYTE: Hydrocortisone NQAD GAS: Air FILTER: 1.3 sec GAIN: 1X EVAPORATION TEMP: 35C ELSD GAS: Nitrogen, 1.5 L/min GAIN: 1 EVAPORATION TEMP: 40C HPLC MOBILE PHASE: 45:55 water:ACN PARAMETERS 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 4.00 9.00 mV min 1 NQAD, 10 ng Avg S/N, 53.5 APPLICATION NOTES 2 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 45.00 48.00 mV min 1 ELSD, 10 ng Avg S/N, 2.8 Demonstrates better sensitivity than ELSD ™ QUANT TECHNOLOGIES, LLC 1463 94TH Lane NE Blaine, MN, USA 55449 763-398-0508 www.Quant-NQAD.com 2 1 = Injection Artifact, 2 = Hydrocortisone, 10 ng 1