Distribution Workgroup 8 August 2012 Joanna Ferguson

Slides:



Advertisements
Similar presentations
1 Project Smart Metering Portfolio Foundation & DCC Day 1 Updates April 2013.
Advertisements

Gas Consumer Forum Project Nexus xoserve update 27th July 2009
1 Project Smart Metering Portfolio Foundation Updates June 2013.
1 Modification 422 Creating the permission to release data to Meter Asset Provider organisations A presentation by the Community of Meter Asset Providers.
1 Project Nexus Requirements Definition Phase Steve Nunnington.
1 Smart Metering Portfolio DCC Day 1 Project Smart Metering Portfolio Focus Group Project Update Thursday 06 th June 2013.
1 Project Nexus Data Management Definition Workshop 18 th May 2009.
PN UNC Workgroup Supply Point Register 25 th October 2011.
IGT Single Service Provision Requirements Update – 27 th March 2013.
CSEPs Reconciliation “Read Window” proposal. 2 Background  I&C CSEPs (supply point AQ >73,200) are subject to reconciliation  IGTs are obliged to provide.
PN UNC Workgroup iGT Services 7 th February 2012.
ROM and DCA. Scene setting Our house Our aspiration for our house Our project manager Us.
1 Modification 437 – Blank MAM Identities Distribution Workgroup December 2012.
1 New proposal extending the services created by Modification 279 historic asset and read data Modification 279 created an annual report (on request at.
1 Smart Metering Foundation Stage February Agenda File Format Changes for Effective Switching Back Population Approach for Effective Switching.
1 UNC Review Group 175 – Encouraging Participation in the Elective Daily Metered Regime 26 th June 2008.
13 th July 2009 Meeting of Theft of Gas Review Group (UNC245)
ADD PRESENTATION TITLE HERE (GO TO: VIEW / MASTER / SLIDE MASTER TO AMEND) ADD PRESENTER’S NAME HERE / ADD DATE HERE © Copyright EDF Energy. All rights.
Industry Dialogue on xoserve Services 14 th September 2007.
IGT and Shipper Workgroup meeting 28 th February 2011.
DCA timeline and ROM Overview 12 October Smart Metering Indicative Timeline Evaluation Service (EVS) 2528 received / Rough Order of Magnitude.
1 iGT Agency Services migration considerations As part of UK Link replacement programme (incorporating industry requirements) the new systems will need.
DSC Change Committee UK Link Future Releases Proposed Approach
User Pays User Committee 12th November 2013
Supply Point Register 7th December 2011
Supply Point Register 21st November 2011
Supply Point Register 10th January 2012
Modifications iGT 039 and GT 0440 re iGT Agency Services background
Distribution Workgroup 24/11/16
PN UNC Workgroup Invoicing 4th October 2011.
UNC Modification 0663S Extending the data comprised under the definition of Supply Point Premises Data (TPD V5.18.1) and iUNC Modification 114 Extending.
Meter Status Table Providing timely opening reads is an obligation to the confirming shippers. However where the confirming shipper fails to meet this.
Smart Metering Consequential Changes
Mod 430 iGT Mod 047 Workgroup Update
Agenda Action Review Update on IX and iGT access Testing strategy
iGT Agency Services Background
PN UNC Workgroup iGT Services
Assignment Workshop 2 16th September 09, Solihull.
DSC ChMC CSS update 7th November 2018
Project Nexus Workgroup
Project Nexus Workgroup
CSS Update for CoMC 19th September 2018
Modification 0468 – Unique Property Reference Number by Gas Transporters David Addison.
0630R Review Group meeting 21 February 2018 Settlement Data topic
CoMC on 20th February 2019 For Discussion Only
Topic raised at July 2009 Distribution Workstream
Smart Metering Portfolio DCC Day 1 UK Link Committee DCC Day 1 Shipper File Format Representation Thursday 08th August 2013.
Industry Shipperless & Unregistered Working Group
CSS Consequential Change CoS Shell Record Submission for Discussion at 630R 27th April 2018.
Project Nexus Workgroup
PN UNC Workgroup iGT Services
5 September 2012 Joanna Ferguson
Proposer: Debbie Brace Panel Date: 20th March 2014
Development modification group 194
Development modification group 194
M Number Creation process
PN UNC Workgroup iGT Services
Development modification group 194
Project Nexus Workgroup
Procurement of NDM profiling data
Development modification group 194
Gas Customer Forum Project Nexus xoserve update (as of 19th July 2010) 26th July 2010 Final.
Smart Metering Implementation Programme January 2013
DSC ChMC CSS update 12th September 2018
Meter Read Rejections ..
Project Nexus Workgroup
Modification 440 Project Nexus iGT Single Service Provision
Customer Issue Management CoMC Update
Development modification group 194
Customer Issue Management CoMC Update for June 2019
Presentation transcript:

Distribution Workgroup 8 August 2012 Joanna Ferguson Modification 0430 – Inclusion of data items relevant to smart metering into existing industry systems Distribution Workgroup 8 August 2012 Joanna Ferguson

Overview DECC Smart Metering Implementation Programme (SMIP) business process deign group (BPDG) identified requirements for Data Communications Company (DCC) access control DECC consequential changes group and Smart Working Issues Group (SWIG) refined requirements into code changes Changes identified to UNC, iGT UNC and SPAA UNC 0430 raised by NGN iGTUNC 047 raised by ES Pipelines SPAA changes to follow

UNC 0430: The Data Items Obligate shippers to pass specific data relevant to smart metering to GTs – new data items SMS Operator Entity & effective from date DCC Service Flag & effective from date IHD Install Status & effective from date* Unique Property Reference Number (UPRN) Changes to existing data items Smart Meter Installing Supplier: can be derived Meter Type: use new allowable items for Meter Mechanism Code Back to back changes identified to iGT UNC * Subject to DECC decision

UNC 0430: Permissions - Shipper Provide permission for GTs to provide data to relevant parties Shipper (on change of supplier) for each MPRN All existing data items on current flows Meter Type (Meter Mechanism Code) SMS Operator Entity & effective from date DCC Service Flag & effective from date IHD Install Status & effective from date * Smart Meter Installing Supplier ID UPRN (where known) * Subject to DECC decision

UNC 0430: Permissions – DCC Data Communications Company for access control purposes MPRN Supplier ID & effective from date MAM ID & effective from date Meter Point Address Meter Point Postcode UPRN (where known) Meter Type (Meter Mechanism Code) GT ID Market Sector Flag

Xoserve ROM Includes data collection from shippers, storage including iGT data & playback to shippers on Change of Supplier and to DCC for access control Communications infrastructure costs for Xoserve-DCC & Xoserve-iGTs not included Costs associated with increased volume of data submissions not included or assessed Delivery 44 - 62 weeks. DCA to refine requirements beneficial £600k - £1m with full UPRN a further £500k - £1m

Next Steps Co-ordination with iGT 047 Refine data transfer requirements DECC decision on inclusion of IHD data items still under review Agree User Pays allocation between shippers Request a DCA to refine Xoserve requirements, costs and timescales NGN to consider legal text options

UNC Modification 0430 Questions?