Laboratory: A Typical Evaporation Process
- Open evaporator.
- Remove wafer holder.
- This is where the wafers will be during the evaporation process.
- Remove the bell jar.
- Prepare metal: e. g., use metal wire.
- The metal will be placed in a "basket".
- Some evaporators use a "coil" instead of a "basket".
- Both metal and basket/coil should be cleaned.
- They should then be dried in the dehydration oven.
- The basket/coil should be installed between the two electrodes, and the metal placed inside the basket or around the coil.
- Move shutter to cover the filament.
- Put on the bell jar.
- Carefully load the wafers onto the wafer holder.
- One of the wafers may be a "test" wafer for measuring the metal layer thickness.
- Replace the wafer holder back on top of the bell jar.
- Place the cover back onto the bell jar.
- Lower pressure ( ~ 10-6 Torr ).
- Heat the filament to evaporate the metal.
- Cool and remove wafers.
- The test wafer allows measurement of film thickness.