PecConfig March 17th, 2015 Cathy Ding

Slides:



Advertisements
Similar presentations
Managing Your Site – Lesson 61 Managing Your Site Lesson 6.
Advertisements

1 After completing this lesson, you will be able to: Create a database. Create a table using the Table Wizard. Create and modify a table in Design view.
Getting Started with Cadence Compiled by Ryan Johnson April 24, 2002  Open Orcad Capture under Engineering Software  Under FILE, choose NEW, PROJECT.
Getting Started with Cadence Prepared by Ryan Johnson, 2002  Open Orcad Capture under Engineering Software  Under FILE, choose NEW, PROJECT  The following.
DHP-306AV & DHP-W306AV. Agenda: How to change Encryption on a DHP-306AV How to change the Device Password on a DHP-306AV What will happen if the Device.
MZ790 Print Driver and RINC Software Install and Setup These instructions are to assist you in installation and setup of the MZ790 Print Driver and RINC.
This example is a step by step walkthrough for installing the SRH Front Desk Printer in Windows 8.
Windows Tutorial 9 Maintaining Hardware and Software
TAX-AIDE Network Router Setup Network Printer Setups July SMT/TCS Training - Dallas1.
Ch 8-3 Working with domains and Active Directory.
One to One instructions Installing and configuring samba on Ubuntu Linux to enable Linux to share files and documents with Windows XP.
MagicInfo Pro Server Software All control, content, and scheduling is performed within the MagicInfo Pro Server software previously installed. Before.
Connecting to USF Network for Web Site SSH Secure Shell is the FTP program you will use to download your http files onto the USF server. To get the SSH.
COMPREHENSIVE Windows Tutorial 9 Maintaining Hardware and Software.
IT 211 Project Integration and Deployment Lab #11.
Copyright © 2007, Oracle. All rights reserved. Managing Concurrent Requests.
MagicInfo Pro Scheduler Now that a template has been created from content imported into the Library, the user is ready to begin scheduling content to.
Network Management Tool Amy Auburger. 2 Product Overview Made by Ipswitch Affordable alternative to expensive & complicated Network Management Systems.
Computing Fundamentals Module Lesson 3 — Changing Settings and Customizing the Desktop Computer Literacy BASICS.
Screenshots of the E-book download For Windows and Flash disks.
Version How to Use Packet Tracer MarinaMD.
Macromedia Dreamweaver 8-- Illustrated Introductory 1 Macromedia Dreamweaver 8 Unit B Creating a Web Site.
1 of 5 This document is for informational purposes only. MICROSOFT MAKES NO WARRANTIES, EXPRESS OR IMPLIED, IN THIS DOCUMENT. © 2007 Microsoft Corporation.
line.net/ okpop.com/bar elythereflashin dex.html.
1 Double Click to Edit. Installing Evernote 22 First, download the installation software. Open your favorite web browser and visit the Evernote Web site.
XP New Perspectives on Microsoft Office FrontPage 2003 Tutorial 7 1 Microsoft Office FrontPage 2003 Tutorial 8 – Integrating a Database with a FrontPage.
* DataSpace. * What is DataSpace * DataSpace is a third party add-on to ArcGIS Desktop * Developed by US Bureau of Reclamations * Allows the user to arrange.
Double –Click on the Netscape Icon on your desktop The following are a series of steps to help you get started with Netscape Composer.
A guide to file sharing on Windows XP Peer to Peer File Sharing.
1 /17 Installing and Configuring TaxWise © 2006, Universal Tax Systems, Inc. All Rights Reserved. Installing and Configuring TaxWise Objectives –In this.
* DataSpace is a third party add-on to ArcGIS Desktop * Developed by US Bureau of Reclamations * Allows the user to arrange data without actually moving.
Associate ® Administration An Associate administrator has the ability to change the parameters for both the author and for the typist. There can be enterprise.
Active-HDL Server Farm Course 11. All materials updated on: September 30, 2004 Outline 1.Introduction 2.Advantages 3.Requirements 4.Installation 5.Architecture.
5/14/2003Sprint TekNet IP Train the Trainer1 Open TekNet Software If working at a client station, enter the IP address of the server and mark page as a.
Basic Web Design UVICELL Week 4 Templates and site management Week 4 Templates and site management.
SOP of Setting up Automatic Startup of PecStar November 2013.
SOP of Transferring PecStar Database October 2013.
Configure the intercom IP
PMC-680i web interface Sep.9th 2016.
Computer Literacy BASICS
SOP of the Third-party Devices Configuration
The first change to your project files that is needed is to change the device to the correct FPGA. This is done by going to the Assignments tab on the.
1.0 COMPUTER NAME & WORKGROUP SETTING
Chapter A - Getting Started with Dreamweaver MX 2004
Receiving New Lending requests
Wireless Network Access on Mac OSX
3.14 Microscan QX-870 Scanner Configuration
3.1 Profibus Card Driver Installation
Pilot Pioneer Operation Guide v9.6
T_C_N_L_G_ E D I D I E O Y O H I E B J I R E A A W.
Creating a Windows 7 Professional SP1 Virtual machine
1. Press the Power button or switch to flip on the printer, if it is turn off. 2. From the Home display screen on the product control panel, click the.
ALEPH Version 22 Beginning Cataloging
Dreamweaver CS4 Skills PLAN – PLAN – PLAN first
EndNote by: fatimah alotaibi.
Inovonics Wireless Corporation
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Windows Tutorial 9 Maintaining Hardware and Software
Configuration Of A Pull Network.
Software Setup & Validation
Switching & Controlling LoB
How to Change Y-axis of Trending Curve
SOP of Configuring Auto-mail Alarm
SOP of System Security Settings
SOP of Reset Maximum Demand
Setting up DWService to access a remote CAMS computer
Java Code Review with CheckStyle
RapidFinder Analysis Software How-To Guide
OWS + SureView Integration
How to install and manage exchange server 2010 OP Saklani.
Presentation transcript:

PecConfig March 17th, 2015 Cathy Ding International Business Department

Content Content Communication Settings Energy Measurement Settings Question & Answer Power Quality Settings Energy Measurement Settings Communication Settings Content

PecConfig Power Quality Settings Energy Measurement Definition Communication Setup Energy Measurement Definition Power Quality Settings Logic Layer: PQ Group PQ Node Link Device V Nominal Harmonic Limit Logic Layer: Energy Group Energy Node Link Device Energy Source Demand Source for PQ Analyzers Physical Layer: Station Site Device Data Point Datalog Source for Energy Meters

PecConfig Communication Settings Starting PecConfig. Double-click the PecAssistant icon on the desktop and click PecConfig. Use Name: ROOT Password: Then click OK. Click Start > All Programs > iEMS V3.6 > System Configuration Module > PecConfig. Navigate to the D:\CET\Common folder, and double-click PecConfig.exe.

PecConfig Communication Settings Menu Toolbar 1 Display area 2 3 Setup Pane Status bar

PecConfig Communication Settings Add a Station. Click Station Setup, then click Node, the Communication Station Setup window appears. Input the Name and choose the corresponding Time Zone. Then click OK. 2 3 4 1 5

PecConfig Communication Settings Setup System Network. Click System Network, then double-click the node, the Properties window appears. Input the Name, Computer, IP. Choose the Node Type and Station. 1 2 3 The node referring to the local machine is created automatically after adding a station. 4 5 6 7 8

PecConfig Communication Settings Add a Site. Click Communication Setup, then click Node, the Site Properties window appears. Input the Site Name, chose the corresponding Driver Type, select the communication parameters according to the network and device settings. Example: Modbus Protocol, EtherGate 2 3 4 1 5 6 7 8 9

PecConfig Communication Settings Add a Device. Click the site, then click Node, the Device Properties window appears. Input the Device Name, Comm ID, choose the Device Type, Data Map and Waveform Map if available. Then click OK. 2 3 4 5 6 7 1 8

PecConfig Communication Settings Import SNF File. If the system does not import the .snf file automatically, we should do it manually. Select the device and right-click on it, choose Import SNF File from the pop-up menu, and choose the corresponding .snf file. The default .snf files are put under the \CET\Common\Context folder after the device drivers are installed. 1 3 2 4

PecConfig Communication Settings Enable Virtual Datalog if the meter does not have data recorders. Select the device and open Device Properties window, click Virtual Datalog>>. For example, PMC-53M does not support on-board datalogs. We can setup Virtual Datalog in PecConfig for software datalogs. 1

PecConfig Communication Settings Check Enabled and set the Saving Interval. Then choose the parameters you want to do software datalogs from the Para. Selection list, and click OK. 1 2 3 The Virtual Datalog settings will be applied to the same type of meters if check this option. 4

PecConfig Communication Settings Verify Datalog settings. Click Data Map>> from the Device Properties window. All datalog parameters will be listed in the window. The Code of Virtual Datalog starts from 10,000,000. 2 PMC meters have default data maps. You need to setup the meter’s data recorders correctly before communicating with the meter by iEMS. 1

PecConfig Communication Settings Enable Virtual Datalog if the meter does not have data recorders. Click Energy Management Definition, then click Node, the Energy Group Properties window appears. Input the Name of the energy group. Then click OK. New Old 1 TOU Energy Setup: Used for energy billing management. TOU Setpoint Setup: Used for demand management. When actual value exceeds the limits, the system will give an alarm. 2

PecConfig Communication Settings Save all the settings. Click OK when prompt ‘Save to database succeeded.’ 1 The Code of is pre-defined by the device driver. 2

Check Communication Status After the basic communication configuration is done, open PecSCADA (Front.exe) to check the communication. Note: Ensure that the DServer is running.

PecConfig Energy Measurement Settings Add an Energy Group. Click Energy Management Definition, then click Node, the Energy Group Properties window appears. Input the Name of the energy group. Then click OK. 2 3 1 4 Energy Management is used to manage logical node of energy consumption measurement via associating with devices and related parameters. You can statistic energy consumption for areas by creating Energy Group to divide areas.

PecConfig Energy Measurement Settings Add an Energy Node. Click the energy group, then click Node, the Select Node Type window appears. Select Energy Node and click OK. Then select the device from the Select Node window and click OK. 2 5 4 1 3 6

PecConfig Energy Measurement Settings Set Energy Source. The Energy Node Properties window appears. In the Energy Source tab, click Add, select the energy parameter from the Select Datalog window, then click OK. Select TOU Energy if you want to apply any TOU energy scheme for this device. 1 2 4 3

PecConfig Energy Measurement Settings Set Demand Source. In the Demand tab, click Add, select the demand parameter from the Select Datalog window, then click OK. Select TOU Setpoint if you want to apply any TOU setpoint scheme for this device. 1 2 4 3

PecConfig Energy Measurement Settings Set Predicted Demand Source. In the Demand tab, select a demand source and click Edit, the Edit Demand Para. Window appears. Click the … button and select the predicted demand parameter from the Select window, then click OK. 3 1 5 2 4 6

PecConfig Energy Measurement Settings After this configuration, PecStar iEMS will compare present demand with predicted demand. If (Present demand + Predicted demand) > Demand Contract Value, the system will alarm. 6. Save all the settings. Click OK when prompt ‘Save to database succeeded.’

PecConfig Power Quality Settings Add a Station. Click Station Setup, then click Node, the PQ Group Properties window appears. Input the Name and click OK. 2 3 4 1 Power Quality is used to monitor power quality events such as sag/swell, transient or harmonic setpoint events for logical node by associate with PQ devices. You should configure the Power Quality first and then query the PQ information in iEMS Web.

PecConfig Power Quality Settings Add an Energy Node. Click the energy group, then click Node, the Select Node Type window appears. Select PQ Nodes and click OK. Then select the device from the Select Node window and click OK. 2 2 5 4 1 1 3 6

PecConfig Power Quality Settings Set PQ Node. The PQ Node Properties window appears. Input the V Nominal. You can change the unit of voltage from V to kV by clicking the V toggle button. Click Add, select the harmonic parameter from the Select window, then click OK. 1 2 3 4 4

PecConfig Power Quality Settings Set Harmonic Limit. In the Harmonic Limit Settings list, select a harmonic source and click Edit, the Edit Parameter Window appears. Input the High Limit and Low Limit, then click OK. 1 2 3 4 5 The harmonic limit settings can be saved to Threshold.INI file and import from an existing file. 5

PecConfig Power Quality Settings iEMS V3.6 provides tolerance curve, including ITIC Curve and SEMI Curve, by monitoring disturbed voltage. Provides sag/swell event report and device setpoint report through monitoring voltage event. Also, iEMS V3.6 displays real-time waveform for device and you can compare harmonics. Save all the settings. Click OK when prompt ‘Save to database succeeded.’

Exercise Exercise: Connect a PMC-630A meter to your iEMS V3.6 system. Objectives: Able to setup virtual datalog Able to read realtime data from the PMC-630A meter in PecSCADA Able to show the energy nodes in iEMS V3.6 Web

Questions?