MEK-6400 series Technical seminar

Slides:



Advertisements
Similar presentations
January 2012International Medcom, Inc How to Use the Radalert 100.
Advertisements

January 2012International Medcom, Inc How to Use the Inspector Alert.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
TECHNICAL TRAINING Mini Chiller Panel Controller V2.0.
DEVELOPING ICT SKILLS PART -TWO
 Use the Left and Right arrow keys or the Page Up and Page Down keys to move between the pages. You can also click on the pages to move forward.  To.
01/05/2015 Input-Output-Process Demo Automatic Streetlight System.
MLAB 1415: Hematology Micros 60.
March 2005 International Medcom How to Use the Inspector.
March 2006 Berkeley Nucleonics Corporation How to Use the palmRAD 907.
1 Starting & Stopping Motors Pico Pico LAB#4. 2 Program a series of three basic ladder logic rungs. These basic rungs are the most common rungs found.
MEK-6400 series Technical seminar Sensors adjustment.
International Medcom How to Use the Radalert 50 March 2005 International Medcom
Settings & Adjustments. Settings & Adjustments.
PC Maintenance: Preparing for A+ Certification Chapter 17: Keyboards and Mice.
Introduction to Arrays. definitions and things to consider… This presentation is designed to give a simple demonstration of array and object visualizations.
GCS 300 System Operation Application – Level 1.
Automated Equipment LLC
TI – 83 Plus1 A Quick Reference Presentation for AMSTI Year 1 Training.
Entering your user ID into the NXT Clicker *Your User ID is your Netpass username.
© The McGraw-Hill Companies, 2006 Chapter 3 Iteration.
321 Calc! Login Instructions for Students. You will need the following items before logging into this course: An Access Code for 321 Calc! – You may have.
Parallel Circuits. In parallel circuits the current can take more than one path. We call these separate paths branches. The branch points are known as.
DATE Manual DS – DVR Tel : 82–32-462–6911
NORMA ICON. INTRODUCTION - ICON Point of care ready Small footprint Smallest sample volume and lowest reagent consumption in the world Microfluidic components.
Fundamentals of Windows Mouse n 4 Basic Operations: –Pointing –Clicking –Double Clicking –Dragging.
Add Video Library in Company
Add Media in Company After Login Below screen will display
Splash Screen.
Level Control Level control commissioning (System tab)
Quick Guide For sensors
CA05FS Owner’s Manual Fuel Cell Technology Breath Alcohol Tester.
You will get a menu as displayed on screen.
Presented by: JAHANGIR SHOKAT HUSNAIN ANSER.
International Operations
Instructions to Video Conferencing Rooms
اساس اندازه گیری در سل کانتر
Hemodialysis Lecture 3.
Micros 60 & Quality Control
ReverseTap S/W MANUAL.
Splash Screen.
Excel: Navigating the Screen
TOUCH SCREEN.
Epic Basic Appointment Scheduling Patient Preferences
Lamp Error reset Method to solve “Lamp Error” problem
Dismissal Staff Quick Start Guide
2) Connect the VGA cable from the monitor output of the laptop [D] to the computer input of the projector [E]. [D] [E]
Microsoft Office Illustrated Introductory, Windows XP Edition
The BioTector B3500ul TOC analyzer Process Tests
SAM Self Assessment Software
Automatic Test Station for GasAlertClip Extreme Portable H2S Monitors
Keypad / Display Rev. J -11/21/2018.
Windows xp PART 1 DR.WAFAA SHRIEF.
Input-Output-Process Demo
CANON Pixma G200 Canon's first refillable ink tank All-In-One printer is designed for high volume printing at low running cost. Features Highlight - Print,
Input-Output-Process Demo
How to PostPower Point Presentations
Input-Output-Process Demo
MEK-6400 series Technical seminar
Conference room user manual
CELL-DYN 1700/1800 Software Training Simulation
How to Use the Inspector Alert
Wavewin Sniffer 24 Configuration & Polling Software
MEK-6400 series Technical seminar
Electric Circuits Ch 17, section 4.
Two methods to observe tutorial
Sioux City Community Schools Computer System
MAINTAINING FILES AND CUSTOMIZING WINDOWS Section 2
Presentation transcript:

MEK-6400 series Technical seminar Sensors adjustment

Adjustment of the sensors MEK-6400 series have 1 HGB measuring sensor, and 6 liquid detecting sensors. HGB measuring sensor WBC manometer sensor ( High, Low ) RBC manometer sensor ( High, Low ) Diluent and detergent detecting sensor Lysing reagent detecting sensor This section is how to adjust these sensors.

Adjustment on screen 試薬マネージメントが出来ます。 Sensor voltage adjustment is available on the screen. (*)except HGB sensor voltage

HGB measuring sensor HGB Measuring sensor

Adjustment of HGB measuring sensor’s voltage There is a HGB sensor with a WBC measurement bath in measurement unit MC-640V. It is necessary to keep measurement reliability of HGB, the HGB sensor voltage should be adjusted around 3.0V in a state of HGB LED on. The sensor voltage has to be less than 0.5V in a state of HGB LED off. When the HGB sensor voltage is abnormal, “*” mark is displayed if the voltage is less than 0.5V when HGB LED is off. “!” mark is displayed if the voltage is more than 4.5V when HGB LED is on. “?” mark is displayed if the voltage is less than 1.5V when HGB LED is on. In such a case, the reliability of HGB results becomes lower.

Adjustment of HGB measuring sensor’s voltage Adjustment method of the HGB sensor in the following. Choose “OTHER” key from “MENU” screen. After that, choose “SENSOR MONITOR” function, so that you can see all sensors’ voltage on the screen.

Adjustment of HGB measuring sensor’s voltage Remove the side panel. Check the WBC measurement bath is filled by diluent. Turn the variable resistance of the HGB sensor voltage on UT-7201 ( HGB AMP BD, cf. illustration ) and adjust it so that the HGB sensor voltage becomes about 3.0V. HGB sensor VR

Adjustment of HGB measuring sensor’s voltage Check HGB sensor voltage in a state of LED On is about 3.0V ( this figure is bad case ) Check HGB sensor voltage in a state of LED Off is less than 0.5V After adjustment, replace the side panel.

WBC/RBC Manometer sensor WBC manometer (High) RBC manometer (High) WBC manometer (Low) RBC manometer (Low)

Adjustment of WBC/RBC Manometer sensors’ voltage Two manometers for WBC and RBC absorb diluted sample of 360uL from apertures in measurement unit MC-640V. Each manometer has two liquid surface detecting sensors, higher and lower sensor. In the state that manometer is filled by diluent, the manometers sensors voltage should be lower than 1.5V. In the state that manometer is empty, the manometers sensors voltage should be higher than 3.5V A device judges to be or not to be of water at 2.5V. But if sensor voltages are between 2.25V - 2.75V, device cannot detect liquid surface precisely. To keep measurement reliability, device displays alarm such as “Manometer dirty“

Adjustment of WBC/RBC Manometer sensors’ voltage To adjust the manometer voltages, you have to change the operator to “Factory” Choose “Setting” in “MENU”, and select “USERS“. Choose "Factory" and push “CHANGE" key to change the operator. You have to enter the password. Enter "4321“ as a password of "Factory".

Adjustment of WBC/RBC Manometer sensors’ voltage Adjustment method of the WBC/RBC Manometer sensors in the following. Choose “OTHER” key from “MENU” screen. After that, choose “SERVICE” function. Choose “MONITOR” key form “SERVICE“ screen, after that choose “Sensor monitor” function.

Adjustment of WBC/RBC Manometer sensors’ voltage Different point of two “Sensor monitor” screen, in normal menu and in service menu, is “INPUT CAL" key in service menu. To adjust the manometer sensor voltages, push "INPUT CAL" key and change coefficient factors.

Adjustment of WBC/RBC Manometer sensors’ voltage Displayed contents are as follows. WBC up: Upper sensor coefficient of WBC manometer WBC low: Lower sensor coefficient of WBC manometer RBC up: Upper sensor coefficient of RBC manometer RBC low: Lower sensor coefficient of RBC manometer

Adjustment of WBC/RBC Manometer sensors’ voltage Move a cursor with arrow key and put “ENTER” key after the input with numerical value. Push “OK” key to back to “Sensor monitor” screen, and check that the sensor voltage of manometers in filled by diluent is lower than 1.5V And check that the sensor voltage is adjusted more than 3.5V in the state that there is no diluent in the manometer. Repeat above operations till these voltages become reasonable values.

Diluent /Detergent sensor, Lysing reagent sensor

Adjustment of Diluent /Detergent, Lysing reagent sensor voltage MEK-6400 has two reagent detection sensors which for diluent / detergent detection, and lysing reagent detection in “Inlet and outlet unit JQ-640V”. Each liquid sensor voltage is less than 1.5V in a state to filled by reagent, and it is necessary to be adjusted than 3.5V in a empty state. A device judges to be or not to be of water at 2.5V. But if sensor voltages are between 2.25V - 2.75V, device cannot detect liquid surface precisely.

Adjustment of Diluent /Detergent, Lysing reagent sensor voltage Displayed contents are as follows. Diluent: Diluent and Detergent detecting sensor coefficient. Lysing: Lysing reagent detecting sensor coefficient of WBC manometer

Adjustment of Diluent /Detergent, Lysing reagent sensor voltage Move a cursor with arrow key and put “ENTER” key after the input with numerical value. Push “OK” key to back to “Sensor monitor” screen, and check that the sensor voltage in filled by reagent is lower than 1.5V And check that the sensor voltage is adjusted more than 3.5V in the state that there is no diluent. Repeat above operations till these voltages become reasonable values.